Akron 44320 has the kind of housing where the age of the furnace does not always tell you the age of the system around it. Around Highland Square, Edgewood, Maple Valley, and other parts of West Akron, established colonials and mid-century homes can have decades of heating, cooling, plumbing, and remodeling work layered together. You may find a newer furnace connected to legacy ductwork, an older radiator system still doing its job, or forced-air equipment added during a previous renovation.

Lakes Heating & Air Conditioning works throughout Akron, OH 44320 helping homeowners sort through those combinations. Whether the problem is an aging gas furnace, dry winter air, plumbing that has been updated in stages, or an AC system struggling to move air through an older layout, we look at how the whole house is working before recommending the next step. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.

Older West Akron Homes Give Us More To Look At

The established housing stock is one of the things that makes 44320 different. Historic homes, older colonials, and mid-century properties are common, and many have conventional basements where several generations of mechanical work can be visible in the same room.

Legacy ductwork and radiator systems are still part of the picture in this area. Some homes have been converted to forced air, while others received newer heating or cooling equipment without completely changing the original distribution system. Enclosed rooms and older architectural layouts can also affect how air moves from one part of the house to another.

That is why we do not treat a comfort problem in Highland Square exactly like one in a newer home somewhere else. The layout, previous upgrades, and original construction can all point us toward the real cause.

Plumbing Repairs Often Start With Understanding What Changed

In an established Edgewood or Maple Valley home, the plumbing you can see may be much newer than what is behind the walls. Kitchens, bathrooms, water heaters, fixtures, and supply lines are often updated at different times, which can leave a mix of old and new components working together.

Conventional basements give us a useful place to start. Water heaters, gas lines, drains, and other utility connections often come together downstairs, making it easier to see where previous work was completed and where older sections remain.

Our plumbing services include:

  • Plumbing installation
  • Plumbing repair
  • Water heaters
  • Drain cleaning
  • Bathroom remodel plumbing
  • Faucet installation and repair
  • Leak detection and repair
  • Gas line installation
  • Garbage disposals
  • Toilets
  • Sinks
  • Sump pumps

A recurring slow drain, a change in water pressure, or hot water that does not last as long as it used to may be the first sign of a larger issue. We trace the problem before replacing parts that may not be causing it.

Indoor Air Quality Matters In Older, Enclosed Spaces

Older West Akron homes often have enclosed rooms and layouts that behave differently from newer open-concept construction. Add replacement windows, insulation improvements, and HVAC upgrades over time, and the way the house handles moisture and fresh air can change considerably.

The local climate adds another challenge. Warm, humid summers can leave lower levels or closed rooms feeling damp, while steady furnace operation through winter can make indoor air dry. Those opposite conditions are why humidity control is often part of the comfort conversation in 44320.

We install and service:

  • Air cleaners
  • Air scrubbers
  • Air purifiers
  • Humidifiers
  • Dehumidifiers
  • Thermostats
  • Carbon monoxide detection
  • Air ducts and ductwork

Air cleaners and scrubbers can help with filtration, while whole-home humidifiers and dehumidifiers address seasonal moisture throughout the house. When one area still feels different from another, we also check the ductwork because poor circulation can affect both air quality and temperature.

Heating Service For West Akron's Long Winter Runs

Northeast Ohio winters bring cold temperatures, snow, and lake-effect influence that can keep heating equipment running for long stretches. That is when weaknesses in older furnaces, legacy duct systems, or converted heating layouts become easier to notice.

Around 44320, we may be working on a traditional gas furnace in one house and a radiator or updated forced-air system in another. Older colonials can also have rooms that respond differently because of the original floor plan, especially when a heating system has been changed without completely redesigning how heat is distributed.

Our heating services include:

When part of a Highland Square home stays colder than the rest, we look at the furnace along with the ductwork, controls, airflow, and distribution. In a house with legacy equipment, the issue may be tied to the way the system has evolved over decades rather than one failed component.

AC Service For Humid Akron Summers

Warm, humid summers can put older cooling layouts to the test, especially in homes where central air was added after the original construction. Around Highland Square and the western Akron corridors, the cooling system may be working through ductwork that was designed around a different generation of equipment.

That can show up as warmer upstairs rooms, longer run times, or certain areas that never receive the same airflow. In older colonials and mid-century homes, enclosed rooms and previous renovations can also make one side of the house respond differently than another.

Lakes provides:

We check equipment performance alongside return airflow, duct condition, and the way conditioned air moves through the floor plan. High-efficiency cooling equipment can be a good upgrade, but it still needs the rest of the system to support it.

Service For The Layered Systems Found In Akron 44320

Highland Square, Edgewood, Maple Valley, and the surrounding West Akron neighborhoods include homes that have been maintained and changed over several generations. Legacy ductwork may serve newer equipment. Radiator systems may still be active in one property while a forced-air conversion sits a few doors away. Plumbing and indoor air upgrades can add another layer to that mechanical history.

Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44320. Call (330) 536-1276 or contact us online today to schedule service.

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in February 2026.

