Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, AC & Plumbing Services in Akron, OH 44321

Akron 44321 has a suburban feel, but the homes are far from uniform. Around the Western Akron and Fairlawn borders, you will find mid-century ranches, split-levels, traditional homes, and newer development sharing the same service area. Closer to Copley Circle, established neighborhoods add another layer of housing styles and mechanical systems that have been updated over several decades.

That variety matters when a furnace starts short-cycling, an upstairs room stays warm, or a leak shows up right before you are headed out of town. Lakes Heating & Air Conditioning works throughout 44321 helping homeowners sort out heating, cooling, plumbing, and indoor air quality problems based on the way the home is actually built. Call (330) 536-1276 or contact Lakes Heating & Air Conditioning online to schedule service.

Split-Levels And Ranches Around Copley Circle Have Their Own Comfort Patterns

Many homes in 44321 were built during the middle and later decades of the twentieth century. Ranches and split-levels are common, along with traditional homes that have conventional basements and standard forced-air ductwork.

Those layouts create some familiar service calls. A split-level may have one section that heats faster than another. A ranch can develop weak airflow at the end of a longer duct run. Homes that have gone through furnace replacements, central AC upgrades, window changes, or remodeling may no longer behave exactly the way the original HVAC system was designed to handle.

We start by looking at how the whole setup fits together. The age of the furnace matters, but so does the ductwork, thermostat location, basement layout, and whatever has changed in the house over the years.

Plumbing Problems Can Interrupt A Household Fast

Traditional basements are common in this part of Akron, which means much of the plumbing and HVAC infrastructure often comes together downstairs. Water heaters, gas lines, drain connections, sump equipment, furnaces, and ductwork may all be located within the same mechanical area.

In an established home near the Western Akron side of 44321, a newer fixture or water heater may still connect to older portions of the system. In a later home closer to the Fairlawn border, the plumbing may be more standardized but can still show the effects of years of repairs and remodeling.

Our plumbing services include:

  • Plumbing installation
  • Plumbing repair
  • Water heaters
  • Drain cleaning
  • Bathroom remodel plumbing
  • Faucet installation and repair
  • Leak detection and repair
  • Gas line installation
  • Garbage disposals
  • Toilets
  • Sinks
  • Sump pumps

An unexpected leak can become a major disruption quickly. We check where the water is coming from, how that section ties into the rest of the plumbing, and whether the visible problem is the full issue or only the first sign of something larger.

Tree-Lined Neighborhoods Change The Indoor Air Conversation

Mature trees are part of the character around Western Akron, the Fairlawn side of 44321, and the residential areas near Sand Run Metro Park. They also mean spring pollen and seasonal allergens can become noticeable indoors once the HVAC system starts circulating more air.

Older ductwork can make filtration less consistent from room to room, while newer homes may hold airborne particles differently because tighter construction allows less natural air exchange. Summer humidity and dry winter air add two more seasonal challenges.

We install and service:

  • Air cleaners
  • Air scrubbers
  • Air purifiers
  • Humidifiers
  • Dehumidifiers
  • Thermostats
  • Carbon monoxide detection
  • Air ducts and ductwork

Air scrubbers are a strong fit for homes where seasonal allergens are a recurring concern. Humidifiers can help through long winter heating cycles, while dehumidifiers make more sense when summer moisture starts settling into lower levels or enclosed rooms.

Older Gas Furnaces Work Hard Through Akron Winters

Freezing temperatures and Great Lakes weather can keep a furnace running steadily for days. That is when aging equipment tends to reveal problems that were easy to overlook during mild fall weather.

Legacy gas furnaces are still part of the housing mix in 44321, especially in established neighborhoods. Replacing the furnace can improve efficiency, but the rest of the heating system still matters. A newer unit connected to restricted or poorly balanced ductwork may continue to leave certain rooms uncomfortable.

