Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in February 2026.

The most recent job was on February 10, 2026.

Job Locations and Reviews

Responded to emergency service call for 6-year-old furnace exhibiting water damage. Upon inspection, found significant rust formation at bottom of furnace compartment, indicating prolonged moisture exposure. Completed necessary repairs to address water infiltration issue and restore proper operation.
Responded to emergency service call for 6-year-old furnace exhibiting water damage. Upon inspection, found significant rust formation at bottom of furnace compartment, indicating prolonged moisture exposure. Completed necessary repairs to address water infiltration issue and restore proper operation.
Zack W.
Zack W. Checked in
Responded to emergency service call for 6-year-old furnace exhibiting water damage. Upon inspection, found significant rust formation at bottom of furnace compartment, indicating prolonged moisture exposure. Completed necessary repairs to address water infiltration issue and restore proper operation.
Akron, OH 44312
Performed diagnostic assessment of non-functioning heating system. Recommended complete replacement of existing furnace and A/C unit due to failure. Conducted site evaluation in utility room where current furnace is installed adjacent to water heater and laundry equipment. Documented existing ductwork configuration and available space for new system installation.
Performed diagnostic assessment of non-functioning heating system. Recommended complete replacement of existing furnace and A/C unit due to failure. Conducted site evaluation in utility room where current furnace is installed adjacent to water heater and laundry equipment. Documented existing ductwork configuration and available space for new system installation.
Brad M.
Brad M. Checked in
Performed diagnostic assessment of non-functioning heating system. Recommended complete replacement of existing furnace and A/C unit due to failure. Conducted site evaluation in utility room where current furnace is installed adjacent to water heater and laundry equipment. Documented existing ductwork configuration and available space for new system installation.
Akron, OH 44306
Akron, OH - Responded to service call for furnace displaying alert code 7276 (repeat occurrence since November service). Performed combustion analysis using Bacharach analyzer which indicated optimal performance parameters (Oâ‚‚: 6.9%, CO: 22ppm, COâ‚‚: 7.9%, efficiency: 98.9%). System is functioning within manufacturer specifications with no immediate concerns identified.
Nick D.
Nick D. Checked in
Responded to service call for furnace displaying alert code 7276 (repeat occurrence since November service). Performed combustion analysis using Bacharach analyzer which indicated optimal performance parameters (Oâ‚‚: 6.9%, CO: 22ppm, COâ‚‚: 7.9%, efficiency: 98.9%). System is functioning within manufacturer specifications with no immediate concerns identified.
Akron, OH 44319
Akron, OH - Completed routine furnace maintenance service on natural gas heating system. Performed combustion analysis using Bacharach analyzer, confirming system is operating within acceptable parameters (82.9% efficiency, 10ppm CO, 7.2% CO2, 289°F stack temperature).
Joshua L.
Joshua L. Checked in
Completed routine furnace maintenance service on natural gas heating system. Performed combustion analysis using Bacharach analyzer, confirming system is operating within acceptable parameters (82.9% efficiency, 10ppm CO, 7.2% CO2, 289°F stack temperature).
Akron, OH 44319
Responded to client request for shower plumbing service regarding water drainage issue. Inspected white bathtub and shower assembly with chrome fixtures showing signs of age and mineral deposits. Resolved drainage problem that was causing water to hold in tub, restoring proper water flow and functionality.
Responded to client request for shower plumbing service regarding water drainage issue. Inspected white bathtub and shower assembly with chrome fixtures showing signs of age and mineral deposits. Resolved drainage problem that was causing water to hold in tub, restoring proper water flow and functionality.
Jeremy B.
Jeremy B. Checked in
Responded to client request for shower plumbing service regarding water drainage issue. Inspected white bathtub and shower assembly with chrome fixtures showing signs of age and mineral deposits. Resolved drainage problem that was causing water to hold in tub, restoring proper water flow and functionality.
Akron, OH 44319
