Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, AC & Plumbing Services in Akron, OH 44301

Akron 44301 has a housing history that shows up clearly once you step inside the mechanical room. Around Firestone Park and the surrounding South Akron districts, established homes include historic properties, classic mid-century houses, and vintage brick and frame construction. Some still have radiator-era heating layouts, while others have been converted to forced air and updated again over the years.

That variety creates service problems that are not always obvious from the thermostat or the age of the equipment. A furnace may be relatively new, but the ductwork behind it may be decades older. Central air may have been added long after the house was built, while plumbing upgrades may only cover one portion of the property. Lakes Heating & Air Conditioning works throughout Akron 44301 helping homeowners sort out those layers. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.

Firestone Park Homes Often Have More Than One Generation Of HVAC

Firestone Park is one of the defining neighborhoods in this part of Akron. Its history as Harvey Firestone's planned garden suburb gives the area a residential character that is very different from newer development farther outside the city.

Inside those homes, the mechanical systems often reflect decades of change. Traditional basements, older masonry, radiator systems, legacy ductwork, and later forced-air conversions all appear in 44301. One house may still rely on a boiler, while another nearby may have gone through several generations of furnace and AC replacements.

That history matters when comfort becomes uneven. The newest piece of equipment may be working correctly while an older part of the system limits what it can do.

Plumbing Repairs In South Akron Often Start In The Basement

Traditional basements are common throughout 44301, and they usually bring much of the home's plumbing and HVAC infrastructure into view. Water heaters, gas lines, drain piping, furnace equipment, and other utility connections often share the same lower-level space.

In an older brick or frame home, that basement can reveal how the property has changed over time. A newer water heater may connect to older piping. A remodeled bathroom may have updated supply lines while other sections of the home still rely on earlier plumbing.

Our plumbing services include:

  • Plumbing installation
  • Plumbing repair
  • Water heaters
  • Drain cleaning
  • Bathroom remodel plumbing
  • Faucet installation and repair
  • Leak detection and repair
  • Gas line installation
  • Garbage disposals
  • Toilets
  • Sinks
  • Sump pumps

A slow drain, changing water pressure, or leaking fixture can be more than an isolated nuisance. In an established South Akron home, it can be the first clue that one part of the plumbing is aging differently from the rest.

Radiators And Gas Furnaces Can Be Neighbors In 44301

The heating systems around Firestone Park and South Akron reflect the age of the housing. Some homes still rely on radiator heat, while others were converted to forced-air furnaces years ago. Mid-century properties are more likely to have conventional gas heating and familiar duct layouts.

Akron winters bring enough cold and snow to expose weaknesses quickly. A radiator system may develop uneven circulation, while a forced-air furnace may struggle because of blower performance, controls, or restricted ductwork.

Our heating services include:

Two homeowners can describe the exact same problem and need completely different repairs. A cold bedroom in a radiator-heated Firestone Park home may have nothing in common with a cold bedroom in a forced-air house only a few streets away.

Older Floor Plans Can Make Summer Cooling More Complicated

Warm, humid summers can expose the limitations of AC systems installed in houses that were never originally designed around central cooling. Vintage brick and frame homes in 44301 may have supply runs added through whatever routes were available rather than built into the original structure.

That can show up as warmer upstairs rooms, weak circulation in enclosed spaces, or an AC system that runs longer than expected. Mid-century homes with more conventional ductwork can develop their own problems as those ducts age or get altered during remodeling.

Lakes provides:

A high-efficiency outdoor unit can only improve comfort as much as the rest of the house allows. In 44301, summer performance often depends on whether the existing duct layout can actually deliver cooling evenly through an older floor plan.

The Towpath Side Of South Akron Brings Seasonal Air Changes Indoors

The Ohio & Erie Canal Reservation and Towpath Trail are familiar parts of the South Akron landscape. The surrounding green space reflects the seasonal conditions homeowners deal with throughout 44301, from humid summer weather to long stretches of dry indoor heat during winter.

Older enclosed floor plans can make those changes more noticeable. A house that has received new windows, insulation, or HVAC upgrades over the years may now hold air and moisture differently than it did when first built.

