Akron 44320 has the kind of housing where the age of the furnace does not always tell you the age of the system around it. Around Highland Square, Edgewood, Maple Valley, and other parts of West Akron, established colonials and mid-century homes can have decades of heating, cooling, plumbing, and remodeling work layered together. You may find a newer furnace connected to legacy ductwork, an older radiator system still doing its job, or forced-air equipment added during a previous renovation.
Lakes Heating & Air Conditioning works throughout Akron, OH 44320 helping homeowners sort through those combinations. Whether the problem is an aging gas furnace, dry winter air, plumbing that has been updated in stages, or an AC system struggling to move air through an older layout, we look at how the whole house is working before recommending the next step. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.
Older West Akron Homes Give Us More To Look At
The established housing stock is one of the things that makes 44320 different. Historic homes, older colonials, and mid-century properties are common, and many have conventional basements where several generations of mechanical work can be visible in the same room.
Legacy ductwork and radiator systems are still part of the picture in this area. Some homes have been converted to forced air, while others received newer heating or cooling equipment without completely changing the original distribution system. Enclosed rooms and older architectural layouts can also affect how air moves from one part of the house to another.
That is why we do not treat a comfort problem in Highland Square exactly like one in a newer home somewhere else. The layout, previous upgrades, and original construction can all point us toward the real cause.
Plumbing Repairs Often Start With Understanding What Changed
In an established Edgewood or Maple Valley home, the plumbing you can see may be much newer than what is behind the walls. Kitchens, bathrooms, water heaters, fixtures, and supply lines are often updated at different times, which can leave a mix of old and new components working together.
Conventional basements give us a useful place to start. Water heaters, gas lines, drains, and other utility connections often come together downstairs, making it easier to see where previous work was completed and where older sections remain.
Our plumbing services include:
- Plumbing installation
- Plumbing repair
- Water heaters
- Drain cleaning
- Bathroom remodel plumbing
- Faucet installation and repair
- Leak detection and repair
- Gas line installation
- Garbage disposals
- Toilets
- Sinks
- Sump pumps
A recurring slow drain, a change in water pressure, or hot water that does not last as long as it used to may be the first sign of a larger issue. We trace the problem before replacing parts that may not be causing it.
Indoor Air Quality Matters In Older, Enclosed Spaces
Older West Akron homes often have enclosed rooms and layouts that behave differently from newer open-concept construction. Add replacement windows, insulation improvements, and HVAC upgrades over time, and the way the house handles moisture and fresh air can change considerably.
The local climate adds another challenge. Warm, humid summers can leave lower levels or closed rooms feeling damp, while steady furnace operation through winter can make indoor air dry. Those opposite conditions are why humidity control is often part of the comfort conversation in 44320.
We install and service:
- Air cleaners
- Air scrubbers
- Air purifiers
- Humidifiers
- Dehumidifiers
- Thermostats
- Carbon monoxide detection
- Air ducts and ductwork
Air cleaners and scrubbers can help with filtration, while whole-home humidifiers and dehumidifiers address seasonal moisture throughout the house. When one area still feels different from another, we also check the ductwork because poor circulation can affect both air quality and temperature.
Heating Service For West Akron's Long Winter Runs
Northeast Ohio winters bring cold temperatures, snow, and lake-effect influence that can keep heating equipment running for long stretches. That is when weaknesses in older furnaces, legacy duct systems, or converted heating layouts become easier to notice.
Around 44320, we may be working on a traditional gas furnace in one house and a radiator or updated forced-air system in another. Older colonials can also have rooms that respond differently because of the original floor plan, especially when a heating system has been changed without completely redesigning how heat is distributed.
Our heating services include:
- Emergency heating
- Heating repair
- Heating installation
- Heating maintenance
- Furnaces
- Boilers
- Heat pumps
- Geothermal services
- Space heating
- Snowmelt systems
- HVAC services
- New construction HVAC
- Commercial heating
When part of a Highland Square home stays colder than the rest, we look at the furnace along with the ductwork, controls, airflow, and distribution. In a house with legacy equipment, the issue may be tied to the way the system has evolved over decades rather than one failed component.