Our heating services include:

In a split-level near Copley Circle, we may find the furnace producing plenty of heat while one level receives less of it. In a traditional home nearer Fairlawn, the issue might be tied to controls, airflow, or an older distribution setup. We diagnose the pattern before recommending replacement.

Summer Cooling Near Sand Run Is About Temperature And Moisture

Warm, humid summers can make cooling problems stand out quickly. Homes near Sand Run Metro Park and other wooded sections of 44321 can feel uncomfortable even when the thermostat says the AC is keeping up.

Mid-century ranches and split-levels may have central air systems that were replaced without major duct changes. Larger or newer homes can face a different challenge, with longer runs serving rooms farther from the main equipment.

Lakes provides:

We pay attention to how long the system runs, how well it removes moisture, and whether conditioned air is actually reaching every part of the home. A high-efficiency AC system can help, but it cannot make up for a distribution problem that has been there for years.

Local HVAC And Plumbing Service For Akron 44321

A mid-century ranch near the Western Akron side of 44321 does not necessarily need the same solution as a split-level near Copley Circle or a newer property closer to Fairlawn. Legacy furnaces, conventional basements, central air upgrades, mature duct systems, and indoor air quality equipment all show up across the ZIP code.

Lakes Heating & Air Conditioning provides heating, air conditioning, plumbing, indoor air quality, and commercial HVAC services throughout Akron, OH 44321. Call (330) 536-1276 or contact us online today to schedule service.

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026.

