Heating, AC & Plumbing Services in Akron, OH 44320

Akron 44320 has the kind of housing where the age of the furnace does not always tell you the age of the system around it. Around Highland Square, Edgewood, Maple Valley, and other parts of West Akron, established colonials and mid-century homes can have decades of heating, cooling, plumbing, and remodeling work layered together. You may find a newer furnace connected to legacy ductwork, an older radiator system still doing its job, or forced-air equipment added during a previous renovation.

Lakes Heating & Air Conditioning works throughout Akron, OH 44320 helping homeowners sort through those combinations. Whether the problem is an aging gas furnace, dry winter air, plumbing that has been updated in stages, or an AC system struggling to move air through an older layout, we look at how the whole house is working before recommending the next step. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.

Older West Akron Homes Give Us More To Look At

The established housing stock is one of the things that makes 44320 different. Historic homes, older colonials, and mid-century properties are common, and many have conventional basements where several generations of mechanical work can be visible in the same room.

Legacy ductwork and radiator systems are still part of the picture in this area. Some homes have been converted to forced air, while others received newer heating or cooling equipment without completely changing the original distribution system. Enclosed rooms and older architectural layouts can also affect how air moves from one part of the house to another.

That is why we do not treat a comfort problem in Highland Square exactly like one in a newer home somewhere else. The layout, previous upgrades, and original construction can all point us toward the real cause.

Plumbing Repairs Often Start With Understanding What Changed

In an established Edgewood or Maple Valley home, the plumbing you can see may be much newer than what is behind the walls. Kitchens, bathrooms, water heaters, fixtures, and supply lines are often updated at different times, which can leave a mix of old and new components working together.

Conventional basements give us a useful place to start. Water heaters, gas lines, drains, and other utility connections often come together downstairs, making it easier to see where previous work was completed and where older sections remain.

Our plumbing services include:

  • Plumbing installation
  • Plumbing repair
  • Water heaters
  • Drain cleaning
  • Bathroom remodel plumbing
  • Faucet installation and repair
  • Leak detection and repair
  • Gas line installation
  • Garbage disposals
  • Toilets
  • Sinks
  • Sump pumps

A recurring slow drain, a change in water pressure, or hot water that does not last as long as it used to may be the first sign of a larger issue. We trace the problem before replacing parts that may not be causing it.

Indoor Air Quality Matters In Older, Enclosed Spaces

Older West Akron homes often have enclosed rooms and layouts that behave differently from newer open-concept construction. Add replacement windows, insulation improvements, and HVAC upgrades over time, and the way the house handles moisture and fresh air can change considerably.

The local climate adds another challenge. Warm, humid summers can leave lower levels or closed rooms feeling damp, while steady furnace operation through winter can make indoor air dry. Those opposite conditions are why humidity control is often part of the comfort conversation in 44320.

We install and service:

  • Air cleaners
  • Air scrubbers
  • Air purifiers
  • Humidifiers
  • Dehumidifiers
  • Thermostats
  • Carbon monoxide detection
  • Air ducts and ductwork

Air cleaners and scrubbers can help with filtration, while whole-home humidifiers and dehumidifiers address seasonal moisture throughout the house. When one area still feels different from another, we also check the ductwork because poor circulation can affect both air quality and temperature.

Heating Service For West Akron's Long Winter Runs

Northeast Ohio winters bring cold temperatures, snow, and lake-effect influence that can keep heating equipment running for long stretches. That is when weaknesses in older furnaces, legacy duct systems, or converted heating layouts become easier to notice.

Around 44320, we may be working on a traditional gas furnace in one house and a radiator or updated forced-air system in another. Older colonials can also have rooms that respond differently because of the original floor plan, especially when a heating system has been changed without completely redesigning how heat is distributed.

Our heating services include:

When part of a Highland Square home stays colder than the rest, we look at the furnace along with the ductwork, controls, airflow, and distribution. In a house with legacy equipment, the issue may be tied to the way the system has evolved over decades rather than one failed component.

