Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in June 2026. The most recent job was on June 17, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Responded to service call for 38-year-old air conditioning unit with minimal usage history. Upon arrival, performed standard diagnostic assessment of the system to identify operational issues. Inspected outdoor condenser unit and surrounding area, documenting equipment condition through photographic records. Due to the advanced age of the equipment and lack of specific symptom information provided at time of dispatch, conducted comprehensive visual inspection of accessible components. System evaluated and findings documented for service records.
Responded to no cooling call on commercial rooftop unit RTU #6 serving lanes 1-15. Found unit with heavily contaminated filter compartment containing excessive accumulation of lint, dust, and fibrous debris restricting airflow. Removed debris, cleaned filter housing, restored proper system operation, and verified unit cooling performance.
Performed comprehensive tune-up and cleaning service on multiple rooftop air conditioning systems. Thoroughly cleaned heavily soiled evaporator coils showing significant dust and debris accumulation with visible dark streaking and contamination throughout fin surfaces. Cleaned exterior condenser unit coils exhibiting substantial dirt buildup and darkened fin sections. Documented filter sizes for all units as requested and completed full system inspection to ensure proper operation of all air conditioning equipment.
Responded to service call for air conditioning system leaking water. Upon inspection, identified condensate drain line issue at exterior unit and verified proper drainage from evaporator coil in attic space. Cleared blockage in PVC condensate line, tested system operation, and confirmed leak was resolved with no further water discharge observed at outdoor condenser unit.
Completed spring preventive maintenance on commercial HVAC system per contract agreement. Performed comprehensive inspection of outdoor condenser units, documenting equipment condition with temperature differential measurements across refrigerant lines. Cleaned debris from condenser pads, inspected electrical connections, verified proper airflow through coil fins, and confirmed operational status of all units serving the facility.
Performed preventive maintenance on two 4-year-old air conditioning systems serving first and second floor zones. Completed standard maintenance protocol including filter inspection, system diagnostics, and operational testing on both units. Inspected humidifier unit and noted mineral buildup on mesh filter pad, documented condition with photos. Applied foil tape repairs to ductwork insulation where needed to maintain system efficiency. Both systems operating within normal parameters upon completion of maintenance visit.
Completed maintenance on 11-year-old air conditioning system and gas furnace in preparation for home sale. Performed comprehensive tune-up on both units, including combustion analysis of gas furnace which showed proper operation with oxygen levels at 6.8%, carbon monoxide at 18 ppm, efficiency at 92.4%, and carbon dioxide at 9.0%. All systems tested and operating within normal parameters.
Responded to callback for frozen unit. Upon arrival, connected digital manifold gauges and obtained system readings showing abnormal pressures and temperatures. Documented system conditions with diagnostic equipment displaying suction pressure of 32.3 PSI, discharge pressure of 207.0 PSI, and superheat reading of 15.8°F, indicating continued refrigerant flow issues or airflow restrictions causing freeze-up condition.
Performed comprehensive tune-up and safety inspection on residential heating and cooling system. Cleaned and evaluated air conditioning unit, inspected furnace components, and conducted combustion analysis on natural gas furnace using digital analyzer, which confirmed proper efficiency at 25.1% with acceptable oxygen levels at 15.5%, carbon monoxide at 7 ppm, and carbon dioxide at 8.0%.
Responded to service call for third-floor cooling issue in multi-zone AC system. Diagnosed failed Honeywell M847D-ZONE damper actuator motor preventing proper airflow to upper level while first and second floors operated normally. Replaced defective zone damper motor to restore full system functionality across all three zones.
Completed comprehensive cooling maintenance and tune-up on 15-year-old Lennox air conditioning system. Performed full system inspection of outdoor condensing unit and indoor air handler, checking refrigerant levels, electrical connections, and overall operational performance. Addressed customer concerns regarding dehumidifier performance and humidity control issues, including investigation of dehumidifier interaction with AC system cycling. Inspected condenser coils for debris accumulation and verified proper airflow through outdoor unit despite vegetation growth around base. Evaluated indoor equipment including furnace/air handler unit, checked condensate drain lines, and verified proper operation of all system components. System confirmed operational and functioning properly at time of service completion.
Completed installation of dehumidifier system in attic space, including routing and securing of condensate drain line and flexible ductwork through existing insulation and framing. All components properly installed, insulated piping secured to structural members, and system tested for proper operation.
Responded to a fully backed-up kitchen drain with no drainage in a nine-year-old residence. Accessed the plumbing system through the rear of the property and inspected the drain line configuration, including the white PVC drainage piping running through the ceiling joists and structural framing. Successfully cleared the blockage in the kitchen sink drain line, restoring full drainage functionality to the black double-basin sink. Tested water flow through the faucet to verify proper drainage and confirm the system was operating correctly with no standing water or slow drainage issues remaining.
Responded to service call for 3-year-old Trane air conditioning unit that was not producing cold air and subsequently shut down. Rescheduled appointment to morning time slot to accommodate proper diagnostic and repair work. Upon arrival, inspected outdoor condensing unit and refrigerant line connections, noting R22/R410A compatible system with 70 piston configuration at evaporator coil entry point.
Performed leak test on outdoor A/C condensing unit using refrigerant gauges and testing equipment. Connected manifold gauge set with charging hoses to service ports and pressurized system to identify any refrigerant leaks in the condenser coil, line set connections, and service valves.
Performed comprehensive cleaning and inspection of residential air conditioning system. Verified all electrical connections, control components, and refrigerant lines were secure and functioning properly. System tested and confirmed operational, with customer enrolled in preventative maintenance agreement for ongoing service coverage.
Performed site assessment for automatic water shut-off valve installation. Inspected existing plumbing infrastructure beneath kitchen sink area, documenting current water supply line configuration with pressure regulator and copper piping connections. Evaluated mechanical room layout and main water line access points to determine optimal placement for automated shut-off valve system. Photographed existing plumbing setup including supply lines, pressure regulation equipment, and available installation space. Provided customer with detailed estimate for automatic shut-off valve installation based on current plumbing configuration and accessibility requirements.
Responded to service call for air conditioning unit not cooling properly. Upon inspection, found evaporator coil and drain pan with significant dust and debris accumulation affecting system performance. Cleaned evaporator coil, refrigerant lines, and drain pan, removed obstructions, and verified proper airflow restoration. System tested and confirmed cooling operation returned to normal parameters.
Responded to no cooling complaint at commercial office building. Accessed rooftop condenser unit and removed protective grille to inspect internal components. Found condenser coils heavily soiled with debris accumulation restricting airflow. Cleaned condenser coils, inspected refrigerant lines showing normal oxidation, and verified fan motor operation. Accessed interior mechanical cabinet and inspected refrigerant piping connections, ductwork, and associated components for leaks or damage. All connections secure with no refrigerant leaks detected. Reassembled equipment, restored power, and confirmed unit operating properly with adequate cooling to occupied space.
Responded to no-cooling call with indoor temperature at 83 degrees. Performed diagnostic evaluation on 10+ year old HVAC system located in utility closet. Identified system failure preventing proper cooling operation, completed necessary repairs to restore air conditioning function and return home to comfortable temperature.