Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in June 2026.

The most recent job was on June 26, 2026.

Job Locations and Reviews

Completed spring maintenance on commercial rooftop HVAC unit. Performed comprehensive system inspection including electrical connections, capacitor evaluation, and ductwork assessment. Documented equipment conditions with rooftop measurements and component photography showing normal operational wear on piping and connections.
Completed spring maintenance on commercial rooftop HVAC unit. Performed comprehensive system inspection including electrical connections, capacitor evaluation, and ductwork assessment. Documented equipment conditions with rooftop measurements and component photography showing normal operational wear on piping and connections.
Jamir W.
Jamir W. Checked in
Completed spring maintenance on commercial rooftop HVAC unit. Performed comprehensive system inspection including electrical connections, capacitor evaluation, and ductwork assessment. Documented equipment conditions with rooftop measurements and component photography showing normal operational wear on piping and connections.
Akron, OH 44312
# HVAC Service Call - No Airflow from Two Registers

Responded to service call regarding lack of airflow from two registers in the home. Upon arrival, conducted visual inspection of the HVAC distribution system in the basement/crawlspace area to identify the source of the airflow issue.

Performed thorough examination of the ductwork routing and connections serving the affected registers. Inspected the main trunk lines and branch ducts for potential obstructions, disconnections, or damage that could restrict airflow. Evaluated the condition of flexible ductwork runs, noting dust accumulation and age-related wear on black flexible ducting visible in the ceiling cavity.

Assessed the structural support and mounting of ductwork components, checking metal strapping and brackets securing ducts to floor joists. Verified that insulated supply lines were properly installed and not compressed or kinked, which could impede air distribution to specific zones.

Traced ductwork pathways through the
# HVAC Service Call - No Airflow from Two Registers

Responded to service call regarding lack of airflow from two registers in the home. Upon arrival, conducted visual inspection of the HVAC distribution system in the basement/crawlspace area to identify the source of the airflow issue.

Performed thorough examination of the ductwork routing and connections serving the affected registers. Inspected the main trunk lines and branch ducts for potential obstructions, disconnections, or damage that could restrict airflow. Evaluated the condition of flexible ductwork runs, noting dust accumulation and age-related wear on black flexible ducting visible in the ceiling cavity.

Assessed the structural support and mounting of ductwork components, checking metal strapping and brackets securing ducts to floor joists. Verified that insulated supply lines were properly installed and not compressed or kinked, which could impede air distribution to specific zones.