AC Service For Humid Akron Summers

Warm, humid summers can put older cooling layouts to the test, especially in homes where central air was added after the original construction. Around Highland Square and the western Akron corridors, the cooling system may be working through ductwork that was designed around a different generation of equipment.

That can show up as warmer upstairs rooms, longer run times, or certain areas that never receive the same airflow. In older colonials and mid-century homes, enclosed rooms and previous renovations can also make one side of the house respond differently than another.

Lakes provides:

We check equipment performance alongside return airflow, duct condition, and the way conditioned air moves through the floor plan. High-efficiency cooling equipment can be a good upgrade, but it still needs the rest of the system to support it.

Service For The Layered Systems Found In Akron 44320

Highland Square, Edgewood, Maple Valley, and the surrounding West Akron neighborhoods include homes that have been maintained and changed over several generations. Legacy ductwork may serve newer equipment. Radiator systems may still be active in one property while a forced-air conversion sits a few doors away. Plumbing and indoor air upgrades can add another layer to that mechanical history.

Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44320. Call (330) 536-1276 or contact us online today to schedule service.

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026.

The most recent job was on November 17, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 937 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Akron, OH - Responded to a no-heat call on a Lennox gas furnace over 10 years old, removing the front access panel to inspect the burner assembly, wiring, and control components. Diagnosed and resolved the cause of heat failure, then verified safe ignition, proper flame characteristics, and normal heating cycle operation. Confirmed PVC venting connections and the surrounding plenum and humidifier assembly were intact, and returned the system to full operation.
Zack W.
Zack W. Checked in
Responded to a no-heat call on a Lennox gas furnace over 10 years old, removing the front access panel to inspect the burner assembly, wiring, and control components. Diagnosed and resolved the cause of heat failure, then verified safe ignition, proper flame characteristics, and normal heating cycle operation. Confirmed PVC venting connections and the surrounding plenum and humidifier assembly were intact, and returned the system to full operation.
Akron, OH 44319
Akron, OH - Responded to a 15-year-old gas furnace short cycling and failing to reach thermostat setpoint. Removed the front access panel and inspected the draft inducer assembly, gas valve, control board, wiring, and transformer, and found the filter dirty and out of position with dust buildup throughout the cabinet. Removed the clogged filter and cleaned the cabinet and components, which are common causes of overheating and limit-switch cycling, and recommended a properly seated replacement filter to restore airflow and normal heating cycles.
Zack W.
Zack W. Checked in
Responded to a 15-year-old gas furnace short cycling and failing to reach thermostat setpoint. Removed the front access panel and inspected the draft inducer assembly, gas valve, control board, wiring, and transformer, and found the filter dirty and out of position with dust buildup throughout the cabinet. Removed the clogged filter and cleaned the cabinet and components, which are common causes of overheating and limit-switch cycling, and recommended a properly seated replacement filter to restore airflow and normal heating cycles.
Akron, OH 44319
Akron, OH - Performed seasonal heating maintenance on a 15-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: 19 ppm CO, 7.1% Oâ‚‚, 7.8% COâ‚‚, 106°F stack temperature, and 95.0% combustion efficiency. Unit operating properly at completion of service.
Maddex H.
Maddex H. Checked in
Performed seasonal heating maintenance on a 15-year-old natural gas furnace, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: 19 ppm CO, 7.1% Oâ‚‚, 7.8% COâ‚‚, 106°F stack temperature, and 95.0% combustion efficiency. Unit operating properly at completion of service.
Akron, OH 44313
