Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026. The most recent job was on November 19, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Performed scheduled heating maintenance on a gas-fired boiler and conducted combustion analysis using a Testo 327-1 analyzer on natural gas flue gas. Initial readings showed 82.9% excess air, 10.1% O2, 27 ppm CO, and 52 ppm air-free CO; after adjustment, readings improved to 72.5% excess air, 9.4% O2, 13 ppm CO, and 24 ppm air-free CO, all within acceptable limits.
Inspected the water heater venting and found the vent piping corroded and rotted out at the original wall penetration, requiring replacement; an existing chimney liner was confirmed to be in place. Staged new stainless steel vent components, including elbow, straight sections, reducer, and wall thimble hardware, for installation per the manufacturer's horizontal venting and thimble installation procedures with proper slope and support.
Inspected the existing gas furnace installation and documented its current condition for replacement. With the access panel removed, the burner assembly, inducer motor, control board, pressure switch, and blower compartment were exposed and photographed, along with the PVC intake/exhaust piping, galvanized supply plenum and ductwork, and associated gas, electrical, and condensate connections. No evidence of frost, rust, or major damage was observed, and the unit's data and warning labels were documented to support equipment selection for the replacement estimate.
Replaced the existing furnace and hot water tank (HWT) as part of a weatherization assistance program upgrade, including associated venting and piping connections to the new equipment in the basement utility space. Installation was completed with the equipment secured and connected to the existing ductwork and water, gas, and electrical services.
Responded to a no-heat call on a gas-fired system over 10 years old and performed combustion analysis with a Testo 310 analyzer to evaluate flue gas readings and appliance operation. Documented analyzer results as part of the diagnostic process.
Responded to a no-heat call on a 5-year-old gas furnace located in the garage. Performed a combustion analysis on the unit while in operation using a Bacharach Fyrite InTech analyzer, with readings of 6.6% O2 and 22 ppm CO, indicating the furnace was firing and combustion was within normal range. Findings were reviewed with the customer prior to completion.
Performed a heating tune-up on a natural gas furnace, including a combustion analysis with a Bacharach Fyrite analyzer in run mode. Flue gas readings were O2 8.0%, CO2 7.3%, CO 46 ppm, and 79.3% combustion efficiency, documented for system performance records. The system was operating properly at the time of service.
Installed a complete HVAC split system consisting of an upright air handler with new galvanized supply ductwork, insulated refrigerant line set, and PVC condensate drain piping, paired with an outdoor condenser unit set on a concrete pad. Connected the condenser to a wall-mounted electrical disconnect with conduit and wiring, and verified the equipment was properly installed with no visible frost, rust, or damage.
Performed seasonal heating maintenance on two gas furnaces (8 and 5 years old). Conducted combustion analysis on natural gas operation, recording Oâ‚‚ at 7.5%, CO at 68 ppm, COâ‚‚ at 7.6%, stack temperature of 97°F, and combustion efficiency of 97.1%, confirming safe and efficient operation.
Performed seasonal heating maintenance on a gas-fired furnace and conducted a combustion analysis at the unit using a Bacharach analyzer. Readings recorded at 8.2% Oâ‚‚, 27 ppm CO, 7.2% COâ‚‚, and 80.3% combustion efficiency on natural gas, with CO within acceptable limits and no visible rust, frost, or damage on the furnace panel.
Performed annual heating maintenance on a 28-year-old natural gas furnace, including a combustion analysis of the flue gases. Readings showed O2 at 9.9%, CO2 at 6.2%, CO at 8 ppm, stack temperature of 88°F, and combustion efficiency of 98.4%, with CO within safe limits.
Responded to a complaint of the gas furnace intermittently starting and shutting down without delivering heat. Performed combustion analysis with a Testo 310 analyzer, recording 10.3% O2 and 23 ppm CO in the flue gases, to evaluate burner operation and combustion quality during the cycling condition.
Performed annual maintenance on a 10-year-old natural gas furnace, including inspection of the cabinet interior, wiring, transformer, and blower compartment, with no visible damage, rust, or frost noted. Conducted combustion analysis with a Bacharach analyzer, recording O2 at 6.0%, CO at 21 ppm, CO2 at 8.4%, and combustion efficiency of 97.5%, confirming the unit is operating within normal parameters.
Responded to a no-start complaint on a gas furnace and performed a combustion analysis using a Testo 310 analyzer, recording an Oâ‚‚ level of 8.5% and CO of 14 ppm, which are within acceptable operating limits. Thermostat replacement was evaluated as a possible cause of the no-start condition.
Retrofitted a Lennox upright gas furnace, connecting the gas supply with shutoff valve, PVC combustion venting, and a condensate drain line with trap and pump/float assembly. Sealed the supply and return plenum seams with foil tape and mounted the thermostat and control. Completed the electrical connections, and no visible signs of rust, frost, or physical damage were found on the equipment.
Performed annual heating maintenance on a gas furnace, including a combustion analysis with a Bacharach analyzer while operating on natural gas. Readings were within normal operating range: O2 at 8.6%, CO at 5 ppm, CO2 at 6.9%, and steady-state efficiency of 82.7%, confirming safe and efficient combustion.
Performed gas furnace maintenance, inspecting the blower motor compartment and low-voltage and line-voltage wiring connections, and verified secure terminations at the electrical component box. Conducted combustion analysis on natural gas, recording O2 at 6.5%, CO at 42 ppm, CO2 at 8.1%, stack temperature of 115°F, and combustion efficiency of 92.8%, confirming the unit is operating within acceptable parameters.
Responded to a no-heat call on a natural gas furnace; performed combustion analysis (O₂ 6.4%, CO 16 ppm) and diagnosed a failed blower motor/control module requiring replacement. Noted mineral deposit buildup on the PVC venting, and the replacement part has been quoted under warranty with an estimated 2–3 day availability.
Performed fall heating maintenance and combustion analysis on the natural gas furnace using a Bacharach analyzer. Readings recorded: O2 6.7%, CO 9 ppm, CO2 8.0%, and 74.8% efficiency, followed by a second test showing O2 5.3%, CO 4 ppm, CO2 8.8%, and 76.1% efficiency. CO levels remained well within safe limits, and the improved readings indicate more complete combustion after servicing.
Performed a fall tune-up and safety inspection on a 20-year-old Armstrong natural gas furnace with no reported issues. Completed a combustion analysis with a Bacharach analyzer, recording 90.1% efficiency, 3 ppm CO, 7.3% CO2, and 8.0% O2, all within acceptable operating parameters. The unit is operating normally and no repairs were required.