Traced ductwork pathways through the
Nick D.
Nick D. Checked in
# HVAC Service Call - No Airflow from Two Registers Responded to service call regarding lack of airflow from two registers in the home. Upon arrival, conducted visual inspection of the HVAC distribution system in the basement/crawlspace area to identify the source of the airflow issue. Performed thorough examination of the ductwork routing and connections serving the affected registers. Inspected the main trunk lines and branch ducts for potential obstructions, disconnections, or damage that could restrict airflow. Evaluated the condition of flexible ductwork runs, noting dust accumulation and age-related wear on black flexible ducting visible in the ceiling cavity. Assessed the structural support and mounting of ductwork components, checking metal strapping and brackets securing ducts to floor joists. Verified that insulated supply lines were properly installed and not compressed or kinked, which could impede air distribution to specific zones. Traced ductwork pathways through the
Akron, OH 44320
Completed comprehensive plumbing inspection of residential property to assess condition of existing plumbing infrastructure throughout the home. Examined exposed piping in basement/crawl space areas including supply lines and drainage systems, and inspected under-sink plumbing connections including P-trap assemblies and PVC drain lines. Customer enrolled in maintenance plan and requested detailed estimate for whole-house plumbing upgrades based on inspection findings.
Completed comprehensive plumbing inspection of residential property to assess condition of existing plumbing infrastructure throughout the home. Examined exposed piping in basement/crawl space areas including supply lines and drainage systems, and inspected under-sink plumbing connections including P-trap assemblies and PVC drain lines. Customer enrolled in maintenance plan and requested detailed estimate for whole-house plumbing upgrades based on inspection findings.
Jeremy B.
Jeremy B. Checked in
Completed comprehensive plumbing inspection of residential property to assess condition of existing plumbing infrastructure throughout the home. Examined exposed piping in basement/crawl space areas including supply lines and drainage systems, and inspected under-sink plumbing connections including P-trap assemblies and PVC drain lines. Customer enrolled in maintenance plan and requested detailed estimate for whole-house plumbing upgrades based on inspection findings.
Akron, OH 44314
Completed spring maintenance on residential cooling system. Installed new Filtrete 1550 air filter (16x25x4) in HVAC system, noting significant deterioration and rust on metal filter housing that will require monitoring. Inspected outdoor Emerson condenser unit and observed excessive vegetation growth around base restricting airflow. Cleared grass and weeds from perimeter of unit to restore proper ventilation and prevent potential efficiency loss or compressor damage. Condenser housing showed weathering consistent with age but unit operational. Recommended ongoing vegetation management around outdoor unit and future assessment of corroded filter compartment housing for potential replacement to prevent air quality issues and maintain system integrity.
Completed spring maintenance on residential cooling system. Installed new Filtrete 1550 air filter (16x25x4) in HVAC system, noting significant deterioration and rust on metal filter housing that will require monitoring. Inspected outdoor Emerson condenser unit and observed excessive vegetation growth around base restricting airflow. Cleared grass and weeds from perimeter of unit to restore proper ventilation and prevent potential efficiency loss or compressor damage. Condenser housing showed weathering consistent with age but unit operational. Recommended ongoing vegetation management around outdoor unit and future assessment of corroded filter compartment housing for potential replacement to prevent air quality issues and maintain system integrity.
Roderick H.
Roderick H. Checked in
Completed spring maintenance on residential cooling system. Installed new Filtrete 1550 air filter (16x25x4) in HVAC system, noting significant deterioration and rust on metal filter housing that will require monitoring. Inspected outdoor Emerson condenser unit and observed excessive vegetation growth around base restricting airflow. Cleared grass and weeds from perimeter of unit to restore proper ventilation and prevent potential efficiency loss or compressor damage. Condenser housing showed weathering consistent with age but unit operational. Recommended ongoing vegetation management around outdoor unit and future assessment of corroded filter compartment housing for potential replacement to prevent air quality issues and maintain system integrity.
Akron, OH 44314
Akron, OH - Completed spring maintenance on residential cooling system. Performed comprehensive inspection of outdoor condensing unit, including electrical compartment evaluation where contactor, capacitor, and Comfort Alert module were examined and found to be in proper working condition. All electrical connections were verified secure, and unit was confirmed operational for the cooling season.
Zack W.
Zack W. Checked in
Completed spring maintenance on residential cooling system. Performed comprehensive inspection of outdoor condensing unit, including electrical compartment evaluation where contactor, capacitor, and Comfort Alert module were examined and found to be in proper working condition. All electrical connections were verified secure, and unit was confirmed operational for the cooling season.
Akron, OH 44312
Completed preventive maintenance tune-up on both furnace and air conditioning system. Performed combustion analysis on natural gas furnace showing acceptable readings with 92.7% efficiency, 15 ppm CO, 12.4% O2, and 4.8% CO2. Serviced Allied Air Enterprises 4SCU13LE13GP-6 outdoor condensing unit utilizing HFC-410A refrigerant, confirmed unit specifications and proper operation.
Completed preventive maintenance tune-up on both furnace and air conditioning system. Performed combustion analysis on natural gas furnace showing acceptable readings with 92.7% efficiency, 15 ppm CO, 12.4% O2, and 4.8% CO2. Serviced Allied Air Enterprises 4SCU13LE13GP-6 outdoor condensing unit utilizing HFC-410A refrigerant, confirmed unit specifications and proper operation.
Maddex H.
Maddex H. Checked in
Completed preventive maintenance tune-up on both furnace and air conditioning system. Performed combustion analysis on natural gas furnace showing acceptable readings with 92.7% efficiency, 15 ppm CO, 12.4% O2, and 4.8% CO2. Serviced Allied Air Enterprises 4SCU13LE13GP-6 outdoor condensing unit utilizing HFC-410A refrigerant, confirmed unit specifications and proper operation.
Akron, OH 44321
Provided quote for replacement of 13-year-old natural gas tanked water heater showing visible rust deterioration at base unit. Assessed existing equipment condition and discussed replacement options with property owner for scheduling installation after 12pm.
Provided quote for replacement of 13-year-old natural gas tanked water heater showing visible rust deterioration at base unit. Assessed existing equipment condition and discussed replacement options with property owner for scheduling installation after 12pm.
Jeremy B.
Jeremy B. Checked in
Provided quote for replacement of 13-year-old natural gas tanked water heater showing visible rust deterioration at base unit. Assessed existing equipment condition and discussed replacement options with property owner for scheduling installation after 12pm.
Akron, OH 44312
