Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026. The most recent job was on October 21, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Performed fall heating maintenance on the natural gas furnace, including a flue gas combustion analysis showing 6.9% O2, 43.8% excess air, and 11 ppm CO (16 ppm air-free), all within acceptable operating limits. Inspected and serviced the return air filter, which showed moderate dust loading, to maintain proper airflow and system efficiency. Unit operation verified with no visible rust, frost, or damage observed.
Responded to a no-heat call on a Comfort-Aire gas furnace reported to have a buzzing noise and failure to cycle, with a suspected blower motor or control board fault. Inspected the inducer assembly, pressure switch, gas valve, and burner compartment, then restored operation with stable burner flame established. Verified performance with a combustion analysis on natural gas, recording 5.6% O2, 32.5% excess air, 27 ppm CO, and 37 ppm air-free CO, all within acceptable limits.
Responded to a no-cool call on a 16-year-old gas furnace and performed a combustion analysis on the flue gas using a Testo 327-1 analyzer. Readings showed 6.0% O2, 35.8% excess air, 7 ppm CO, and 10 ppm air-free CO, all within acceptable operating limits for natural gas combustion.
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable range, with O2 at 8.2%, CO2 at 7.1%, CO at 9 ppm, and steady-state efficiency of 88.1%. System operating normally at completion of service.
Performed scheduled heating maintenance on a gas-fired furnace, including inspection of the unit and verification of proper operation. Conducted a combustion analysis using a digital analyzer on natural gas, recording O2 at 7.32%, CO at 7 ppm, and CO2 at 7.62%, with CO levels well within safe limits and indicating clean, stable combustion. No deficiencies were noted and the system was left operating normally.
Performed a descale service on the power-vented Rheem tank water heater, flushing mineral and sediment buildup from the tank and discharging the flush water to the adjacent floor drain. Following the service, the unit, venting, and electrical connections were inspected, and no leaks, corrosion, or visible damage were found.
Installed shutoff valves on the gas piping serving a multi-meter manifold in the basement utility area, connecting flexible gas lines with brass fittings and red-handled isolation valves to each meter. Verified secure connections and proper valve operation at each meter location, with piping routed overhead to the meter bank.
Performed a scheduled commercial heating maintenance visit, inspecting the return air ductwork and verifying the 16x25x1 filter installation, which was found to be dated 10/19/21 and in need of replacement. Measured duct surface temperature at 126.3°F with a digital pocket thermometer to confirm heating operation, and checked the foil-taped duct seams, with no damage, frost, or rust observed.
Performed seasonal fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer to verify safe and efficient operation. Flue gas readings were within acceptable parameters, with O2 at 10.5%, CO at 14 ppm, CO2 at 5.9%, and steady-state efficiency of 96.8%, confirming proper combustion and heat exchanger performance.
Performed seasonal heating maintenance on a 22-year-old basement-installed natural gas furnace. Completed a flue gas combustion analysis with a Testo 327-1, recording 9.2% O2, 69.7% excess air, 2 ppm CO, and 4 ppm air-free CO, all within safe operating limits and confirming proper combustion performance. The unit is operating normally, and the customer is due for maintenance plan renewal.
Completed new construction installation of two HVAC systems, including fabrication and installation of sheet-metal trunk and branch ductwork in the basement and a furnace build-up with supply plenum, insulated flexible duct connections, and a whole-house humidifier with condensate drain piping. All PVC drain and venting lines were routed and secured along the joists and walls, and the equipment was set and connected with no visible deficiencies.
Performed scheduled preventive maintenance on a Reznor suspended unit heater serving the warehouse space, including visual inspection of the unit, piping, wiring, and mounting, with no damage or anomalies observed. Verified heater operation using a digital pocket thermometer, recording a 113.4°F reading at the equipment panel. Noted moisture and runoff residue near the condensate drain connection, indicating condensate discharge during operation.
Performed annual heating maintenance on a natural gas furnace of unknown age, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis with a calibrated flue gas analyzer, recording O2 at 8.21%, CO at 4 ppm, CO2 at 7.13%, and combustion efficiency of 88.5%, confirming safe operation with CO well within acceptable limits and the system operating within normal parameters.
Performed seasonal heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a gas analyzer that recorded O2 at 7.03%, CO at 12 ppm, and CO2 at 7.79%, confirming safe operation within acceptable parameters. Replaced the filtration components with one 213 media filter and one #35 water panel, and verified proper system operation upon completion.
Relocated the condenser lineset and associated electrical to the new unit position on the exterior wall. Rerouted the insulated refrigerant lines and flexible whip from the outdoor disconnect to the condenser, secured them to the siding, and verified all connections are properly supported and weather-protected.
Performed routine annual maintenance and tune-up on the gas furnace, which was operating properly upon arrival. Completed a combustion analysis using a flue gas analyzer, recording O2 at 8.82%, CO at 19 ppm, and CO2 at 6.79% on natural gas, with CO levels within acceptable limits. The system was left operating normally with no repairs required.
Performed scheduled contract maintenance on an Armstrong Air upflow furnace, replacing the 16x25x5 media air filter and labeling it with the installation date for future service tracking. Inspected the filter cabinet, vent connections, condensate piping, and surrounding equipment, noting dust accumulation in the filter rack and surface rust on adjacent piping for monitoring at future visits.
Performed annual preventive maintenance on a 16-year-old natural gas furnace, including a combustion analysis with a calibrated Bacharach analyzer. Final readings were within acceptable parameters: CO at 15 ppm, Oâ‚‚ at 9.4%, COâ‚‚ at 6.5%, and steady-state efficiency of 97.3%, confirming safe and proper combustion.
Installed a new 80% AFUE upflow gas furnace in the basement mechanical area, connecting supply and return plenums and transitions with foil-taped seams. Routed the flue through a flexible chimney liner to the existing exhaust duct, and reconnected the gas supply and electrical controls, leaving the system ready for operation.
Replaced the existing furnace with a new 70K BTU, 96% AFUE, upflow/horizontal gas furnace (ML196UH070XE48B). Fabricated and installed supply and return plenum transitions, connected gas piping with a new gas valve and flexible gas connector, and installed PVC venting and condensate drain components. Installed a new filter, CO/smoke combination detector, and magnetic filter cover, then cleaned up the work area and tested the system for proper operation.