AC Service For Humid Akron Summers
Warm, humid summers can put older cooling layouts to the test, especially in homes where central air was added after the original construction. Around Highland Square and the western Akron corridors, the cooling system may be working through ductwork that was designed around a different generation of equipment.
That can show up as warmer upstairs rooms, longer run times, or certain areas that never receive the same airflow. In older colonials and mid-century homes, enclosed rooms and previous renovations can also make one side of the house respond differently than another.
Lakes provides:
- Emergency AC services
- AC repair
- AC installation
- AC maintenance
- Ductless air conditioning
- Packaged units
- HVAC services
- New construction HVAC
- Commercial AC
We check equipment performance alongside return airflow, duct condition, and the way conditioned air moves through the floor plan. High-efficiency cooling equipment can be a good upgrade, but it still needs the rest of the system to support it.
Service For The Layered Systems Found In Akron 44320
Highland Square, Edgewood, Maple Valley, and the surrounding West Akron neighborhoods include homes that have been maintained and changed over several generations. Legacy ductwork may serve newer equipment. Radiator systems may still be active in one property while a forced-air conversion sits a few doors away. Plumbing and indoor air upgrades can add another layer to that mechanical history.
Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44320. Call (330) 536-1276 or contact us online today to schedule service.
Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026.
The most recent job was on November 17, 2026.
Lakes Heating, Air Conditioning & Plumbing INC has completed 937 jobs in Akron, OH in the last 12 months.
Job Locations and Reviews
Responded to a no-heat call on a Lennox gas furnace over 10 years old, removing the front access panel to inspect the burner assembly, wiring, and control components. Diagnosed and resolved the cause of heat failure, then verified safe ignition, proper flame characteristics, and normal heating cycle operation. Confirmed PVC venting connections and the surrounding plenum and humidifier assembly were intact, and returned the system to full operation.
Responded to a 15-year-old gas furnace short cycling and failing to reach thermostat setpoint. Removed the front access panel and inspected the draft inducer assembly, gas valve, control board, wiring, and transformer, and found the filter dirty and out of position with dust buildup throughout the cabinet. Removed the clogged filter and cleaned the cabinet and components, which are common causes of overheating and limit-switch cycling, and recommended a properly seated replacement filter to restore airflow and normal heating cycles.
Performed seasonal heating maintenance on a 15-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: 19 ppm CO, 7.1% Oâ‚‚, 7.8% COâ‚‚, 106°F stack temperature, and 95.0% combustion efficiency. Unit operating properly at completion of service.
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis with a Bacharach analyzer. Results confirmed safe, efficient operation with flue gas readings of 9.6% Oâ‚‚, 18 ppm CO, 6.4% COâ‚‚, 99°F stack temperature, and 95.7% combustion efficiency, all within acceptable parameters.
Evaluated existing gas-fired furnace installation for replacement, inspecting the burner assembly, gas valve, inducer/blower motor, electrical connections, and associated plenum and ductwork. Noted condensation on the galvanized flue vent, indicating a venting deficiency to be addressed during the retrofit. Recommended furnace replacement with proper vent sizing and material, along with gas piping and electrical connections brought to current code.
Performed annual heating maintenance on a gas furnace, including a combustion analysis with a calibrated flue gas analyzer. Readings were within normal operating range for natural gas: O2 at 11.0%, CO at 11 ppm, and CO2 at 5.57%. The unit was found operating properly at completion.
Performed seasonal heating system maintenance on the boiler, including a combustion efficiency analysis using a Testo 310 flue gas analyzer. Readings showed Oâ‚‚ at 8.4% and CO at 4 ppm, indicating safe carbon monoxide levels and stable combustion, and the circulator pump and associated piping were inspected as part of the tune-up.
Diagnosed a no-heat condition on the master bath radiant floor heating system and traced the fault to the line-voltage supply, where the power cord plug showed heavy burning, charring, and melted insulation at the prongs, with scorching and staining also present at the wall receptacle. Verified power and continuity with a multimeter, then isolated the damaged cord and receptacle as the cause of the loss of power to the heating element.
