Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH between May 2026 and June 2026. The most recent job was on June 3, 2026.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
# A/C Replacement
Completed full air conditioning system replacement including new outdoor condensing unit and indoor evaporator coil. Installed new A-frame coil matched to furnace configuration in existing indoor mechanical closet. Mounted new condensing unit at exterior location and completed refrigerant line set connections using R-454B refrigerant. Performed system evacuation and charged unit to manufacturer specifications. Verified proper system operation with digital manifold gauge readings showing 121.4 psig low side pressure and 241.9 psig high side pressure. Confirmed superheat at 7.8°F and subcooling at 10.6°F, both within acceptable operating range and meeting target specifications of 10°F and 11°F respectively. System temperatures stabilized with low temp at 53.8°F and high temp at 73.6°F, indicating proper refrigerant flow and heat exchange. All electrical connections completed to code, condensate drain line installed and tested for proper drainage. System startup success
Replumbed backyard spigot connection to main water supply line in basement crawl space. Installed new black supply pipe with shutoff valve and hose connection, securing all components to cinder block foundation wall per code requirements.
Completed scheduled commercial cooling maintenance visit on rooftop HVAC unit. Inspected multi-filter air filtration assembly and noted moderate dust and debris accumulation across pleated filters with varying levels of loading. Accessed electrical control panel and verified wiring connections, contactors, and safety disconnect functionality. All electrical components operating within normal parameters with warning labels intact and visible.
Provided comprehensive estimate for complete HVAC system replacement involving existing York furnace and air conditioning equipment located in basement utility area. Assessed current installation including ductwork configuration, condensate drainage system, gas piping, and electrical connections to determine scope of replacement work and equipment specifications needed for proper system sizing and installation.
Performed preventive maintenance on 20+ year old air conditioning system. Inspected outdoor condensing unit located in below-grade corrugated metal enclosure, removed accumulated leaves and organic debris from concrete pad and unit perimeter, and checked refrigerant line insulation condition. Evaluated indoor ductwork system with reflective insulation wrapping and verified proper mechanical connections throughout the installation.
Responded to customer report of natural gas odor originating from furnace/AC utility room following recent AC maintenance. Performed thorough safety inspection of the mechanical room, including gas leak detection procedures and examination of all gas-fired equipment connections. Inspected furnace, water heater, and associated gas piping for potential leaks or compromised fittings. Documented existing plumbing and HVAC infrastructure conditions via photographs for service records. All gas connections tested and verified secure with no active leaks detected at time of inspection.
Completed full HVAC system retrofit including new air handler and air conditioning condenser unit. Installed outdoor condensing unit on prepared pad with proper clearances from structure, ran new electrical conduit and disconnect box, and established refrigerant line connections between outdoor unit and air handler. All components properly mounted, leveled, and secured with electrical connections completed to code specifications.
Completed full HVAC system retrofit installation including new furnace and air conditioning unit. Interior installation features new gray metal furnace with integrated humidifier system, PVC venting, insulated flexible ductwork, and proper electrical connections with conduit routing. Exterior installation includes new residential condenser unit with electrical disconnect boxes and conduit properly mounted to brick wall. All components installed to manufacturer specifications with appropriate drainage, venting, and electrical connections verified operational.
Completed spring maintenance on outdoor cooling system. Performed electrical diagnostics using multimeter, recording voltage readings at capacitor and verifying proper electrical parameters throughout the system. Inspected condenser unit exterior, coils, and fan assembly for operational condition and typical seasonal wear.
Conducted comprehensive assessment of existing HVAC system including outdoor air conditioning condenser unit and indoor gas furnace for replacement estimate. Evaluated current equipment condition, measured existing unit specifications, documented installation locations, and photographed both exterior condenser positioned on concrete pad near building perimeter and interior furnace system with ductwork configuration in basement utility area. Provided customer with replacement options and system sizing recommendations based on home requirements.
Completed comprehensive AC tune-up on 20-year-old air conditioning system. Inspected outdoor condenser unit, noting weathering and minor algae growth on casing and base pad. Verified proper airflow direction on 20x25x5 air filter assembly within ductwork, documented filter replacement date, and confirmed thermostat control operation. System operational and functioning within normal parameters for unit age.
Completed air conditioning retrofit installation in residential utility space. Existing Lennox Elite furnace system assessed and integrated with new A/C components, including refrigerant line connections, condensate drainage via PVC piping, and electrical controls. All mechanical connections secured and system tested for proper operation with existing HVAC infrastructure.
Completed preventative maintenance inspection on 20-year-old air conditioning system with 2-4 window configuration under maintenance agreement. Inspected ductwork system in attic space, verifying proper connections at plenum transitions and ensuring all flexible and rigid duct sections remain secure and sealed. Examined electrical components including capacitor, noting age-related surface corrosion on housing while verifying proper electrical specifications and functionality for continued operation.
Completed routine cooling system maintenance on a five-year-old air conditioning system. Performed comprehensive tune-up including inspection of the outdoor condenser unit and indoor air handler, verified refrigerant levels, checked electrical connections, cleaned condenser coils, and tested system operation. All components found to be functioning properly with no issues identified during the maintenance visit.
Replaced two duct smoke detectors within the HVAC air handler unit and installed new keyed test stations on the wall for manual system testing. All devices were properly wired, tested for functionality, and verified operational upon completion.
Completed comprehensive spring maintenance on Lennox outdoor condensing unit and associated HVAC system components. Performed standard seasonal inspection protocol including visual assessment of condensing unit exterior condition, electrical disconnect box, refrigerant line connections, and proper unit leveling on concrete pad. Verified outdoor unit operational status with no visible damage or significant wear noted to housing, louvers, or fan grille assembly. Inspected Aprilaire 600 Series humidifier mounted to ductwork in mechanical room, confirming proper installation and electrical connections. Documented equipment condition through photographic record showing both exterior condensing unit and interior humidification system components in functional operating condition. All system components assessed and found operating within normal parameters for seasonal startup.
# HVAC New Construction Install
Completed installation of radiant heating system on new construction concrete foundation slab. Installed multiple parallel runs of red PEX tubing in serpentine loop configuration across entire slab surface. Tubing secured and positioned systematically with proper spacing for optimal heat distribution. Junction boxes placed at strategic intervals along tubing runs for system connectivity and control. Installation performed on prepared concrete foundation with anchor bolts in place, ready for next phase of construction. System layout designed for efficient radiant floor heating operation in new residential structure.
Completed spring maintenance on two-year-old cooling system. Performed standard preventive maintenance procedures including inspection of refrigerant lines, condensate drain system, and ductwork connections. All components inspected and found operating within normal parameters. System tested and confirmed operational.
Completed scheduled commercial filter maintenance on Payne furnace system. Accessed furnace cabinet, inspected blower motor assembly and internal components, and replaced air filters in white metal air handler unit. Verified all mechanical components operating within normal parameters, checked condensate drain lines and PVC venting for proper function, and confirmed ductwork connections secure. System restored to full operation with improved airflow efficiency.
Completed preventative maintenance service on 12-year-old Goodman 4SCU13LE136P-5 air conditioning unit utilizing R410A refrigerant. Performed standard system inspection, documented equipment model and serial number 1614B07900, verified nameplate specifications, and confirmed unit operational status. All components functioning within normal parameters at time of service completion.