We install and service:

  • Air cleaners
  • Air scrubbers
  • Air purifiers
  • Humidifiers
  • Dehumidifiers
  • Thermostats
  • Carbon monoxide detection
  • Air ducts and ductwork

Filtration and air scrubbers can help manage indoor particles, while humidity control becomes more important as the seasons change. If one part of the house still feels noticeably different, circulation may be just as important as the air quality equipment itself.

HVAC And Plumbing Service For The Homes That Make South Akron Distinct

Firestone Park, the neighborhoods around the Ohio & Erie Canal Reservation, and the rest of 44301 were not built all at once, and their mechanical systems reflect that. Radiator heat, forced-air conversions, traditional basements, later AC installations, and updated plumbing all appear across this part of Akron.

Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44301. Call (330) 536-1276 or contact us online today to schedule service.

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026.

The most recent job was on October 21, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Performed fall heating maintenance on the natural gas furnace, including a flue gas combustion analysis showing 6.9% O2, 43.8% excess air, and 11 ppm CO (16 ppm air-free), all within acceptable operating limits. Inspected and serviced the return air filter, which showed moderate dust loading, to maintain proper airflow and system efficiency. Unit operation verified with no visible rust, frost, or damage observed.
Performed fall heating maintenance on the natural gas furnace, including a flue gas combustion analysis showing 6.9% O2, 43.8% excess air, and 11 ppm CO (16 ppm air-free), all within acceptable operating limits. Inspected and serviced the return air filter, which showed moderate dust loading, to maintain proper airflow and system efficiency. Unit operation verified with no visible rust, frost, or damage observed.
Zack W.
Zack W. Checked in
Performed fall heating maintenance on the natural gas furnace, including a flue gas combustion analysis showing 6.9% O2, 43.8% excess air, and 11 ppm CO (16 ppm air-free), all within acceptable operating limits. Inspected and serviced the return air filter, which showed moderate dust loading, to maintain proper airflow and system efficiency. Unit operation verified with no visible rust, frost, or damage observed.
Akron, OH 44319
Responded to a no-heat call on a Comfort-Aire gas furnace reported to have a buzzing noise and failure to cycle, with a suspected blower motor or control board fault. Inspected the inducer assembly, pressure switch, gas valve, and burner compartment, then restored operation with stable burner flame established. Verified performance with a combustion analysis on natural gas, recording 5.6% O2, 32.5% excess air, 27 ppm CO, and 37 ppm air-free CO, all within acceptable limits.
Responded to a no-heat call on a Comfort-Aire gas furnace reported to have a buzzing noise and failure to cycle, with a suspected blower motor or control board fault. Inspected the inducer assembly, pressure switch, gas valve, and burner compartment, then restored operation with stable burner flame established. Verified performance with a combustion analysis on natural gas, recording 5.6% O2, 32.5% excess air, 27 ppm CO, and 37 ppm air-free CO, all within acceptable limits.
Zack W.
Zack W. Checked in
Responded to a no-heat call on a Comfort-Aire gas furnace reported to have a buzzing noise and failure to cycle, with a suspected blower motor or control board fault. Inspected the inducer assembly, pressure switch, gas valve, and burner compartment, then restored operation with stable burner flame established. Verified performance with a combustion analysis on natural gas, recording 5.6% O2, 32.5% excess air, 27 ppm CO, and 37 ppm air-free CO, all within acceptable limits.
Akron, OH 44319
Akron, OH - Responded to a no-cool call on a 16-year-old gas furnace and performed a combustion analysis on the flue gas using a Testo 327-1 analyzer. Readings showed 6.0% O2, 35.8% excess air, 7 ppm CO, and 10 ppm air-free CO, all within acceptable operating limits for natural gas combustion.
Zack W.
Zack W. Checked in
Responded to a no-cool call on a 16-year-old gas furnace and performed a combustion analysis on the flue gas using a Testo 327-1 analyzer. Readings showed 6.0% O2, 35.8% excess air, 7 ppm CO, and 10 ppm air-free CO, all within acceptable operating limits for natural gas combustion.
Akron, OH 44301
Akron, OH - Performed fall heating maintenance on a natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable range, with O2 at 8.2%, CO2 at 7.1%, CO at 9 ppm, and steady-state efficiency of 88.1%. System operating normally at completion of service.
Maddex H.
Maddex H. Checked in
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable range, with O2 at 8.2%, CO2 at 7.1%, CO at 9 ppm, and steady-state efficiency of 88.1%. System operating normally at completion of service.
