Akron 44320 has the kind of housing where the age of the furnace does not always tell you the age of the system around it. Around Highland Square, Edgewood, Maple Valley, and other parts of West Akron, established colonials and mid-century homes can have decades of heating, cooling, plumbing, and remodeling work layered together. You may find a newer furnace connected to legacy ductwork, an older radiator system still doing its job, or forced-air equipment added during a previous renovation.
Lakes Heating & Air Conditioning works throughout Akron, OH 44320 helping homeowners sort through those combinations. Whether the problem is an aging gas furnace, dry winter air, plumbing that has been updated in stages, or an AC system struggling to move air through an older layout, we look at how the whole house is working before recommending the next step. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.
Older West Akron Homes Give Us More To Look At
The established housing stock is one of the things that makes 44320 different. Historic homes, older colonials, and mid-century properties are common, and many have conventional basements where several generations of mechanical work can be visible in the same room.
Legacy ductwork and radiator systems are still part of the picture in this area. Some homes have been converted to forced air, while others received newer heating or cooling equipment without completely changing the original distribution system. Enclosed rooms and older architectural layouts can also affect how air moves from one part of the house to another.
That is why we do not treat a comfort problem in Highland Square exactly like one in a newer home somewhere else. The layout, previous upgrades, and original construction can all point us toward the real cause.
Plumbing Repairs Often Start With Understanding What Changed
In an established Edgewood or Maple Valley home, the plumbing you can see may be much newer than what is behind the walls. Kitchens, bathrooms, water heaters, fixtures, and supply lines are often updated at different times, which can leave a mix of old and new components working together.
Conventional basements give us a useful place to start. Water heaters, gas lines, drains, and other utility connections often come together downstairs, making it easier to see where previous work was completed and where older sections remain.
Our plumbing services include:
- Plumbing installation
- Plumbing repair
- Water heaters
- Drain cleaning
- Bathroom remodel plumbing
- Faucet installation and repair
- Leak detection and repair
- Gas line installation
- Garbage disposals
- Toilets
- Sinks
- Sump pumps
A recurring slow drain, a change in water pressure, or hot water that does not last as long as it used to may be the first sign of a larger issue. We trace the problem before replacing parts that may not be causing it.
Indoor Air Quality Matters In Older, Enclosed Spaces
Older West Akron homes often have enclosed rooms and layouts that behave differently from newer open-concept construction. Add replacement windows, insulation improvements, and HVAC upgrades over time, and the way the house handles moisture and fresh air can change considerably.
The local climate adds another challenge. Warm, humid summers can leave lower levels or closed rooms feeling damp, while steady furnace operation through winter can make indoor air dry. Those opposite conditions are why humidity control is often part of the comfort conversation in 44320.
We install and service:
- Air cleaners
- Air scrubbers
- Air purifiers
- Humidifiers
- Dehumidifiers
- Thermostats
- Carbon monoxide detection
- Air ducts and ductwork
Air cleaners and scrubbers can help with filtration, while whole-home humidifiers and dehumidifiers address seasonal moisture throughout the house. When one area still feels different from another, we also check the ductwork because poor circulation can affect both air quality and temperature.
Heating Service For West Akron's Long Winter Runs
Northeast Ohio winters bring cold temperatures, snow, and lake-effect influence that can keep heating equipment running for long stretches. That is when weaknesses in older furnaces, legacy duct systems, or converted heating layouts become easier to notice.
Around 44320, we may be working on a traditional gas furnace in one house and a radiator or updated forced-air system in another. Older colonials can also have rooms that respond differently because of the original floor plan, especially when a heating system has been changed without completely redesigning how heat is distributed.
Our heating services include:
- Emergency heating
- Heating repair
- Heating installation
- Heating maintenance
- Furnaces
- Boilers
- Heat pumps
- Geothermal services
- Space heating
- Snowmelt systems
- HVAC services
- New construction HVAC
- Commercial heating
When part of a Highland Square home stays colder than the rest, we look at the furnace along with the ductwork, controls, airflow, and distribution. In a house with legacy equipment, the issue may be tied to the way the system has evolved over decades rather than one failed component.
AC Service For Humid Akron Summers
Warm, humid summers can put older cooling layouts to the test, especially in homes where central air was added after the original construction. Around Highland Square and the western Akron corridors, the cooling system may be working through ductwork that was designed around a different generation of equipment.
That can show up as warmer upstairs rooms, longer run times, or certain areas that never receive the same airflow. In older colonials and mid-century homes, enclosed rooms and previous renovations can also make one side of the house respond differently than another.
Lakes provides:
- Emergency AC services
- AC repair
- AC installation
- AC maintenance
- Ductless air conditioning
- Packaged units
- HVAC services
- New construction HVAC
- Commercial AC
We check equipment performance alongside return airflow, duct condition, and the way conditioned air moves through the floor plan. High-efficiency cooling equipment can be a good upgrade, but it still needs the rest of the system to support it.
Service For The Layered Systems Found In Akron 44320
Highland Square, Edgewood, Maple Valley, and the surrounding West Akron neighborhoods include homes that have been maintained and changed over several generations. Legacy ductwork may serve newer equipment. Radiator systems may still be active in one property while a forced-air conversion sits a few doors away. Plumbing and indoor air upgrades can add another layer to that mechanical history.
Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44320. Call (330) 536-1276 or contact us online today to schedule service.
Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH between February 2026 and March 2026.
The most recent job was on March 3, 2026.
Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.
Job Locations and Reviews
Responded to service callback for insufficient heating complaint. Upon inspection of the furnace, performed diagnostic testing on the blower motor assembly and circuit board, revealing a loose electrical connection in the wire harness. Repaired faulty connection and verified proper system operation with normal heating output restored.
Responded to service call for water leak potentially originating from humidifier. Upon inspection of the HVAC system installation and surrounding plumbing, identified and documented PVC pipe drainage configuration passing through the diamond plate flooring. Performed thorough assessment of the mechanical equipment and connections to ensure proper functionality.
Responded to service call for 20-year-old furnace with intermittent operation and ignition failure. Inspection revealed worn ignitor assembly with deteriorated wiring connections at the flame sensor and gas valve. Replaced ignitor assembly, cleaned flame sensor, and restored proper connection terminals to resolve cycling issues.
Responded to no heat complaint - diagnosed faulty thermostat (2 years old) affecting system operation. Performed measurements of supply and return air registers (5-6" dimensions noted) and observed significant rust/corrosion in return air housing that could impact airflow. Replaced thermostat and restored heating functionality to Modulating Variable Performance system (2025 MVP).
Performed site evaluation of existing HVAC system to address customer's concern about furnace sizing. Inspected current installation including furnace unit with connected ductwork, adjacent water heater system, and associated plumbing components. Documented existing equipment configuration to prepare appropriate replacement options considering natural gas efficiency and proper system sizing.
Performed comprehensive inspection on 10-year-old Weil-McLain LGB Series 2 boiler system. Visual examination revealed properly installed components including copper/black piping network, pressure gauges, and pump assembly all in working condition. Documented system specifications and component status with digital photography for service records.
Met with customer and completed rework of return duct in the washer/dryer room. Accessed wall section to modify existing plumbing infrastructure, including proper routing of PVC drain connections and color-coded water supply lines (red/hot, blue/cold). Ensured proper installation of valve box and all plumbing fittings according to new construction specifications.
Conducted full HVAC system replacement including removal of aging furnace and outdoor condenser unit. Installed new equipment with updated connections to existing ductwork and refrigerant lines. System replacement included necessary electrical modifications and verification of proper operation under winter conditions.
Responded to emergency service call for 16-year-old Lennox furnace exhibiting intermittent operation with error code E223. Performed combustion analysis with gas analyzer, measuring 6.4% O2 and 17 ppm CO. Determined issue was related to flame sensor/ignition sequence and restored proper operation.
Responded to service call regarding malfunctioning exhaust fan in a commercial facility. Upon inspection, found an aging exhaust ventilation system with significant dust accumulation and deterioration on the fan unit mounted to concrete block wall. Fan motor was non-operational and housing showed considerable wear with debris buildup on blades, requiring complete replacement.
Completed furnace retrofit in basement utility area, installing a new Armstrong Air Ultra V furnace with appropriate PVC intake/exhaust ventilation system. All connections to existing ductwork were properly sealed and system was tested for proper operation after installation.
Completed fall heating maintenance service. Performed combustion analysis using Testo 310 analyzer, which showed readings of 7.5% Oâ‚‚ and 7 ppm CO, indicating proper combustion efficiency and safe carbon monoxide levels. System is operating within manufacturer specifications.
Performed comprehensive oil boiler clean and check service. Conducted combustion analysis using Testo 327-1 analyzer, confirming proper flue gas readings with CO levels at 2 PPM and stack temperature within normal parameters. System is operating efficiently with no issues detected.
Performed assessment for gas line piping installation to accommodate a gas stove in a residence currently under renovation. Inspected existing structure, including exposed framing, electrical pathways, and floor substrate to determine optimal routing for new gas line. Identified suitable connection points and mounting locations for secure gas piping installation.
Responded to no heat call on furnace less than 10 years old. Performed combustion analysis with Testo 310 analyzer, readings showed Oâ‚‚ at 9.0% and CO at 12 ppm, indicating proper combustion within manufacturer specifications. System restored to normal operation.
Responded to no-heat call for 5-year-old furnace. Performed combustion analysis using Testo 310 analyzer, which revealed Oâ‚‚ level of 9.0% and CO level of 14 ppm. Restored proper operation of heating system.
Opened wall behind dishwasher to investigate suspected furnco leak, utilized camera inspection to identify broken drain tile, then performed jackhammer work to access and repair damaged drain section. Customer confirmed partial payment arrangement has been made.
Responded to no-heat call for 34-year-old Carrier Weathermaker 8000 with variable speed blower. Performed combustion analysis using Testo 310 analyzer, which revealed Oâ‚‚ levels at 8.9% and CO at 6 ppm, indicating acceptable combustion operation. Restored heating functionality and verified safe operation of this aging natural gas system.
Conducted comprehensive inspection of existing dual Geothermal systems for conversion to Gas/AC configuration. Evaluated current SPECTRA furnace unit with associated control module and electrical connections in basement utility area. Documented system layout and ductwork configuration to prepare detailed replacement estimate for two complete HVAC system conversions.
Performed scheduled fall/winter maintenance inspection. Documented structural concerns including a significant vertical crack in the interior wall and noted wear on exterior panels. Photographic evidence collected for documentation purposes.