Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH between June 2026 and July 2026. The most recent job was on July 1, 2026.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Responded to service call for excessive condensate discharge in counter room area. Upon inspection, discovered condensate drain line with significant buildup and blockage causing water overflow. Cleared obstruction from drain line, removed accumulated debris and residue from pipe interior, and verified proper drainage flow was restored to prevent further water damage.
Responded to commercial no cooling call. Upon arrival, inspected outdoor condenser unit and took diagnostic measurements of system components. Documented equipment condition and operational parameters to determine cause of cooling failure and provide repair recommendations.
# HVAC Service Report
Responded to commercial air conditioning service call for unit not operating properly. Upon arrival, conducted system inspection and diagnostics. Unable to locate relevant HVAC equipment in provided documentation. Photos received appear to show plumbing fixtures rather than air conditioning components. Requested clarification from customer regarding actual equipment location and specific cooling system concerns to proceed with proper AC unit evaluation and repair.
Completed full HVAC system retrofit including furnace and air conditioning replacement. Removed existing equipment and installed new heating and cooling units in basement utility room. All electrical connections, ductwork transitions, and system controls were properly configured and tested to ensure optimal operation.
Completed AC retrofit installation in residential basement utility room. Installed new Lennox furnace unit with proper metallic ductwork configuration and electrical connections via conduit. Positioned equipment alongside existing water heater on concrete floor with appropriate clearances for service access. Configured supply plenum and flexible duct connections to integrate with existing ventilation system. All components installed per manufacturer specifications with proper labeling visible for future reference.
Responded to callback on 3-year-old Trane commercial A/C unit (Model VSCPG09SEHB2D) that was not cooling adequately, with indoor temperature stuck at 73°F. Performed diagnostic assessment and measured supply air temperature at 53.3°F, indicating potential issues with system capacity or airflow. Customer advised that complete system evaluation is required to identify root cause and repairs will be quoted accordingly.
Completed warranty replacement of gas control valve on Bradford White water heater. Removed defective gas control valve assembly, installed new OEM replacement unit, performed leak test on all gas connections, and verified proper burner operation and temperature settings. Unit tested and returned to normal operation with all safety controls functioning correctly.
Completed full AC retrofit installation including outdoor condensing unit and indoor evaporator coil. Installed new beige cylindrical air conditioning unit on composite pad adjacent to building exterior with proper clearances maintained. Unit features horizontal ventilation slats and top-mounted fan grille for optimal airflow. Connected indoor evaporator coil to existing furnace system in basement mechanical room, integrating with current HVAC infrastructure. Verified proper refrigerant lines, electrical connections, and condensate drainage. System tested and operational, providing efficient cooling capacity for residential structure.
Responded to service call for Mitsubishi Hyper Heat mini split system with two zones experiencing intermittent operation in main 20x20 room while bedroom zone functioned properly. Documented equipment model numbers for both zones: main room unit MS2-FS18NA (serial 10354637T) and bedroom unit MS2-FS09NA (serial 1023106T). Assessed system performance and identified issue with main zone air handler cycling on and off unexpectedly while bedroom zone maintained consistent operation.
Completed full HVAC system retrofit in basement mechanical room, installing new Lennox furnace with complete ductwork modifications. Installed new refrigerant line set and connected all supply and return ductwork to existing distribution system. System tested and operational.
Completed installation of large-diameter white PVC drainage piping system in commercial space beneath elevated structure, routing pipes across exposed concrete ceiling with proper securing brackets and support straps. Installed parallel gray metallic piping runs and coordinated routing with existing fluorescent lighting fixtures and structural elements to ensure proper clearance and code compliance.
Responded to service call for air conditioning system installed 9 months prior that was struggling to maintain temperature during hot weather. Performed diagnostic testing using digital temperature probes to measure supply air temperatures at register and return air temperatures to assess system performance and cooling capacity. Based on temperature differential readings of 85°F, identified inadequate cooling output indicating potential issues with refrigerant charge, airflow restriction, or system sizing relative to cooling load demands.
Completed routine maintenance on 2-year-old Trane XTi residential air conditioning system. Performed standard cooling season inspection including temperature verification at 73°F, examined outdoor condenser unit condition, and confirmed proper system operation. Unit found in good working order with no deficiencies noted.
Completed spring maintenance on residential cooling system. Performed comprehensive inspection of outdoor condenser unit, verified electrical connections at disconnect box, and recorded system readings with meter displaying 1251 (likely voltage or pressure measurement). Unit operating within normal parameters with no immediate service needs identified.
Completed comprehensive HVAC estimate for AC retrofit installation in residential basement mechanical room. Assessed existing furnace and air handling equipment, evaluated ductwork configuration including gray return air ducts and overhead galvanized steel components, and documented current PVC condensate drainage system with white piping running to floor drain. Photographed existing multi-unit HVAC setup, noting wall-mounted control panel, thermostat placement, and exposed ceiling joist structure to determine optimal retrofit approach for new air conditioning system integration with current heating infrastructure.
Responded to no cooling call on 20-year-old air conditioning system. Upon arrival, performed diagnostic evaluation of outdoor condensing unit and indoor air handler system. Inspected electrical connections, refrigerant levels, and overall system operation to identify cause of cooling failure on aging equipment.
Performed filter replacement on commercial rooftop package HVAC unit. Customer-supplied 16x20 pleated air filter was installed in the unit housing, with filter properly seated and access panel secured upon completion.
Responded to no cooling complaint in front area with afternoon cooling issues in back unit. Upon inspection, discovered severe heat damage and deterioration to ductwork components, with extensive charring and oxidation along panel seams and joints. Temperature reading of 87.4°F confirmed inadequate cooling performance. Inspected Trane RTU and found compromised air filter requiring replacement. Replaced allergen filter and assessed heat-damaged ductwork sections for necessary repairs to restore proper system operation and airflow distribution.
Responded to no cool call on 10-month-old mini split system requiring manual resets to operate. Performed diagnostic evaluation of indoor air handler and reviewed system operation. Upon inspection, determined the intermittent operation issue was unrelated to the recent installation and advised customer of chargeable service nature. Accessed indoor unit for thorough examination of electrical connections, control board functionality, and filter condition to identify root cause of manual reset requirement.
Responded to callback for AC system not cooling properly with persistent knocking noise. Upon arrival, inspected HVAC system including air handler unit, ductwork, and associated piping in mechanical room. Identified and addressed mechanical issue causing abnormal operational sounds. Verified condensate drain lines and PVC piping connections for proper function. Tested system operation and confirmed resolution of knocking noise and restored normal cooling performance.