Completed full HVAC system retrofit in attic space, including removal of existing equipment and installation of new furnace and air conditioning system. Installed new supply and return ductwork with proper insulation, routed refrigerant lines with foam insulation sleeves, and secured all components to structural framing per manufacturer specifications. System was tested for proper airflow, refrigerant charge, and operational performance, with all installations meeting code requirements.
Completed full HVAC system retrofit in attic space, including removal of existing equipment and installation of new furnace and air conditioning system. Installed new supply and return ductwork with proper insulation, routed refrigerant lines with foam insulation sleeves, and secured all components to structural framing per manufacturer specifications. System was tested for proper airflow, refrigerant charge, and operational performance, with all installations meeting code requirements.
Blake C.
Blake C. Checked in
Completed full HVAC system retrofit in attic space, including removal of existing equipment and installation of new furnace and air conditioning system. Installed new supply and return ductwork with proper insulation, routed refrigerant lines with foam insulation sleeves, and secured all components to structural framing per manufacturer specifications. System was tested for proper airflow, refrigerant charge, and operational performance, with all installations meeting code requirements.
Akron, OH 44333
Completed spring maintenance on commercial HVAC unit. Performed comprehensive system inspection including electrical testing with clamp meter, verifying voltage and amperage readings within normal operating parameters. Inspected condenser coil fins and blower assembly, confirming proper operation and airflow. All components functioning as designed with no deficiencies noted. Unit operational and ready for cooling season.
Completed spring maintenance on commercial HVAC unit. Performed comprehensive system inspection including electrical testing with clamp meter, verifying voltage and amperage readings within normal operating parameters. Inspected condenser coil fins and blower assembly, confirming proper operation and airflow. All components functioning as designed with no deficiencies noted. Unit operational and ready for cooling season.
Jamir W.
Jamir W. Checked in
Completed spring maintenance on commercial HVAC unit. Performed comprehensive system inspection including electrical testing with clamp meter, verifying voltage and amperage readings within normal operating parameters. Inspected condenser coil fins and blower assembly, confirming proper operation and airflow. All components functioning as designed with no deficiencies noted. Unit operational and ready for cooling season.
Akron, OH 44319
Completed spring maintenance inspection on cooling system. During the routine service, identified and documented significant corrosion and thread deterioration on critical mounting bolts and fasteners, which will require monitoring or replacement to prevent potential equipment failure. All standard maintenance procedures were performed according to manufacturer specifications.
Completed spring maintenance inspection on cooling system. During the routine service, identified and documented significant corrosion and thread deterioration on critical mounting bolts and fasteners, which will require monitoring or replacement to prevent potential equipment failure. All standard maintenance procedures were performed according to manufacturer specifications.
Maddex H.
Maddex H. Checked in
Completed spring maintenance inspection on cooling system. During the routine service, identified and documented significant corrosion and thread deterioration on critical mounting bolts and fasteners, which will require monitoring or replacement to prevent potential equipment failure. All standard maintenance procedures were performed according to manufacturer specifications.
Akron, OH 44312
Completed replacement of failed condenser fan motor and blade assembly on rooftop unit #1, restoring proper airflow and operational capacity. Additionally, replaced defective air proven switch on rooftop unit #3 to ensure proper safety interlock function and system operation. Both units tested and verified operational upon completion of repairs.
Completed replacement of failed condenser fan motor and blade assembly on rooftop unit #1, restoring proper airflow and operational capacity. Additionally, replaced defective air proven switch on rooftop unit #3 to ensure proper safety interlock function and system operation. Both units tested and verified operational upon completion of repairs.
Deepak R.
Deepak R. Checked in
Completed replacement of failed condenser fan motor and blade assembly on rooftop unit #1, restoring proper airflow and operational capacity. Additionally, replaced defective air proven switch on rooftop unit #3 to ensure proper safety interlock function and system operation. Both units tested and verified operational upon completion of repairs.
Akron, OH 44312
Completed full HVAC system retrofit including removal of existing equipment and installation of new Carrier air conditioning unit on exterior concrete pad with proper leveling and gravel base. Installed new furnace in basement utility area with updated metal ductwork routing and silver insulated ducting connections. Mounted electrical disconnect box on exterior wall and ran refrigerant lines and electrical conduit from outdoor condenser unit through wall penetration to indoor equipment. Verified all connections, tested system operation, and ensured proper airflow through ventilation louvers.
Completed full HVAC system retrofit including removal of existing equipment and installation of new Carrier air conditioning unit on exterior concrete pad with proper leveling and gravel base. Installed new furnace in basement utility area with updated metal ductwork routing and silver insulated ducting connections. Mounted electrical disconnect box on exterior wall and ran refrigerant lines and electrical conduit from outdoor condenser unit through wall penetration to indoor equipment. Verified all connections, tested system operation, and ensured proper airflow through ventilation louvers.
Nate R.
Nate R. Checked in
Completed full HVAC system retrofit including removal of existing equipment and installation of new Carrier air conditioning unit on exterior concrete pad with proper leveling and gravel base. Installed new furnace in basement utility area with updated metal ductwork routing and silver insulated ducting connections. Mounted electrical disconnect box on exterior wall and ran refrigerant lines and electrical conduit from outdoor condenser unit through wall penetration to indoor equipment. Verified all connections, tested system operation, and ensured proper airflow through ventilation louvers.
Akron, OH 44314
Akron, OH - Completed scheduled maintenance on four residential air conditioning units, all six years old. Performed comprehensive inspections including visual assessment of compressor components, electrical connections, and condensate pans. All units showed normal wear consistent with age, with minor surface corrosion and debris accumulation noted in condensate drain pans. Verified proper operation of all systems upon completion.
Tom M.
Tom M. Checked in
Completed scheduled maintenance on four residential air conditioning units, all six years old. Performed comprehensive inspections including visual assessment of compressor components, electrical connections, and condensate pans. All units showed normal wear consistent with age, with minor surface corrosion and debris accumulation noted in condensate drain pans. Verified proper operation of all systems upon completion.
Akron, OH 44333
# Commercial A/C Service Call