Akron, OH - Performed fall heating maintenance on a natural gas furnace, including a combustion analysis with a Bacharach analyzer. Results confirmed safe, efficient operation with flue gas readings of 9.6% Oâ‚‚, 18 ppm CO, 6.4% COâ‚‚, 99°F stack temperature, and 95.7% combustion efficiency, all within acceptable parameters.
Maddex H.
Maddex H. Checked in
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis with a Bacharach analyzer. Results confirmed safe, efficient operation with flue gas readings of 9.6% Oâ‚‚, 18 ppm CO, 6.4% COâ‚‚, 99°F stack temperature, and 95.7% combustion efficiency, all within acceptable parameters.
Akron, OH 44319
Evaluated existing gas-fired furnace installation for replacement, inspecting the burner assembly, gas valve, inducer/blower motor, electrical connections, and associated plenum and ductwork. Noted condensation on the galvanized flue vent, indicating a venting deficiency to be addressed during the retrofit. Recommended furnace replacement with proper vent sizing and material, along with gas piping and electrical connections brought to current code.
Evaluated existing gas-fired furnace installation for replacement, inspecting the burner assembly, gas valve, inducer/blower motor, electrical connections, and associated plenum and ductwork. Noted condensation on the galvanized flue vent, indicating a venting deficiency to be addressed during the retrofit. Recommended furnace replacement with proper vent sizing and material, along with gas piping and electrical connections brought to current code.
Justin B.
Justin B. Checked in
Evaluated existing gas-fired furnace installation for replacement, inspecting the burner assembly, gas valve, inducer/blower motor, electrical connections, and associated plenum and ductwork. Noted condensation on the galvanized flue vent, indicating a venting deficiency to be addressed during the retrofit. Recommended furnace replacement with proper vent sizing and material, along with gas piping and electrical connections brought to current code.
Akron, OH 44320
Akron, OH - Performed annual heating maintenance on a gas furnace, including a combustion analysis with a calibrated flue gas analyzer. Readings were within normal operating range for natural gas: O2 at 11.0%, CO at 11 ppm, and CO2 at 5.57%. The unit was found operating properly at completion.
Jake T.
Jake T. Checked in
Performed annual heating maintenance on a gas furnace, including a combustion analysis with a calibrated flue gas analyzer. Readings were within normal operating range for natural gas: O2 at 11.0%, CO at 11 ppm, and CO2 at 5.57%. The unit was found operating properly at completion.
Akron, OH 44312
Performed seasonal heating system maintenance on the boiler, including a combustion efficiency analysis using a Testo 310 flue gas analyzer. Readings showed Oâ‚‚ at 8.4% and CO at 4 ppm, indicating safe carbon monoxide levels and stable combustion, and the circulator pump and associated piping were inspected as part of the tune-up.
Performed seasonal heating system maintenance on the boiler, including a combustion efficiency analysis using a Testo 310 flue gas analyzer. Readings showed Oâ‚‚ at 8.4% and CO at 4 ppm, indicating safe carbon monoxide levels and stable combustion, and the circulator pump and associated piping were inspected as part of the tune-up.
Nick D.
Nick D. Checked in
Performed seasonal heating system maintenance on the boiler, including a combustion efficiency analysis using a Testo 310 flue gas analyzer. Readings showed Oâ‚‚ at 8.4% and CO at 4 ppm, indicating safe carbon monoxide levels and stable combustion, and the circulator pump and associated piping were inspected as part of the tune-up.
Akron, OH 44319
Diagnosed a no-heat condition on the master bath radiant floor heating system and traced the fault to the line-voltage supply, where the power cord plug showed heavy burning, charring, and melted insulation at the prongs, with scorching and staining also present at the wall receptacle. Verified power and continuity with a multimeter, then isolated the damaged cord and receptacle as the cause of the loss of power to the heating element.
Diagnosed a no-heat condition on the master bath radiant floor heating system and traced the fault to the line-voltage supply, where the power cord plug showed heavy burning, charring, and melted insulation at the prongs, with scorching and staining also present at the wall receptacle. Verified power and continuity with a multimeter, then isolated the damaged cord and receptacle as the cause of the loss of power to the heating element.
