Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in August 2026. The most recent job was on August 12, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Replaced failed condenser fan motors, blades, and capacitors on commercial HVAC unit. Removed corroded fan assembly showing significant rust on mounting hardware and hub, installed new motor assemblies with factory-spec blades, and verified proper rotation and airflow upon startup.
Responded to callback for unresolved gas leak on furnace supply line. Upon arrival, inspected gas piping assembly and fittings at furnace connection point. Located active leak at threaded union connection between galvanized steel pipe and brass valve assembly. Applied leak detection solution to verify exact leak location at threaded joint. Shut off gas supply via red-handled ball valve, depressurized line, and disassembled union fitting. Cleaned threads, applied appropriate pipe thread sealant, and reassembled connection to manufacturer specifications. Pressurized system and performed leak check with soap solution—no leaks detected. Restored gas supply and verified proper furnace operation.
Conducted site assessment for gas line installation to service pool heater. Evaluated routing requirements through crawlspace and basement areas, documenting existing structural conditions including exposed floor joists, storage configurations, and available pathways for pipe installation. Photographed proposed gas line route and identified necessary access points for future installation work.
Completed full HVAC system retrofit including outdoor Lennox air conditioning condenser unit and indoor furnace with associated ductwork. The exterior condenser was professionally mounted on a stable pad against the building exterior with proper electrical connections routed from the existing meter, while the indoor furnace installation featured new metal ductwork, air handling components, and proper integration with the existing water heater and utility infrastructure in the basement mechanical room.
Responded to service call for 16-year-old AC system with outside condenser running continuously but interior furnace not engaging. Verified 120V power supply and maintenance switch both functioning properly. Diagnosed lack of power at control board despite board fuse testing good; control board indicator lights not illuminating, confirming board failure. Documented equipment specifications including serial number 8403K16236 from furnace nameplate for replacement parts ordering.
Responded to service call for non-operational commercial A/C unit. Upon inspection, diagnosed system failure and performed necessary repairs to restore unit to proper working condition. Verified operational status of compressor, fan assembly, and electrical components, replaced air filters, and confirmed system functionality with all components operating within normal parameters.
Completed full HVAC system retrofit in basement mechanical room, including new furnace and air conditioning equipment installation. Installed furnace unit with properly configured supply and return ductwork, mounted vertical plenum with integrated controls, and ran PVC condensate drain lines in accordance with manufacturer specifications. All ductwork secured to ceiling joists with appropriate fasteners, system tested and verified operational upon completion.
Completed full HVAC system retrofit including replacement of indoor furnace unit and outdoor air conditioning condenser. Installed new beige-cased furnace in basement utility area with proper venting using white PVC piping and insulated connections. Configured copper refrigerant lines and white ductwork for optimal airflow. Positioned new white vertical condenser unit on concrete pad against building exterior with finned coil heat exchanger. Connected unit to building electrical system using gray conduit and routed white PVC condensate drainage line through stone foundation. All components installed per manufacturer specifications and local code requirements. System tested and confirmed operational.
Completed routine commercial cooling maintenance on rooftop condensing unit. Performed standard service procedures including cleaning condenser coils with water flush, inspecting fan motor and blade assembly, and checking refrigerant operation. Accessed air handler compartment and noted filter condition and interior cleanliness. All components operating within normal parameters upon completion of scheduled maintenance visit.
Completed full HVAC system retrofit including furnace and air conditioning replacement. Installed new equipment with proper ductwork integration, ensured all refrigerant lines were properly evacuated to 325 microns as verified by vacuum gauge testing, and confirmed system achieved target vacuum levels for optimal performance. All venting, electrical connections, and condensate management systems were installed to manufacturer specifications and local code requirements.
Completed installation of ductwork and flue piping on second floor mechanical space for commercial new construction project. Installed rigid and flexible ductwork with proper support brackets and strapping, routed PVC condensate drain lines, and ensured all mechanical components were properly secured and positioned according to specifications.
Completed routine cooling maintenance on a 14-year-old ground-level air conditioning system scheduled for 8 AM appointment. Performed comprehensive inspection of outdoor condenser unit, checked electrical connections and conduit mounting, verified proper fan operation, and assessed overall system condition. Unit is approaching replacement age and customer has been advised regarding renewal timeline.
Performed scheduled commercial cooling maintenance on rooftop HVAC unit. Conducted electrical diagnostics using digital multimeter to test capacitor performance and verify proper voltage readings. Measured capacitor microfarad values to ensure component was operating within manufacturer specifications. All readings confirmed system components functioning correctly with no deficiencies noted.
Completed AC retrofit installation in basement location. Installed new air conditioning system with evaporator coil, integrating equipment with existing ductwork and utility infrastructure in exposed ceiling space. System tested and verified operational upon completion.
Replaced failed condenser fan motor and fan blade on commercial air conditioning unit. Upon arrival, removed protective grille to access condenser assembly and disconnected power supply. Extracted damaged motor and blade from mounting bracket, installed new replacement motor with proper electrical connections, and secured new fan blade to motor shaft. Restored power, tested unit operation to verify proper fan rotation and airflow, and confirmed system returned to normal cooling function. Reinstalled protective grille and cleared work area.
Performed comprehensive HVAC system inspection as requested. Conducted combustion analysis on natural gas heating equipment using calibrated gas analyzer, recording oxygen levels at 12.30% and 10.73% across multiple readings, carbon monoxide levels at 17 ppm and 9 ppm, and carbon dioxide levels at 4.84% and 5.71%, all within acceptable operating parameters. System operating safely with no immediate concerns identified.
Upon arrival, discovered evaporator coil completely frozen over. System requires defrost time before diagnosis can continue. Scheduled follow-up visit to assess underlying cause of freeze condition, which may include refrigerant charge issues, airflow restrictions, or thermostat malfunction.
Responded to service call for two separate sink issues in residential property. First location: master bedroom bathroom sink experiencing repeated drainage problems. Removed and cleaned faucet aerator to restore proper water flow, which had become restricted due to mineral deposit buildup. Second location: upstairs office/suite bathroom sink with stuck pop-up drain stopper assembly. Disassembled and freed the stuck stopper mechanism, cleaned drain components, and reassured proper operation of both the stopper and drainage system. Both fixtures tested and confirmed operational upon completion.
Completed full HVAC system retrofit in residential basement utility room, installing new Carrier furnace and outdoor condensing unit. Removed existing equipment and installed complete heating and cooling system with proper venting, electrical connections, condensate drainage via PVC piping, and refrigerant line set. Mounted exterior disconnect box, positioned condenser unit on concrete pad with proper clearances, and verified all connections for safe operation.
Completed maintenance service on 10-year-old air conditioning unit. Performed system diagnostics and utilized electronic charging scale to verify refrigerant levels and pressures were within manufacturer specifications. All measurements confirmed proper system operation and charge levels maintained at optimal parameters for continued efficient cooling performance.