The most recent job was on October 19, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 948 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Brandon F.
Brandon F. Checked in
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Akron, OH 44333
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Roderick H.
Roderick H. Checked in
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Akron, OH 44319
Akron, OH - Performed annual heating maintenance on a natural gas furnace of unknown age, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a calibrated flue gas analyzer, recording O2 at 8.21%, CO at 4 ppm, CO2 at 7.13%, and combustion efficiency of 88.5%, confirming safe operation with CO well within acceptable limits and the system operating within normal parameters.
Jake T.
Jake T. Checked in
Performed annual heating maintenance on a natural gas furnace of unknown age, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a calibrated flue gas analyzer, recording O2 at 8.21%, CO at 4 ppm, CO2 at 7.13%, and combustion efficiency of 88.5%, confirming safe operation with CO well within acceptable limits and the system operating within normal parameters.
Akron, OH 44333
Akron, OH - Performed seasonal heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a gas analyzer that recorded O2 at 7.03%, CO at 12 ppm, and CO2 at 7.79%, confirming safe operation within acceptable parameters. Replaced the filtration components with one 213 media filter and one #35 water panel, and verified proper system operation upon completion.
Jake T.
Jake T. Checked in
Performed seasonal heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a gas analyzer that recorded O2 at 7.03%, CO at 12 ppm, and CO2 at 7.79%, confirming safe operation within acceptable parameters. Replaced the filtration components with one 213 media filter and one #35 water panel, and verified proper system operation upon completion.
Akron, OH 44333
Akron, OH - Relocated the condenser lineset and associated electrical to the new unit position on the exterior wall. Rerouted the insulated refrigerant lines and flexible whip from the outdoor disconnect to the condenser, secured them to the siding, and verified all connections are properly supported and weather-protected.
Ryan L.
Ryan L. Checked in
Relocated the condenser lineset and associated electrical to the new unit position on the exterior wall. Rerouted the insulated refrigerant lines and flexible whip from the outdoor disconnect to the condenser, secured them to the siding, and verified all connections are properly supported and weather-protected.
Akron, OH 44319
Akron, OH - Performed routine annual maintenance and tune-up on the gas furnace, which was operating properly upon arrival. Completed a combustion analysis using a flue gas analyzer, recording O2 at 8.82%, CO at 19 ppm, and CO2 at 6.79% on natural gas, with CO levels within acceptable limits. The system was left operating normally with no repairs required.
Jake T.
Jake T. Checked in
Performed routine annual maintenance and tune-up on the gas furnace, which was operating properly upon arrival. Completed a combustion analysis using a flue gas analyzer, recording O2 at 8.82%, CO at 19 ppm, and CO2 at 6.79% on natural gas, with CO levels within acceptable limits. The system was left operating normally with no repairs required.
Akron, OH 44313
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Roderick H.
Roderick H. Checked in
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Akron, OH 44310
Akron, OH - Performed annual preventive maintenance on a 16-year-old natural gas furnace, including a combustion analysis with a calibrated Bacharach analyzer. Final readings were within acceptable parameters: CO at 15 ppm, Oâ‚‚ at 9.4%, COâ‚‚ at 6.5%, and steady-state efficiency of 97.3%, confirming safe and proper combustion.
Maddex H.
Maddex H. Checked in
Performed annual preventive maintenance on a 16-year-old natural gas furnace, including a combustion analysis with a calibrated Bacharach analyzer. Final readings were within acceptable parameters: CO at 15 ppm, Oâ‚‚ at 9.4%, COâ‚‚ at 6.5%, and steady-state efficiency of 97.3%, confirming safe and proper combustion.
Akron, OH 44313
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Denver H.
Denver H. Checked in
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Akron, OH 44310
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Jim C.
Jim C. Checked in
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.
Akron, OH 44307
Performed scheduled commercial heating maintenance on an Armstrong Air upright gas furnace, inspecting the cabinet, flue and condensate piping, gas line with shutoff valve, and connected supply ductwork. Noted heavy condensation on the galvanized duct surface with a measured surface temperature of 55.8°F, along with peeling foil tape at a duct seam, indicating a need for insulation and seam sealing to prevent moisture accumulation and potential damage. Recommend re-sealing the duct seams and insulating the affected ductwork.
Performed scheduled commercial heating maintenance on an Armstrong Air upright gas furnace, inspecting the cabinet, flue and condensate piping, gas line with shutoff valve, and connected supply ductwork. Noted heavy condensation on the galvanized duct surface with a measured surface temperature of 55.8°F, along with peeling foil tape at a duct seam, indicating a need for insulation and seam sealing to prevent moisture accumulation and potential damage. Recommend re-sealing the duct seams and insulating the affected ductwork.