Akron, OH 44319
Akron, OH - Performed scheduled heating maintenance on a gas-fired furnace, including inspection of the unit and verification of proper operation. Conducted a combustion analysis using a digital analyzer on natural gas, recording O2 at 7.32%, CO at 7 ppm, and CO2 at 7.62%, with CO levels well within safe limits and indicating clean, stable combustion. No deficiencies were noted and the system was left operating normally.
Jake T.
Jake T. Checked in
Performed scheduled heating maintenance on a gas-fired furnace, including inspection of the unit and verification of proper operation. Conducted a combustion analysis using a digital analyzer on natural gas, recording O2 at 7.32%, CO at 7 ppm, and CO2 at 7.62%, with CO levels well within safe limits and indicating clean, stable combustion. No deficiencies were noted and the system was left operating normally.
Akron, OH 44319
Akron, OH - Performed a descale service on the power-vented Rheem tank water heater, flushing mineral and sediment buildup from the tank and discharging the flush water to the adjacent floor drain. Following the service, the unit, venting, and electrical connections were inspected, and no leaks, corrosion, or visible damage were found.
Triston Y.
Triston Y. Checked in
Performed a descale service on the power-vented Rheem tank water heater, flushing mineral and sediment buildup from the tank and discharging the flush water to the adjacent floor drain. Following the service, the unit, venting, and electrical connections were inspected, and no leaks, corrosion, or visible damage were found.
Akron, OH 44321
Installed shutoff valves on the gas piping serving a multi-meter manifold in the basement utility area, connecting flexible gas lines with brass fittings and red-handled isolation valves to each meter. Verified secure connections and proper valve operation at each meter location, with piping routed overhead to the meter bank.
Installed shutoff valves on the gas piping serving a multi-meter manifold in the basement utility area, connecting flexible gas lines with brass fittings and red-handled isolation valves to each meter. Verified secure connections and proper valve operation at each meter location, with piping routed overhead to the meter bank.
Triston Y.
Triston Y. Checked in
Installed shutoff valves on the gas piping serving a multi-meter manifold in the basement utility area, connecting flexible gas lines with brass fittings and red-handled isolation valves to each meter. Verified secure connections and proper valve operation at each meter location, with piping routed overhead to the meter bank.
Akron, OH 44303
Performed a scheduled commercial heating maintenance visit, inspecting the return air ductwork and verifying the 16x25x1 filter installation, which was found to be dated 10/19/21 and in need of replacement. Measured duct surface temperature at 126.3°F with a digital pocket thermometer to confirm heating operation, and checked the foil-taped duct seams, with no damage, frost, or rust observed.
Performed a scheduled commercial heating maintenance visit, inspecting the return air ductwork and verifying the 16x25x1 filter installation, which was found to be dated 10/19/21 and in need of replacement. Measured duct surface temperature at 126.3°F with a digital pocket thermometer to confirm heating operation, and checked the foil-taped duct seams, with no damage, frost, or rust observed.
Roderick H.
Roderick H. Checked in
Performed a scheduled commercial heating maintenance visit, inspecting the return air ductwork and verifying the 16x25x1 filter installation, which was found to be dated 10/19/21 and in need of replacement. Measured duct surface temperature at 126.3°F with a digital pocket thermometer to confirm heating operation, and checked the foil-taped duct seams, with no damage, frost, or rust observed.
Akron, OH 44312
Akron, OH - Performed seasonal fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer to verify safe and efficient operation. Flue gas readings were within acceptable parameters, with O2 at 10.5%, CO at 14 ppm, CO2 at 5.9%, and steady-state efficiency of 96.8%, confirming proper combustion and heat exchanger performance.
Maddex H.
Maddex H. Checked in
Performed seasonal fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer to verify safe and efficient operation. Flue gas readings were within acceptable parameters, with O2 at 10.5%, CO at 14 ppm, CO2 at 5.9%, and steady-state efficiency of 96.8%, confirming proper combustion and heat exchanger performance.
Akron, OH 44313
Akron, OH - Performed seasonal heating maintenance on a 22-year-old basement-installed natural gas furnace. Completed a flue gas combustion analysis with a Testo 327-1, recording 9.2% O2, 69.7% excess air, 2 ppm CO, and 4 ppm air-free CO, all within safe operating limits and confirming proper combustion performance. The unit is operating normally, and the customer is due for maintenance plan renewal.
