Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026. The most recent job was on October 5, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Completed routine heating maintenance and tune-up on Lennox furnace system. System was operating properly upon arrival with no reported issues. Performed comprehensive inspection of furnace components, verified proper airflow and temperature readings using digital instrumentation, checked venting system integrity including PVC intake and exhaust pipes, and confirmed all safety controls and labels were in place. System left in proper working condition.
Completed comprehensive tune-up service on both air conditioning and furnace systems. Performed thorough cleaning and inspection of all components, verified proper operation of Aprilaire Media Air Cleaner Model 2200, checked ductwork connections, and confirmed system functionality. All equipment found to be operating within normal parameters with no immediate service needs identified.
# HVAC Fall Maintenance Service
Completed comprehensive fall maintenance inspection on residential HVAC system. Discovered severe frost and ice accumulation on indoor air handling unit and evaporator coil assembly, indicating critical system malfunction. The indoor unit exhibited extensive ice buildup on access panels, refrigerant lines, and ductwork, with icicle formation suggesting prolonged freezing condition likely caused by restricted airflow, low refrigerant charge, or faulty defrost controls.
Documented conditions with photographs showing crystalline frost patterns covering metal panels and insulated refrigerant lines. The ice accumulation on the cylindrical duct and throughout the system indicated the unit had been operating in a compromised state, potentially causing reduced heating efficiency and possible compressor damage if left unaddressed.
Inspected outdoor heat pump unit positioned on concrete pad against exterior wall. Unit appeared in normal physical condition with
Completed fall heating maintenance on natural gas furnace. Performed combustion analysis using digital gas analyzer, confirming system operating within safe parameters with oxygen levels at 8.70%, carbon monoxide at 17 ppm, and carbon dioxide at 6.85%.
Completed furnace retrofit installation in mechanical room, replacing existing HVAC unit with new system including proper venting configuration using white PVC piping routed through overhead ductwork. Installation included integration with existing humidification system (blue and white component), connection to galvanized metal ductwork and flexible ducting, proper electrical wiring and conduit placement, and verification of all system components for optimal operation in the basement utility space.
Completed comprehensive fall maintenance tune-up on 11-year-old furnace system with no reported operational issues. Performed standard seasonal inspection including temperature readings, verified proper system operation, and inspected all mechanical components as part of preventative maintenance program. Unit operating within normal parameters with no deficiencies noted.
Completed fall preventative maintenance on residential gas furnace system. Performed comprehensive inspection of all major components including blower assembly, pressure switch, gas valve, burner rack, and associated wiring and controls. All components found operating within normal parameters with no immediate safety concerns or required repairs identified at this time.
Completed scheduled commercial filter maintenance visit on rooftop HVAC equipment. Inspected and serviced York package unit and Mitsubishi Electric condensing unit (Model PUT-A24NHA7, R410A refrigerant), verified proper operation of all systems, and documented equipment conditions through photographic records for maintenance tracking purposes.
Completed comprehensive tune-up and maintenance on a 6-7 year old natural gas furnace. Performed combustion analysis using calibrated gas analyzer, measuring oxygen levels, carbon monoxide output, combustion efficiency, and carbon dioxide levels. Initial readings showed Oâ‚‚ at 15.8%, CO at 32 ppm, efficiency at 75.8%, and COâ‚‚ at 8.9%. Made necessary adjustments to optimize burner performance, resulting in improved final readings of Oâ‚‚ at 13.2%, CO reduced to 7 ppm, efficiency increased to 77.9%, and COâ‚‚ at 4.3%. All measurements now within acceptable operating parameters for safe and efficient furnace operation.
Completed full HVAC system retrofit including installation of new Lennox furnace in basement mechanical room and matching Lennox air conditioning unit on exterior gravel pad. Connected all ductwork, electrical service, and refrigerant lines between indoor and outdoor components, ensuring proper system operation and compliance with manufacturer specifications.
Completed scheduled heating maintenance on natural gas furnace. Performed combustion analysis using diagnostic equipment, confirming system operating within acceptable parameters with oxygen levels at 8.0%, carbon monoxide at 33 ppm, efficiency at 80.0%, and carbon dioxide at 9.3%. Unit found in satisfactory operating condition with no immediate service needs identified.
Completed fall maintenance tune-up on natural gas heating system. Performed combustion analysis using digital gas analyzer, confirming proper system operation with oxygen levels at 8.4%, carbon monoxide at 16 ppm, efficiency at 82.4%, and carbon dioxide at 7.1%. Customer's maintenance agreement requires renewal.
Completed comprehensive furnace maintenance tune-up on 12-year-old heating unit with no reported operational issues. Performed full system inspection including blower motor assembly, electrical connections, gas lines, and internal components. All wiring harnesses, copper refrigerant lines, and control mechanisms inspected and found to be in proper working condition with normal operational wear for unit age.
Completed full HVAC system replacement including furnace and air conditioning condenser unit. Installed new gas furnace in basement utility area with proper venting and ductwork connections, integrated humidifier system, and electrical controls. Replaced outdoor AC condenser unit on concrete pad with appropriate refrigerant line connections, electrical disconnect, and conduit routing along exterior brick wall. All equipment installed to manufacturer specifications with proper clearances, verified system operation, and ensured all safety controls functioning correctly.
Accessed interior wall cavity to diagnose and address non-functioning expansion tank and exterior hose spigot. Cut access opening through drywall to expose plumbing lines and structural framing. Identified copper piping running horizontally through wall cavity requiring repair or replacement. Protected work area with drop cloth during wall penetration and diagnostic procedures. Exposed internal plumbing infrastructure to facilitate necessary repairs to restore proper function to both the expansion tank system and outdoor water supply.
Performed routine tune-up and inspection on six-year-old furnace system located in basement. Removed front access panel and conducted comprehensive examination of all internal components including Honeywell gas valve, gas piping connections, electrical wiring, and control systems. Verified proper operation of all safety features and mechanical components. Inspected burner assembly, heat exchanger, blower motor, and electronic controls for signs of wear or deterioration. Tested electrical connections and verified proper voltage throughout system. Examined venting system including PVC intake and exhaust pipes for proper installation and clearances. Checked condensate drainage system for blockages. Inspected all wiring connections for tightness and proper insulation. Verified gas line connections and tested for leaks at valve and piping joints. System found to be operating within normal parameters with no issues detected. All components functioning properly with appropriate airflow and co
Completed rough-in and installation of ductwork system for commercial new construction project. Installed metal air handling unit panels, secured all connections with appropriate fasteners, and ran distribution ductwork throughout the space. Installed registers and thermostats per specifications to ensure proper air distribution and climate control functionality for the facility.
Responded to commercial no cooling call where rooftop HVAC units were running continuously and not responding to thermostat commands. Performed diagnostic testing on outdoor condensing unit using multimeter to measure electrical parameters and verify proper system operation. Identified and resolved thermostat communication issue, restoring normal cycling operation to equipment.
Completed full HVAC system replacement including indoor air handler and outdoor condensing unit. Installed new equipment in basement utility area with proper ductwork connections and electrical wiring, including refrigerant line sets with insulation. Positioned outdoor condenser unit on existing concrete pad, cleared surrounding vegetation for proper airflow and accessibility. System tested and operational upon completion.
Completed fall maintenance on Goodman furnace model AUD100R83BX13 manufactured in November 2004. Performed combustion analysis using Bacharach analyzer, which confirmed system operating within acceptable parameters with oxygen reading at 7.1%, carbon monoxide at 3 ppm, efficiency at 80.3%, and carbon dioxide at 7.8%. All measurements indicate proper combustion and safe operation for the heating season.