Zack W.
Zack W. Checked in
Diagnosed a no-heat condition on the master bath radiant floor heating system and traced the fault to the line-voltage supply, where the power cord plug showed heavy burning, charring, and melted insulation at the prongs, with scorching and staining also present at the wall receptacle. Verified power and continuity with a multimeter, then isolated the damaged cord and receptacle as the cause of the loss of power to the heating element.
Akron, OH 44313
Akron, OH - Performed seasonal heating maintenance on a 12-year-old natural gas furnace, including a combustion analysis with a Bacharach Fyrite InTech analyzer. Readings were within normal operating range at 7.9% O2, 7.3% CO2, 15 ppm CO, and 95.9% efficiency, confirming clean, efficient combustion. Updated the maintenance service history record on the unit.
Brynn L.
Brynn L. Checked in
Performed seasonal heating maintenance on a 12-year-old natural gas furnace, including a combustion analysis with a Bacharach Fyrite InTech analyzer. Readings were within normal operating range at 7.9% O2, 7.3% CO2, 15 ppm CO, and 95.9% efficiency, confirming clean, efficient combustion. Updated the maintenance service history record on the unit.
Akron, OH 44312
Performed tune-up service on two gas furnaces (both over 10 years old), including combustion analysis of each unit under natural gas operation. Results were within acceptable ranges: O2 7.7%, CO 8 ppm, CO2 7.5%, and 82.3% efficiency on the first furnace, and O2 8.4%, CO 6 ppm, CO2 7.0%, and 81.9% efficiency on the second. Both systems are operating safely and efficiently, and the service history labels were applied to the equipment.
Performed tune-up service on two gas furnaces (both over 10 years old), including combustion analysis of each unit under natural gas operation. Results were within acceptable ranges: O2 7.7%, CO 8 ppm, CO2 7.5%, and 82.3% efficiency on the first furnace, and O2 8.4%, CO 6 ppm, CO2 7.0%, and 81.9% efficiency on the second. Both systems are operating safely and efficiently, and the service history labels were applied to the equipment.
Brynn L.
Brynn L. Checked in
Performed tune-up service on two gas furnaces (both over 10 years old), including combustion analysis of each unit under natural gas operation. Results were within acceptable ranges: O2 7.7%, CO 8 ppm, CO2 7.5%, and 82.3% efficiency on the first furnace, and O2 8.4%, CO 6 ppm, CO2 7.0%, and 81.9% efficiency on the second. Both systems are operating safely and efficiently, and the service history labels were applied to the equipment.
Akron, OH 44321
Responded to a gas furnace short-cycling complaint and inspected the air handler cabinet, finding heavy dust and lint buildup on the blower assembly, motor housing, support arms, and wiring, along with debris on the cabinet floor and a loose screw. The restricted airflow and dirty blower likely caused the unit to overheat and trip the limit switch, resulting in the intermittent cycling. Used a borescope to inspect hard-to-reach internal areas, and recommended cleaning the blower assembly and replacing the air filter to restore proper airflow and prevent recurrence.
Responded to a gas furnace short-cycling complaint and inspected the air handler cabinet, finding heavy dust and lint buildup on the blower assembly, motor housing, support arms, and wiring, along with debris on the cabinet floor and a loose screw. The restricted airflow and dirty blower likely caused the unit to overheat and trip the limit switch, resulting in the intermittent cycling. Used a borescope to inspect hard-to-reach internal areas, and recommended cleaning the blower assembly and replacing the air filter to restore proper airflow and prevent recurrence.
Nick D.
Nick D. Checked in
Responded to a gas furnace short-cycling complaint and inspected the air handler cabinet, finding heavy dust and lint buildup on the blower assembly, motor housing, support arms, and wiring, along with debris on the cabinet floor and a loose screw. The restricted airflow and dirty blower likely caused the unit to overheat and trip the limit switch, resulting in the intermittent cycling. Used a borescope to inspect hard-to-reach internal areas, and recommended cleaning the blower assembly and replacing the air filter to restore proper airflow and prevent recurrence.