Zack W.
Zack W. Checked in
Performed seasonal heating maintenance on a 22-year-old basement-installed natural gas furnace. Completed a flue gas combustion analysis with a Testo 327-1, recording 9.2% O2, 69.7% excess air, 2 ppm CO, and 4 ppm air-free CO, all within safe operating limits and confirming proper combustion performance. The unit is operating normally, and the customer is due for maintenance plan renewal.
Akron, OH 44320
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Brandon F.
Brandon F. Checked in
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Akron, OH 44333
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Roderick H.
Roderick H. Checked in
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Akron, OH 44319
Akron, OH - Performed annual heating maintenance on a natural gas furnace of unknown age, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a calibrated flue gas analyzer, recording O2 at 8.21%, CO at 4 ppm, CO2 at 7.13%, and combustion efficiency of 88.5%, confirming safe operation with CO well within acceptable limits and the system operating within normal parameters.
Jake T.
Jake T. Checked in
Performed annual heating maintenance on a natural gas furnace of unknown age, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a calibrated flue gas analyzer, recording O2 at 8.21%, CO at 4 ppm, CO2 at 7.13%, and combustion efficiency of 88.5%, confirming safe operation with CO well within acceptable limits and the system operating within normal parameters.
Akron, OH 44333
Akron, OH - Performed seasonal heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a gas analyzer that recorded O2 at 7.03%, CO at 12 ppm, and CO2 at 7.79%, confirming safe operation within acceptable parameters. Replaced the filtration components with one 213 media filter and one #35 water panel, and verified proper system operation upon completion.
Jake T.
Jake T. Checked in
Performed seasonal heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a gas analyzer that recorded O2 at 7.03%, CO at 12 ppm, and CO2 at 7.79%, confirming safe operation within acceptable parameters. Replaced the filtration components with one 213 media filter and one #35 water panel, and verified proper system operation upon completion.
Akron, OH 44333
Akron, OH - Relocated the condenser lineset and associated electrical to the new unit position on the exterior wall. Rerouted the insulated refrigerant lines and flexible whip from the outdoor disconnect to the condenser, secured them to the siding, and verified all connections are properly supported and weather-protected.
Ryan L.
Ryan L. Checked in
Relocated the condenser lineset and associated electrical to the new unit position on the exterior wall. Rerouted the insulated refrigerant lines and flexible whip from the outdoor disconnect to the condenser, secured them to the siding, and verified all connections are properly supported and weather-protected.
Akron, OH 44319
Akron, OH - Performed routine annual maintenance and tune-up on the gas furnace, which was operating properly upon arrival. Completed a combustion analysis using a flue gas analyzer, recording O2 at 8.82%, CO at 19 ppm, and CO2 at 6.79% on natural gas, with CO levels within acceptable limits. The system was left operating normally with no repairs required.
Jake T.
Jake T. Checked in
Performed routine annual maintenance and tune-up on the gas furnace, which was operating properly upon arrival. Completed a combustion analysis using a flue gas analyzer, recording O2 at 8.82%, CO at 19 ppm, and CO2 at 6.79% on natural gas, with CO levels within acceptable limits. The system was left operating normally with no repairs required.
Akron, OH 44313
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Roderick H.
Roderick H. Checked in
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Akron, OH 44310
Akron, OH - Performed annual preventive maintenance on a 16-year-old natural gas furnace, including a combustion analysis with a calibrated Bacharach analyzer. Final readings were within acceptable parameters: CO at 15 ppm, Oâ‚‚ at 9.4%, COâ‚‚ at 6.5%, and steady-state efficiency of 97.3%, confirming safe and proper combustion.
Maddex H.
Maddex H. Checked in
Performed annual preventive maintenance on a 16-year-old natural gas furnace, including a combustion analysis with a calibrated Bacharach analyzer. Final readings were within acceptable parameters: CO at 15 ppm, Oâ‚‚ at 9.4%, COâ‚‚ at 6.5%, and steady-state efficiency of 97.3%, confirming safe and proper combustion.
Akron, OH 44313
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Denver H.
Denver H. Checked in
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Akron, OH 44310
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Jim C.
Jim C. Checked in
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Akron, OH 44307

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.