Responded to service call for non-operational commercial air conditioning unit. Upon arrival, performed comprehensive system inspection and discovered severely compromised condenser coil with extensive dirt, dust, and debris accumulation throughout the aluminum fin assembly. The heavy contamination was restricting airflow and preventing proper heat exchange, resulting in system failure.

Documented pre-service condition showing thick grayish-brown buildup embedded throughout the finned surfaces, with particularly dense accumulation in multiple areas. The condenser coil exhibited signs of extended operation without routine maintenance, including bent fins and environmental debris lodged between fin spacing. This contamination was significantly reducing the unit's cooling capacity and efficiency.

Performed thorough condenser coil cleaning using appropriate chemical cleaners and pressure washing techniques to remove all accumulated dirt and debris from the
# Commercial A/C Service Call

Responded to service call for non-operational commercial air conditioning unit. Upon arrival, performed comprehensive system inspection and discovered severely compromised condenser coil with extensive dirt, dust, and debris accumulation throughout the aluminum fin assembly. The heavy contamination was restricting airflow and preventing proper heat exchange, resulting in system failure.

Documented pre-service condition showing thick grayish-brown buildup embedded throughout the finned surfaces, with particularly dense accumulation in multiple areas. The condenser coil exhibited signs of extended operation without routine maintenance, including bent fins and environmental debris lodged between fin spacing. This contamination was significantly reducing the unit's cooling capacity and efficiency.