Roderick H.
Roderick H. Checked in
Performed scheduled commercial heating maintenance on an Armstrong Air upright gas furnace, inspecting the cabinet, flue and condensate piping, gas line with shutoff valve, and connected supply ductwork. Noted heavy condensation on the galvanized duct surface with a measured surface temperature of 55.8°F, along with peeling foil tape at a duct seam, indicating a need for insulation and seam sealing to prevent moisture accumulation and potential damage. Recommend re-sealing the duct seams and insulating the affected ductwork.
Akron, OH 44310
Akron, OH - Performed annual heating maintenance on a 10-year-old basement furnace, including inspection of the combustion system and a flue gas analysis with a Bacharach combustion analyzer. Readings on natural gas showed O2 at 7.5%, CO at 92 ppm, CO2 at 7.6%, and combustion efficiency of 79.6%, which were documented for the equipment record.
Maddex H.
Maddex H. Checked in
Performed annual heating maintenance on a 10-year-old basement furnace, including inspection of the combustion system and a flue gas analysis with a Bacharach combustion analyzer. Readings on natural gas showed O2 at 7.5%, CO at 92 ppm, CO2 at 7.6%, and combustion efficiency of 79.6%, which were documented for the equipment record.
Akron, OH 44314
Akron, OH - Performed fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer. Readings were within normal operating range at O2 6.5%, CO2 8.1%, CO 12 ppm, and steady-state efficiency of 82.3%, confirming proper combustion and safe operation of the appliance.
Maddex H.
Maddex H. Checked in
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer. Readings were within normal operating range at O2 6.5%, CO2 8.1%, CO 12 ppm, and steady-state efficiency of 82.3%, confirming proper combustion and safe operation of the appliance.
Akron, OH 44310
Akron, OH - Responded to a no-heat complaint on the main floor of a hydronic heating system, with only the upper level receiving heat. Inspected the boiler, circulator, motorized zone valves, and associated control wiring and piping in the mechanical closet, noting surface corrosion and dust accumulation on the boiler cabinet. Evaluated zone valve and control operation to isolate the cause of the lost main-floor heat call, and documented system conditions with photos for further recommendations.
Zack W.
Zack W. Checked in
Responded to a no-heat complaint on the main floor of a hydronic heating system, with only the upper level receiving heat. Inspected the boiler, circulator, motorized zone valves, and associated control wiring and piping in the mechanical closet, noting surface corrosion and dust accumulation on the boiler cabinet. Evaluated zone valve and control operation to isolate the cause of the lost main-floor heat call, and documented system conditions with photos for further recommendations.
Akron, OH 44319
Performed a complete furnace tune-up, including cleaning and inspecting the inducer blower assembly, pressure switches, gas valve, flue connections, and associated wiring, with no visible damage, rust, or abnormalities noted. Conducted a combustion analysis on the flue gases, recording 8.9% O2, 2 ppm CO, and 3 ppm CO-AF with 65.8% excess air, confirming safe and proper operation. Furnace is operating within normal parameters, and the customer was enrolled in the maintenance agreement with a copy provided.
Performed a complete furnace tune-up, including cleaning and inspecting the inducer blower assembly, pressure switches, gas valve, flue connections, and associated wiring, with no visible damage, rust, or abnormalities noted. Conducted a combustion analysis on the flue gases, recording 8.9% O2, 2 ppm CO, and 3 ppm CO-AF with 65.8% excess air, confirming safe and proper operation. Furnace is operating within normal parameters, and the customer was enrolled in the maintenance agreement with a copy provided.
Zack W.
Zack W. Checked in
Performed a complete furnace tune-up, including cleaning and inspecting the inducer blower assembly, pressure switches, gas valve, flue connections, and associated wiring, with no visible damage, rust, or abnormalities noted. Conducted a combustion analysis on the flue gases, recording 8.9% O2, 2 ppm CO, and 3 ppm CO-AF with 65.8% excess air, confirming safe and proper operation. Furnace is operating within normal parameters, and the customer was enrolled in the maintenance agreement with a copy provided.
Akron, OH 44312
Removed the existing garage furnace and installed a new replacement unit, with associated ductwork modifications to tie the supply and return into the existing distribution system. Cut access openings in the garage wall drywall and disturbed the R-19 fiberglass batt insulation to route and secure the duct and furnace connections. Left the wall cavities open for insulation repair and drywall patching by the finishing trades.
Removed the existing garage furnace and installed a new replacement unit, with associated ductwork modifications to tie the supply and return into the existing distribution system. Cut access openings in the garage wall drywall and disturbed the R-19 fiberglass batt insulation to route and secure the duct and furnace connections. Left the wall cavities open for insulation repair and drywall patching by the finishing trades.
