Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026. The most recent job was on October 14, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Performed scheduled commercial heating maintenance on an Armstrong Air upright gas furnace, inspecting the cabinet, flue and condensate piping, gas line with shutoff valve, and connected supply ductwork. Noted heavy condensation on the galvanized duct surface with a measured surface temperature of 55.8°F, along with peeling foil tape at a duct seam, indicating a need for insulation and seam sealing to prevent moisture accumulation and potential damage. Recommend re-sealing the duct seams and insulating the affected ductwork.
Performed annual heating maintenance on a 10-year-old basement furnace, including inspection of the combustion system and a flue gas analysis with a Bacharach combustion analyzer. Readings on natural gas showed O2 at 7.5%, CO at 92 ppm, CO2 at 7.6%, and combustion efficiency of 79.6%, which were documented for the equipment record.
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer. Readings were within normal operating range at O2 6.5%, CO2 8.1%, CO 12 ppm, and steady-state efficiency of 82.3%, confirming proper combustion and safe operation of the appliance.
Responded to a no-heat complaint on the main floor of a hydronic heating system, with only the upper level receiving heat. Inspected the boiler, circulator, motorized zone valves, and associated control wiring and piping in the mechanical closet, noting surface corrosion and dust accumulation on the boiler cabinet. Evaluated zone valve and control operation to isolate the cause of the lost main-floor heat call, and documented system conditions with photos for further recommendations.
Performed a complete furnace tune-up, including cleaning and inspecting the inducer blower assembly, pressure switches, gas valve, flue connections, and associated wiring, with no visible damage, rust, or abnormalities noted. Conducted a combustion analysis on the flue gases, recording 8.9% O2, 2 ppm CO, and 3 ppm CO-AF with 65.8% excess air, confirming safe and proper operation. Furnace is operating within normal parameters, and the customer was enrolled in the maintenance agreement with a copy provided.
Removed the existing garage furnace and installed a new replacement unit, with associated ductwork modifications to tie the supply and return into the existing distribution system. Cut access openings in the garage wall drywall and disturbed the R-19 fiberglass batt insulation to route and secure the duct and furnace connections. Left the wall cavities open for insulation repair and drywall patching by the finishing trades.
Completed A/C and coil retrofit installation on a residential split system charged with R-454B refrigerant. Verified system performance with a digital manifold gauge set, recording 116.7 psig suction pressure, 283.3 psig discharge pressure, 20.3°F superheat, and 6.5°F subcooling, with saturation temperatures of 43.9°F vapor and 95.0°F liquid. Confirmed charge and operating readings are within acceptable range for system operation.
Performed fall heating maintenance, including a combustion analysis on the natural gas furnace using a calibrated flue gas analyzer. Readings showed O2 at 7.08%, CO2 at 7.75%, and CO at 11 ppm, confirming clean combustion and safe operation within acceptable limits.
Performed seasonal heating maintenance on an 11-year-old natural gas furnace, removing the upper access panel to inspect the burner compartment, gas valve assembly, wiring harness, and blower motor. Conducted flue gas combustion analysis, recording 6.2% O2, 26 ppm CO, and 37 ppm CO air-free at 37.5% excess air, confirming combustion within acceptable parameters. Noted dust accumulation and light corrosion on the cabinet floor of the interior compartment, which should be monitored at future visits.
Completed furnace retrofit installation in mechanical room. Removed existing heating unit and installed new gray metal furnace with proper ductwork connections to existing HVAC system. Ensured all supply and return air ducts were properly sealed and secured to new unit. Verified clearances around equipment meet manufacturer specifications and local code requirements. Tested system operation and confirmed proper airflow throughout distribution system.
Completed fall heating maintenance on Rinnai unit. Performed combustion analysis using Testo 310 analyzer, recording oxygen levels at 9.0-9.3% and carbon monoxide readings at 1-28 ppm. Documented model and serial numbers of existing equipment and identified two additional units requiring future service integration.
# Furnace Maintenance Completed
Performed comprehensive preventive maintenance on a 30-year-old gas furnace system. Accessed internal components by removing front service panel to inspect blower motor assembly, inducer motor, and electrical connections. Verified proper operation of all mechanical components including blower wheel and motor mountings. Inspected wiring throughout unit, noting red, white, and black conductor connections to control board and safety devices.
Examined air filtration system, noting significant dust accumulation on mesh filter screen. Cleaned or replaced filter media as needed to restore proper airflow. Checked filter retention mechanism and housing integrity. Inspected copper refrigerant or gas lines at unit base, including connections and shut-off valve. Verified flexible conduit connections remained secure.
Tested all electrical connections and control circuits for proper voltage and continuity. Confirmed blower motor operation and assessed overall syst
Completed fall maintenance on heating system. Performed combustion analysis using gas analyzer, recording oxygen levels at 9.62%, carbon monoxide at 11 ppm, and carbon dioxide at 6.34%, all within acceptable operating parameters. System tested and confirmed operating safely and efficiently.
Completed installation of a Trane 17.5-ton rooftop unit on a commercial building with proper mounting, electrical disconnect, and weatherproofing. The RTU was secured to the roof structure with support pads and mounting brackets, with all penetrations sealed appropriately. Unit was positioned, leveled, and verified operational with all safety labels and specifications clearly visible on the equipment.
Completed annual heating maintenance on 17-year-old furnace located in basement. Performed combustion analysis using Testo 327-1 analyzer, confirming proper operation with natural gas readings of 7.3% CO2 and 9 ppm CO, indicating efficient and safe combustion within manufacturer specifications.
Completed fall maintenance on heating system. Performed combustion analysis using digital gas detector, verifying proper operation with readings showing oxygen at 88%, carbon monoxide at 18 ppm, and carbon dioxide at 6.8%. All safety checks and seasonal maintenance procedures completed per manufacturer specifications.
Completed furnace retrofit installation in basement mechanical room. Installed new furnace unit with PVC intake and exhaust venting system, connected to existing ductwork infrastructure, and integrated air filtration component to ensure proper system operation and code compliance.
Completed full HVAC system replacement including new air handler unit and outdoor condensing unit. Installed new refrigerant lines, suction line accumulator, and all necessary copper piping with proper insulation and brass fittings. System was mounted, connected, tested, and verified operational with all components functioning to manufacturer specifications.
Completed full HVAC system installation featuring an 80% efficiency downflow furnace with new refrigerant lineset. Installed dual outdoor condensing units on concrete pads with proper electrical disconnects and positioned new indoor air handling equipment in utility area with appropriate drainage and ventilation connections.
Completed comprehensive fall maintenance on residential gas furnace system installed in utility closet. Performed thorough inspection of all major components including heat exchanger, blower assembly, electrical connections, and circulating pump. Cleaned and tested burner assembly, verified proper operation of all safety controls, and confirmed adequate airflow through system. Inspected condensate drain line for proper drainage, checked gas connections for leaks, and verified electrical panel connections were secure with no signs of overheating. System tested and operating within manufacturer specifications for heating season.