The most recent job was on February 5, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 948 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Akron, OH - Completed fall maintenance on heating system. Performed combustion analysis using Bacharach Fyrite INSIGHT analyzer, confirming optimal operation with 96.9% efficiency, 8.2% O2, 7.2% CO2, and CO at 26 ppm - all within acceptable parameters for natural gas equipment.
Nick D.
Nick D. Checked in
Completed fall maintenance on heating system. Performed combustion analysis using Bacharach Fyrite INSIGHT analyzer, confirming optimal operation with 96.9% efficiency, 8.2% O2, 7.2% CO2, and CO at 26 ppm - all within acceptable parameters for natural gas equipment.
Akron, OH 44303
Akron, OH - Completed furnace inspection with combustion analysis using Sauermann gas analyzer. System testing showed furnace operating at 88.5% efficiency (eta+) with acceptable CO levels at 31ppm and CO2 at 7.85%. All readings within normal parameters, confirming proper combustion performance.
Jake T.
Jake T. Checked in
Completed furnace inspection with combustion analysis using Sauermann gas analyzer. System testing showed furnace operating at 88.5% efficiency (eta+) with acceptable CO levels at 31ppm and CO2 at 7.85%. All readings within normal parameters, confirming proper combustion performance.
Akron, OH 44321
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Deepak R.
Deepak R. Checked in
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Akron, OH 44305
Akron, OH - Diagnosed 30-year-old residential furnace exhibiting short cycling issue. Visual inspection revealed significant corrosion and wear on blower motor assembly with deteriorated wiring connections. Recommended replacement due to age and condition of equipment.
Tom M.
Tom M. Checked in
Diagnosed 30-year-old residential furnace exhibiting short cycling issue. Visual inspection revealed significant corrosion and wear on blower motor assembly with deteriorated wiring connections. Recommended replacement due to age and condition of equipment.
Akron, OH 44313
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Clay B.
Clay B. Checked in
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Akron, OH 44310
Akron, OH - Replaced defective blower motor under warranty (labor only). Performed gas combustion analysis with Sauermann analyzer, verifying proper system operation with readings showing 88.8% efficiency, O2 at 6.60%, CO at 5 ppm, and CO2 at 8.02%.
Jake T.
Jake T. Checked in
Replaced defective blower motor under warranty (labor only). Performed gas combustion analysis with Sauermann analyzer, verifying proper system operation with readings showing 88.8% efficiency, O2 at 6.60%, CO at 5 ppm, and CO2 at 8.02%.
Akron, OH 44312
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Nick D.
Nick D. Checked in
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Akron, OH 44333
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Brynn L.
Brynn L. Checked in
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Akron, OH 44314
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Clay B.
Clay B. Checked in
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Akron, OH 44312
Akron, OH - Successfully installed a new Lennox furnace unit in the basement utility room, connecting it to the existing ductwork system. Ensured proper ventilation with metal ductwork extending upward and horizontally across the ceiling area, and verified all connections were secure and functioning correctly.
Blake C.
Blake C. Checked in
Successfully installed a new Lennox furnace unit in the basement utility room, connecting it to the existing ductwork system. Ensured proper ventilation with metal ductwork extending upward and horizontally across the ceiling area, and verified all connections were secure and functioning correctly.
Akron, OH 44314
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Deepak R.
Deepak R. Checked in
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Akron, OH 44319
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Brynn L.
Brynn L. Checked in
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Akron, OH 44319
Akron, OH - Responded to service call for furnace with startup issues. Performed combustion analysis with digital analyzer, confirming readings of 8 PPM CO, 12 PPM CO-CF, at 489% excess air and 79% efficiency. System now operating correctly after adjustment.
Zack W.
Zack W. Checked in
Responded to service call for furnace with startup issues. Performed combustion analysis with digital analyzer, confirming readings of 8 PPM CO, 12 PPM CO-CF, at 489% excess air and 79% efficiency. System now operating correctly after adjustment.
Akron, OH 44319
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Brad M.
Brad M. Checked in
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Akron, OH 44312
Akron, OH - Performed scheduled heating maintenance service and conducted combustion analysis using Bacharach analyzer. System tested with readings of 8.7% oxygen and 5ppm carbon monoxide, indicating proper combustion within acceptable safety parameters.
Joshua L.
Joshua L. Checked in
Performed scheduled heating maintenance service and conducted combustion analysis using Bacharach analyzer. System tested with readings of 8.7% oxygen and 5ppm carbon monoxide, indicating proper combustion within acceptable safety parameters.
Akron, OH 44333
Akron, OH - Conducted comprehensive evaluation of 6 RTUs as requested. During inspection, documented belt drive system on one unit showing signs of wear with visible dust accumulation and slight corrosion on the pulley mechanism. Visual assessment indicates routine maintenance may be required to address potential belt system deterioration.
Deepak R.
Deepak R. Checked in
Conducted comprehensive evaluation of 6 RTUs as requested. During inspection, documented belt drive system on one unit showing signs of wear with visible dust accumulation and slight corrosion on the pulley mechanism. Visual assessment indicates routine maintenance may be required to address potential belt system deterioration.
Akron, OH 44310
Akron, OH - Performed annual maintenance on 12-year-old furnace. Conducted combustion analysis with Testo 310 gas analyzer, confirming CO levels at 1.5 ppm and 0 ppm, which are within safe operating parameters.
Brynn L.
Brynn L. Checked in
Performed annual maintenance on 12-year-old furnace. Conducted combustion analysis with Testo 310 gas analyzer, confirming CO levels at 1.5 ppm and 0 ppm, which are within safe operating parameters.
Akron, OH 44312
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Brynn L.
Brynn L. Checked in
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Akron, OH 44319
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Brynn L.
Brynn L. Checked in
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Akron, OH 44301
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Brynn L.
Brynn L. Checked in
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Akron, OH 44319

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.