Performed thorough condenser coil cleaning using appropriate chemical cleaners and pressure washing techniques to remove all accumulated dirt and debris from the
Jamir W.
Jamir W. Checked in
# Commercial A/C Service Call Responded to service call for non-operational commercial air conditioning unit. Upon arrival, performed comprehensive system inspection and discovered severely compromised condenser coil with extensive dirt, dust, and debris accumulation throughout the aluminum fin assembly. The heavy contamination was restricting airflow and preventing proper heat exchange, resulting in system failure. Documented pre-service condition showing thick grayish-brown buildup embedded throughout the finned surfaces, with particularly dense accumulation in multiple areas. The condenser coil exhibited signs of extended operation without routine maintenance, including bent fins and environmental debris lodged between fin spacing. This contamination was significantly reducing the unit's cooling capacity and efficiency. Performed thorough condenser coil cleaning using appropriate chemical cleaners and pressure washing techniques to remove all accumulated dirt and debris from the
Akron, OH 44311
Completed comprehensive preventive maintenance on a 4-year-old residential air conditioning system. Performed full system inspection of outdoor condenser unit, including visual assessment of cabinet condition, fan assembly, and motor components. Cleaned condenser coils to remove environmental buildup and debris accumulation from fins. Verified proper operation of condenser fan motor and checked fan blade integrity and protective grille security. Inspected refrigerant line connections and condensate drain system, noting white PVC discharge line in proper working condition. Checked unit mounting and leveling on concrete pad. Cleared vegetation and debris from around unit perimeter to ensure adequate airflow and prevent future obstruction. System operating within normal parameters with no deficiencies noted. Unit maintained proper clearances and showed appropriate wear for age. All components functioning as designed with no immediate service needs identified.
Completed comprehensive preventive maintenance on a 4-year-old residential air conditioning system. Performed full system inspection of outdoor condenser unit, including visual assessment of cabinet condition, fan assembly, and motor components. Cleaned condenser coils to remove environmental buildup and debris accumulation from fins. Verified proper operation of condenser fan motor and checked fan blade integrity and protective grille security. Inspected refrigerant line connections and condensate drain system, noting white PVC discharge line in proper working condition. Checked unit mounting and leveling on concrete pad. Cleared vegetation and debris from around unit perimeter to ensure adequate airflow and prevent future obstruction. System operating within normal parameters with no deficiencies noted. Unit maintained proper clearances and showed appropriate wear for age. All components functioning as designed with no immediate service needs identified.
Roderick H.
Roderick H. Checked in
Completed comprehensive preventive maintenance on a 4-year-old residential air conditioning system. Performed full system inspection of outdoor condenser unit, including visual assessment of cabinet condition, fan assembly, and motor components. Cleaned condenser coils to remove environmental buildup and debris accumulation from fins. Verified proper operation of condenser fan motor and checked fan blade integrity and protective grille security. Inspected refrigerant line connections and condensate drain system, noting white PVC discharge line in proper working condition. Checked unit mounting and leveling on concrete pad. Cleared vegetation and debris from around unit perimeter to ensure adequate airflow and prevent future obstruction. System operating within normal parameters with no deficiencies noted. Unit maintained proper clearances and showed appropriate wear for age. All components functioning as designed with no immediate service needs identified.
Akron, OH 44319
Completed routine air conditioning tune-up and preventative maintenance service. Inspected system components, checked refrigerant levels, and tested operational performance. Evaluated and documented air filter condition, noting accumulation of dust and debris; filter shows signs of normal usage and will require replacement at next service interval to maintain optimal system efficiency and indoor air quality.
Completed routine air conditioning tune-up and preventative maintenance service. Inspected system components, checked refrigerant levels, and tested operational performance. Evaluated and documented air filter condition, noting accumulation of dust and debris; filter shows signs of normal usage and will require replacement at next service interval to maintain optimal system efficiency and indoor air quality.
Deepak R.
Deepak R. Checked in
Completed routine air conditioning tune-up and preventative maintenance service. Inspected system components, checked refrigerant levels, and tested operational performance. Evaluated and documented air filter condition, noting accumulation of dust and debris; filter shows signs of normal usage and will require replacement at next service interval to maintain optimal system efficiency and indoor air quality.
Akron, OH 44319