Denver H.
Denver H. Checked in
Removed the existing garage furnace and installed a new replacement unit, with associated ductwork modifications to tie the supply and return into the existing distribution system. Cut access openings in the garage wall drywall and disturbed the R-19 fiberglass batt insulation to route and secure the duct and furnace connections. Left the wall cavities open for insulation repair and drywall patching by the finishing trades.
Akron, OH 44333
Completed A/C and coil retrofit installation on a residential split system charged with R-454B refrigerant. Verified system performance with a digital manifold gauge set, recording 116.7 psig suction pressure, 283.3 psig discharge pressure, 20.3°F superheat, and 6.5°F subcooling, with saturation temperatures of 43.9°F vapor and 95.0°F liquid. Confirmed charge and operating readings are within acceptable range for system operation.
Completed A/C and coil retrofit installation on a residential split system charged with R-454B refrigerant. Verified system performance with a digital manifold gauge set, recording 116.7 psig suction pressure, 283.3 psig discharge pressure, 20.3°F superheat, and 6.5°F subcooling, with saturation temperatures of 43.9°F vapor and 95.0°F liquid. Confirmed charge and operating readings are within acceptable range for system operation.
Ryan L.
Ryan L. Checked in
Completed A/C and coil retrofit installation on a residential split system charged with R-454B refrigerant. Verified system performance with a digital manifold gauge set, recording 116.7 psig suction pressure, 283.3 psig discharge pressure, 20.3°F superheat, and 6.5°F subcooling, with saturation temperatures of 43.9°F vapor and 95.0°F liquid. Confirmed charge and operating readings are within acceptable range for system operation.
Akron, OH 44319
Akron, OH - Performed fall heating maintenance, including a combustion analysis on the natural gas furnace using a calibrated flue gas analyzer. Readings showed O2 at 7.08%, CO2 at 7.75%, and CO at 11 ppm, confirming clean combustion and safe operation within acceptable limits.
Jake T.
Jake T. Checked in
Performed fall heating maintenance, including a combustion analysis on the natural gas furnace using a calibrated flue gas analyzer. Readings showed O2 at 7.08%, CO2 at 7.75%, and CO at 11 ppm, confirming clean combustion and safe operation within acceptable limits.
Akron, OH 44319
Performed seasonal heating maintenance on an 11-year-old natural gas furnace, removing the upper access panel to inspect the burner compartment, gas valve assembly, wiring harness, and blower motor. Conducted flue gas combustion analysis, recording 6.2% O2, 26 ppm CO, and 37 ppm CO air-free at 37.5% excess air, confirming combustion within acceptable parameters. Noted dust accumulation and light corrosion on the cabinet floor of the interior compartment, which should be monitored at future visits.
Performed seasonal heating maintenance on an 11-year-old natural gas furnace, removing the upper access panel to inspect the burner compartment, gas valve assembly, wiring harness, and blower motor. Conducted flue gas combustion analysis, recording 6.2% O2, 26 ppm CO, and 37 ppm CO air-free at 37.5% excess air, confirming combustion within acceptable parameters. Noted dust accumulation and light corrosion on the cabinet floor of the interior compartment, which should be monitored at future visits.
Zack W.
Zack W. Checked in
Performed seasonal heating maintenance on an 11-year-old natural gas furnace, removing the upper access panel to inspect the burner compartment, gas valve assembly, wiring harness, and blower motor. Conducted flue gas combustion analysis, recording 6.2% O2, 26 ppm CO, and 37 ppm CO air-free at 37.5% excess air, confirming combustion within acceptable parameters. Noted dust accumulation and light corrosion on the cabinet floor of the interior compartment, which should be monitored at future visits.
Akron, OH 44312
Completed furnace retrofit installation in mechanical room. Removed existing heating unit and installed new gray metal furnace with proper ductwork connections to existing HVAC system. Ensured all supply and return air ducts were properly sealed and secured to new unit. Verified clearances around equipment meet manufacturer specifications and local code requirements. Tested system operation and confirmed proper airflow throughout distribution system.
Completed furnace retrofit installation in mechanical room. Removed existing heating unit and installed new gray metal furnace with proper ductwork connections to existing HVAC system. Ensured all supply and return air ducts were properly sealed and secured to new unit. Verified clearances around equipment meet manufacturer specifications and local code requirements. Tested system operation and confirmed proper airflow throughout distribution system.
Mike S.
Mike S. Checked in
Completed furnace retrofit installation in mechanical room. Removed existing heating unit and installed new gray metal furnace with proper ductwork connections to existing HVAC system. Ensured all supply and return air ducts were properly sealed and secured to new unit. Verified clearances around equipment meet manufacturer specifications and local code requirements. Tested system operation and confirmed proper airflow throughout distribution system.
Akron, OH 44319

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.