Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH between October 2026 and November 2026. The most recent job was on November 2, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Installed three customer-supplied portable dehumidifiers in the basement utility area, positioning each unit on the concrete slab near the utility sink and floor drain for gravity drainage access. Verified power connections and unit operation, with the control display confirming proper startup, and left operating instructions with the equipment for the customer's reference.
Performed annual maintenance on a 5-year-old natural gas furnace, including a combustion analysis that verified safe, efficient operation. Flue gas readings recorded at 93.5% efficiency, 6 ppm CO, 5.6% COâ‚‚, 11.0% Oâ‚‚, and 102°F stack temperature, all within acceptable ranges.
Responded to a no-heat complaint on a 40-year-old natural gas furnace with the thermostat unable to raise the temperature above 68 degrees, and inspected the system's operation. Performed a combustion analysis with a Testo 310 analyzer, which measured 5.4% Oâ‚‚ and 2 ppm CO in the flue gases, confirming complete combustion and safe emissions within normal limits.
Performed fall heating maintenance and conducted a combustion analysis on the natural gas furnace at steady-state operation using an electronic combustion analyzer. Readings were within normal operating parameters: O2 7.9%, CO2 7.3%, CO 9 ppm, stack temperature 128°F, and steady-state efficiency of 88.9%, confirming clean combustion and proper heat exchanger performance.
Responded to a call for a damaged thermostat with severed low-voltage wiring. Repaired the cut conductors, restored thermostat connections, and verified proper system operation. Performed a combustion analysis with a Testo 310 analyzer, recording Oâ‚‚ at 10.1% and CO at 4 ppm, which confirmed safe, normal operating levels.
Performed annual heating system maintenance and combustion efficiency analysis. Conducted flue gas testing with a Testo 310 combustion analyzer, which recorded 7.3% Oâ‚‚ and 8 ppm CO, indicating safe, properly operating combustion within acceptable parameters.
Performed annual heating maintenance on a 10-year-old natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable range at 6.13% O2, 27 ppm CO, and 8.28% CO2, indicating proper combustion with no hazardous carbon monoxide levels detected.
Performed seasonal heating maintenance on a gas furnace of unknown age, including inspection of the combustion system and operational checks. Conducted flue gas combustion analysis with a Testo 310 analyzer, recording 7.2% Oâ‚‚ and 2 ppm CO, indicating clean, efficient combustion within safe operating limits. Unit is operating normally with no issues identified.
Performed seasonal heating maintenance on a 5-year-old furnace, including inspection of key components and a combustion analysis using a Testo 310 analyzer. Flue gas readings recorded 8.0% Oâ‚‚ and 8 ppm CO, confirming safe carbon monoxide levels and proper combustion operation.
Performed annual heating maintenance on a 7-year-old natural gas furnace, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a Bacharach analyzer, which showed 91.6% efficiency, 17 ppm CO, 10.9% Oâ‚‚, 5.6% COâ‚‚, and a stack temperature of 108°F, confirming safe and efficient operation within normal parameters.
Performed an on-site evaluation of an existing gas-fired furnace in the basement mechanical area for replacement and retrofit. The inspection covered the removed front access panel, blower motor and housing, gas control valve and wiring, burner assembly, galvanized flue connection, and existing supply ductwork, noting dust accumulation, surface discoloration, and rust staining on the cabinet. Photo-documented the equipment condition, flue and duct configuration, and surrounding components to support sizing and installation planning for the replacement unit.
Responded to a no-heat call on the furnace, diagnosed and corrected the fault preventing heat production, and restored the unit to normal operation. Performed a post-repair combustion analysis with a calibrated analyzer, confirming safe and efficient operation with Oâ‚‚ at 6.1% and CO at 7 ppm, within acceptable limits.
Performed scheduled heating maintenance on a gas-fired furnace, including a combustion analysis of the flue gases with a Testo 310 analyzer. Readings recorded were 8.6% Oâ‚‚ and 20 ppm CO, with CO within acceptable limits and no combustion concerns noted. Unit operated normally upon completion of the maintenance.
Performed a seasonal heating maintenance on a gas-fired furnace, including inspection of the combustion system and verification of safe operation. Conducted flue gas combustion analysis with a Testo 310, recording Oâ‚‚ at 8.7% and CO at 2 ppm, confirming clean combustion and CO levels well within safe limits. The system was left operating normally with no deficiencies noted.
Performed annual maintenance and combustion analysis on two original, basement-installed gas furnaces. Flue gas testing on the first unit showed 79.5% efficiency, 12.1% O2, 6 ppm CO, and 319°F stack temperature, and the second unit showed 76.9% efficiency, 13.0% O2, 7 ppm CO, and 346°F stack temperature. CO levels were within safe limits on both systems, and the efficiency readings are consistent with aging, standard-efficiency equipment.
Performed an on-site evaluation for a furnace retrofit and replacement estimate, inspecting the existing gas furnace, including the blower assembly, wiring, gas valve, and burner section, along with the plenum, galvanized supply ducting, flue venting, and PVC condensate drain with trap. Documented the condition of the system and the outdoor condenser unit, noting its placement, coil guard condition, and surrounding debris and mulch clearance, to determine replacement scope and equipment compatibility.
Performed annual heating maintenance on a 16-year-old gas-fired furnace located in the basement, including a combustion analysis using a Testo 310 analyzer. Flue gas readings were within acceptable limits, with 5.7% COâ‚‚ and CO at 8 ppm, confirming safe and efficient combustion.
Performed seasonal heating maintenance on two Carrier furnaces, including removal of access panels to inspect the draft inducer assembly, wiring harness, and control board. Verified electrical operation with a clamp meter and checked low-voltage connections and condensate drain piping; panels were reinstalled with no damage or abnormalities noted.
Performed annual heating maintenance on a 20-year-old gas-fired furnace located in a second-floor closet. Conducted combustion analysis with a Bacharach analyzer, recording 7.5% Oâ‚‚, 7.5% COâ‚‚, 6 ppm CO, 316°F stack temperature, and 82.2% efficiency, confirming safe, stable combustion within acceptable operating parameters.
Conducted an on-site evaluation of a split-level master bedroom addition currently in the framing and rough-in stage to determine HVAC and plumbing requirements. Assessed the exposed stud walls, OSB subfloor, and open ceiling joists for equipment placement, duct and refrigerant line routing, and plumbing access, noting that existing electrical rough-in and framed openings are in place and the space is clear of damage or obstructions. Verified the layout and conditions to support an accurate replacement estimate for the system serving the new addition.