Completed scheduled maintenance on residential air conditioning system over 10 years old. Performed standard tune-up procedures including inspection of HVAC unit, ductwork, and refrigerant lines in attic space. Identified condensate drain line requiring replacement and documented condition with photos for customer review and future service planning.
Completed scheduled maintenance on residential air conditioning system over 10 years old. Performed standard tune-up procedures including inspection of HVAC unit, ductwork, and refrigerant lines in attic space. Identified condensate drain line requiring replacement and documented condition with photos for customer review and future service planning.
Nick D.
Nick D. Checked in
Completed scheduled maintenance on residential air conditioning system over 10 years old. Performed standard tune-up procedures including inspection of HVAC unit, ductwork, and refrigerant lines in attic space. Identified condensate drain line requiring replacement and documented condition with photos for customer review and future service planning.
Akron, OH 44333
Completed AC retrofit installation in basement mechanical room. Installed new dark gray furnace unit with white PVC venting system for proper exhaust and intake air management. Positioned equipment on concrete floor alongside existing HVAC components including air handler unit. Configured all necessary piping connections, electrical conduit, and safety labeling per manufacturer specifications and code requirements. System tested and verified operational.
Completed AC retrofit installation in basement mechanical room. Installed new dark gray furnace unit with white PVC venting system for proper exhaust and intake air management. Positioned equipment on concrete floor alongside existing HVAC components including air handler unit. Configured all necessary piping connections, electrical conduit, and safety labeling per manufacturer specifications and code requirements. System tested and verified operational.
Nate R.
Nate R. Checked in
Completed AC retrofit installation in basement mechanical room. Installed new dark gray furnace unit with white PVC venting system for proper exhaust and intake air management. Positioned equipment on concrete floor alongside existing HVAC components including air handler unit. Configured all necessary piping connections, electrical conduit, and safety labeling per manufacturer specifications and code requirements. System tested and verified operational.
Akron, OH 44312
Responded to service call for non-functional front panel on residential Desert Air air conditioning unit located in basement utility area. Upon arrival, inspected unit and diagnosed control panel malfunction. Tested electrical connections, verified power supply to panel, and determined front display interface required replacement. Replaced faulty control panel assembly, restored proper system operation, and verified all functions operating normally. Unit tested successfully with proper cooling cycle initiation and temperature control response.
Responded to service call for non-functional front panel on residential Desert Air air conditioning unit located in basement utility area. Upon arrival, inspected unit and diagnosed control panel malfunction. Tested electrical connections, verified power supply to panel, and determined front display interface required replacement. Replaced faulty control panel assembly, restored proper system operation, and verified all functions operating normally. Unit tested successfully with proper cooling cycle initiation and temperature control response.
Zack W.
Zack W. Checked in
Responded to service call for non-functional front panel on residential Desert Air air conditioning unit located in basement utility area. Upon arrival, inspected unit and diagnosed control panel malfunction. Tested electrical connections, verified power supply to panel, and determined front display interface required replacement. Replaced faulty control panel assembly, restored proper system operation, and verified all functions operating normally. Unit tested successfully with proper cooling cycle initiation and temperature control response.
Akron, OH 44313
Completed furnace retrofit in basement mechanical room, installing new Lennox high-efficiency gas furnace with associated white PVC venting system routed vertically through ceiling. Integrated unit with existing ductwork infrastructure, including large-diameter supply plenum and 16x25 return air configuration. All electrical connections, condensate drainage, and combustion air venting installed per manufacturer specifications and local code requirements.
Completed furnace retrofit in basement mechanical room, installing new Lennox high-efficiency gas furnace with associated white PVC venting system routed vertically through ceiling. Integrated unit with existing ductwork infrastructure, including large-diameter supply plenum and 16x25 return air configuration. All electrical connections, condensate drainage, and combustion air venting installed per manufacturer specifications and local code requirements.
Blake C.
Blake C. Checked in
Completed furnace retrofit in basement mechanical room, installing new Lennox high-efficiency gas furnace with associated white PVC venting system routed vertically through ceiling. Integrated unit with existing ductwork infrastructure, including large-diameter supply plenum and 16x25 return air configuration. All electrical connections, condensate drainage, and combustion air venting installed per manufacturer specifications and local code requirements.
Akron, OH 44685

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.