Akron, OH 44320
Akron, OH - Responded to a no-heat call on a 20-year-old furnace that was heating intermittently. Performed a combustion analysis with a Testo 310 analyzer, which recorded 6.1% O2 and 18 ppm CO in the flue gases, to evaluate burner operation and combustion efficiency. Diagnosed the intermittent heating condition using these readings along with an inspection of the unit's operation.
Nick D.
Nick D. Checked in
Responded to a no-heat call on a 20-year-old furnace that was heating intermittently. Performed a combustion analysis with a Testo 310 analyzer, which recorded 6.1% O2 and 18 ppm CO in the flue gases, to evaluate burner operation and combustion efficiency. Diagnosed the intermittent heating condition using these readings along with an inspection of the unit's operation.
Akron, OH 44319
Akron, OH - Diagnosed a 10-year-old gas furnace short-cycling on a flame-sensing fault, then verified combustion performance with a Testo 310 analyzer. Readings showed Oâ‚‚ at 7.8% and CO at 18 ppm, within acceptable limits, and the furnace now holds a stable flame and completes normal heating cycles.
Nick D.
Nick D. Checked in
Diagnosed a 10-year-old gas furnace short-cycling on a flame-sensing fault, then verified combustion performance with a Testo 310 analyzer. Readings showed Oâ‚‚ at 7.8% and CO at 18 ppm, within acceptable limits, and the furnace now holds a stable flame and completes normal heating cycles.
Akron, OH 44319
Akron, OH - Performed scheduled preventive maintenance on a 9-year-old residential natural gas furnace. Conducted a combustion analysis on the unit, recording O2 at 8.6%, CO at 41 ppm, CO2 at 7.0%, and steady-state efficiency of 94.5%, with all readings within acceptable operating parameters. Verified the Aprilaire reminder label on the ductwork for filter/media replacement tracking.
Brynn L.
Brynn L. Checked in
Performed scheduled preventive maintenance on a 9-year-old residential natural gas furnace. Conducted a combustion analysis on the unit, recording O2 at 8.6%, CO at 41 ppm, CO2 at 7.0%, and steady-state efficiency of 94.5%, with all readings within acceptable operating parameters. Verified the Aprilaire reminder label on the ductwork for filter/media replacement tracking.
Akron, OH 44313
Performed seasonal contract maintenance on a York gas/electric rooftop unit, including inspection of the burner and heat exchanger compartment, blower and motor assembly, and electrical components, with the access panels opened for service. Verified the condensate drain and disconnect, replaced the filter set with (4) 16x24x2 filters, and noted rust staining on the curb and roof surface wear for monitoring.
Performed seasonal contract maintenance on a York gas/electric rooftop unit, including inspection of the burner and heat exchanger compartment, blower and motor assembly, and electrical components, with the access panels opened for service. Verified the condensate drain and disconnect, replaced the filter set with (4) 16x24x2 filters, and noted rust staining on the curb and roof surface wear for monitoring.
Roderick H.
Roderick H. Checked in
Performed seasonal contract maintenance on a York gas/electric rooftop unit, including inspection of the burner and heat exchanger compartment, blower and motor assembly, and electrical components, with the access panels opened for service. Verified the condensate drain and disconnect, replaced the filter set with (4) 16x24x2 filters, and noted rust staining on the curb and roof surface wear for monitoring.
Akron, OH 44319
Akron, OH - Performed seasonal heating maintenance on a 3-year-old gas furnace, including a combustion analysis to verify safe and efficient operation. Readings on natural gas were within normal range at O2 6.6%, CO 19 ppm, CO2 8.1%, and 98.4% efficiency. The system is operating properly, and the customer's maintenance plan is due for renewal.
Brynn L.
Brynn L. Checked in
Performed seasonal heating maintenance on a 3-year-old gas furnace, including a combustion analysis to verify safe and efficient operation. Readings on natural gas were within normal range at O2 6.6%, CO 19 ppm, CO2 8.1%, and 98.4% efficiency. The system is operating properly, and the customer's maintenance plan is due for renewal.
Akron, OH 44321