Performed seasonal heating maintenance on a 12-year-old natural gas furnace, including a combustion analysis with a Bacharach Fyrite InTech analyzer. Readings were within normal operating range at 7.9% O2, 7.3% CO2, 15 ppm CO, and 95.9% efficiency, confirming clean, efficient combustion. Updated the maintenance service history record on the unit.
Performed tune-up service on two gas furnaces (both over 10 years old), including combustion analysis of each unit under natural gas operation. Results were within acceptable ranges: O2 7.7%, CO 8 ppm, CO2 7.5%, and 82.3% efficiency on the first furnace, and O2 8.4%, CO 6 ppm, CO2 7.0%, and 81.9% efficiency on the second. Both systems are operating safely and efficiently, and the service history labels were applied to the equipment.
Responded to a gas furnace short-cycling complaint and inspected the air handler cabinet, finding heavy dust and lint buildup on the blower assembly, motor housing, support arms, and wiring, along with debris on the cabinet floor and a loose screw. The restricted airflow and dirty blower likely caused the unit to overheat and trip the limit switch, resulting in the intermittent cycling. Used a borescope to inspect hard-to-reach internal areas, and recommended cleaning the blower assembly and replacing the air filter to restore proper airflow and prevent recurrence.
Responded to a no-heat call on a 20-year-old furnace that was heating intermittently. Performed a combustion analysis with a Testo 310 analyzer, which recorded 6.1% O2 and 18 ppm CO in the flue gases, to evaluate burner operation and combustion efficiency. Diagnosed the intermittent heating condition using these readings along with an inspection of the unit's operation.
Diagnosed a 10-year-old gas furnace short-cycling on a flame-sensing fault, then verified combustion performance with a Testo 310 analyzer. Readings showed Oâ‚‚ at 7.8% and CO at 18 ppm, within acceptable limits, and the furnace now holds a stable flame and completes normal heating cycles.
Performed scheduled preventive maintenance on a 9-year-old residential natural gas furnace. Conducted a combustion analysis on the unit, recording O2 at 8.6%, CO at 41 ppm, CO2 at 7.0%, and steady-state efficiency of 94.5%, with all readings within acceptable operating parameters. Verified the Aprilaire reminder label on the ductwork for filter/media replacement tracking.
Performed seasonal contract maintenance on a York gas/electric rooftop unit, including inspection of the burner and heat exchanger compartment, blower and motor assembly, and electrical components, with the access panels opened for service. Verified the condensate drain and disconnect, replaced the filter set with (4) 16x24x2 filters, and noted rust staining on the curb and roof surface wear for monitoring.
Performed seasonal heating maintenance on a 3-year-old gas furnace, including a combustion analysis to verify safe and efficient operation. Readings on natural gas were within normal range at O2 6.6%, CO 19 ppm, CO2 8.1%, and 98.4% efficiency. The system is operating properly, and the customer's maintenance plan is due for renewal.
Performed seasonal heating maintenance on two gas furnaces (approximately 25 and 10 years old), including combustion analysis and electrical testing. Combustion readings on natural gas were within normal range at 10.5% Oâ‚‚, 15 ppm CO, 5.9% COâ‚‚, and 89°F stack temperature, and electrical measurements were verified with a clamp meter. Both systems were left operational.
Responded to water leak beneath a 22-year-old gas furnace and traced the source to the condensate trap/cleanout housing, which showed heavy corrosion, mineral buildup, and active seepage at the PVC drain connection, with staining visible on the cabinet base and slab. Inspected the condensate hoses and surrounding blower compartment, which showed rust and mineral deposits consistent with long-term condensate leakage. Documented findings and recommended replacement of the deteriorated condensate trap and related drain components to prevent further water damage and corrosion.
Performed annual heating maintenance on two natural gas furnaces (approximately 11 and 15 years old), including a combustion analysis on each unit that showed CO at 11 ppm and 14 ppm, within safe operating limits, with efficiency readings of 95.7% and 98.0%. Both units operated normally with no visible damage or unusual conditions noted, and the maintenance plan was renewed with a follow-up reminder set.
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.