Performed seasonal heating maintenance on two gas furnaces (approximately 25 and 10 years old), including combustion analysis and electrical testing. Combustion readings on natural gas were within normal range at 10.5% Oâ‚‚, 15 ppm CO, 5.9% COâ‚‚, and 89°F stack temperature, and electrical measurements were verified with a clamp meter. Both systems were left operational.
Performed seasonal heating maintenance on two gas furnaces (approximately 25 and 10 years old), including combustion analysis and electrical testing. Combustion readings on natural gas were within normal range at 10.5% Oâ‚‚, 15 ppm CO, 5.9% COâ‚‚, and 89°F stack temperature, and electrical measurements were verified with a clamp meter. Both systems were left operational.
Maddex H.
Maddex H. Checked in
Performed seasonal heating maintenance on two gas furnaces (approximately 25 and 10 years old), including combustion analysis and electrical testing. Combustion readings on natural gas were within normal range at 10.5% Oâ‚‚, 15 ppm CO, 5.9% COâ‚‚, and 89°F stack temperature, and electrical measurements were verified with a clamp meter. Both systems were left operational.
Akron, OH 44333
Responded to water leak beneath a 22-year-old gas furnace and traced the source to the condensate trap/cleanout housing, which showed heavy corrosion, mineral buildup, and active seepage at the PVC drain connection, with staining visible on the cabinet base and slab. Inspected the condensate hoses and surrounding blower compartment, which showed rust and mineral deposits consistent with long-term condensate leakage. Documented findings and recommended replacement of the deteriorated condensate trap and related drain components to prevent further water damage and corrosion.
Responded to water leak beneath a 22-year-old gas furnace and traced the source to the condensate trap/cleanout housing, which showed heavy corrosion, mineral buildup, and active seepage at the PVC drain connection, with staining visible on the cabinet base and slab. Inspected the condensate hoses and surrounding blower compartment, which showed rust and mineral deposits consistent with long-term condensate leakage. Documented findings and recommended replacement of the deteriorated condensate trap and related drain components to prevent further water damage and corrosion.
Nick D.
Nick D. Checked in
Responded to water leak beneath a 22-year-old gas furnace and traced the source to the condensate trap/cleanout housing, which showed heavy corrosion, mineral buildup, and active seepage at the PVC drain connection, with staining visible on the cabinet base and slab. Inspected the condensate hoses and surrounding blower compartment, which showed rust and mineral deposits consistent with long-term condensate leakage. Documented findings and recommended replacement of the deteriorated condensate trap and related drain components to prevent further water damage and corrosion.
Akron, OH 44321
Performed annual heating maintenance on two natural gas furnaces (approximately 11 and 15 years old), including a combustion analysis on each unit that showed CO at 11 ppm and 14 ppm, within safe operating limits, with efficiency readings of 95.7% and 98.0%. Both units operated normally with no visible damage or unusual conditions noted, and the maintenance plan was renewed with a follow-up reminder set.
Performed annual heating maintenance on two natural gas furnaces (approximately 11 and 15 years old), including a combustion analysis on each unit that showed CO at 11 ppm and 14 ppm, within safe operating limits, with efficiency readings of 95.7% and 98.0%. Both units operated normally with no visible damage or unusual conditions noted, and the maintenance plan was renewed with a follow-up reminder set.
Brynn L.
Brynn L. Checked in
Performed annual heating maintenance on two natural gas furnaces (approximately 11 and 15 years old), including a combustion analysis on each unit that showed CO at 11 ppm and 14 ppm, within safe operating limits, with efficiency readings of 95.7% and 98.0%. Both units operated normally with no visible damage or unusual conditions noted, and the maintenance plan was renewed with a follow-up reminder set.
Akron, OH 44333
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Denver H.
Denver H. Checked in
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Akron, OH 44306

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.