Akron, OH - Responded to no heat call for 20+ year old furnace. Upon inspection, identified worn mounting bracket and compromised fasteners in the assembly. Secured loose components and restored proper operation of the heating system.
Tom M.
Tom M. Checked in
Responded to no heat call for 20+ year old furnace. Upon inspection, identified worn mounting bracket and compromised fasteners in the assembly. Secured loose components and restored proper operation of the heating system.
Akron, OH 44313
Akron, OH - Responded to no-heat service call. Conducted combustion analysis using Sauermann analyzer which revealed optimal gas furnace performance with 89.3% efficiency and minimal CO levels (11 ppm). System is operating within manufacturer specifications after service.
Jake T.
Jake T. Checked in
Responded to no-heat service call. Conducted combustion analysis using Sauermann analyzer which revealed optimal gas furnace performance with 89.3% efficiency and minimal CO levels (11 ppm). System is operating within manufacturer specifications after service.
Akron, OH 44302
Akron, OH - Completed retrofit installation of a new furnace with integrated humidifier and air cleaner system in customer's utility room. Properly connected all required ductwork with metallic tape seals and ensured proper insulation around the installation area. System was thoroughly tested and is now functioning correctly, resolving the previous "No Heat" condition.
Blake C.
Blake C. Checked in
Completed retrofit installation of a new furnace with integrated humidifier and air cleaner system in customer's utility room. Properly connected all required ductwork with metallic tape seals and ensured proper insulation around the installation area. System was thoroughly tested and is now functioning correctly, resolving the previous "No Heat" condition.
Akron, OH 44313
Akron, OH - Diagnosed heating system blowing cold air in 3-year-old furnace. Performed combustion analysis using Testo 327-1 analyzer, which revealed 8.5% Oâ‚‚, 40 PPM CO, and 67 PPM CO-AF with 63.7% excess air. Adjusted air-fuel ratio to restore proper heating function and verified unit is still under manufacturer warranty.
Zack W.
Zack W. Checked in
Diagnosed heating system blowing cold air in 3-year-old furnace. Performed combustion analysis using Testo 327-1 analyzer, which revealed 8.5% Oâ‚‚, 40 PPM CO, and 67 PPM CO-AF with 63.7% excess air. Adjusted air-fuel ratio to restore proper heating function and verified unit is still under manufacturer warranty.
Akron, OH 44319
Akron, OH - Performed follow-up service call after previous technician's visit. Conducted complete combustion analysis using Bacharach analyzer, which confirmed optimal system performance with 98.9% efficiency, CO levels at 19ppm, Oâ‚‚ at 9.2%, and COâ‚‚ at 6.6%. System is now operating within manufacturer specifications.
Nick D.
Nick D. Checked in
Performed follow-up service call after previous technician's visit. Conducted complete combustion analysis using Bacharach analyzer, which confirmed optimal system performance with 98.9% efficiency, CO levels at 19ppm, Oâ‚‚ at 9.2%, and COâ‚‚ at 6.6%. System is now operating within manufacturer specifications.
Akron, OH 44319
Performed routine maintenance on a 4-year-old furnace. Conducted combustion analysis using Bacharach INSIGHT gas analyzer, which revealed stack temperature of 357°F, Oâ‚‚ at 10.8%, COâ‚‚ at 5.7%, and system efficiency of 79.0%. CO readings were at acceptable levels (18 ppm). Unit is functioning within normal parameters.
Performed routine maintenance on a 4-year-old furnace. Conducted combustion analysis using Bacharach INSIGHT gas analyzer, which revealed stack temperature of 357°F, Oâ‚‚ at 10.8%, COâ‚‚ at 5.7%, and system efficiency of 79.0%. CO readings were at acceptable levels (18 ppm). Unit is functioning within normal parameters.
Tom M.
Tom M. Checked in
Performed routine maintenance on a 4-year-old furnace. Conducted combustion analysis using Bacharach INSIGHT gas analyzer, which revealed stack temperature of 357°F, Oâ‚‚ at 10.8%, COâ‚‚ at 5.7%, and system efficiency of 79.0%. CO readings were at acceptable levels (18 ppm). Unit is functioning within normal parameters.
Akron, OH 44313
Performed scheduled furnace maintenance service. Conducted combustion analysis using Bacharach gas analyzer, confirming proper operation with readings showing 88.6% efficiency, CO at 5-9 ppm, and COâ‚‚ at 5.3%. System is operating within safe parameters with good air/fuel mixture (143.0% excess air).
Performed scheduled furnace maintenance service. Conducted combustion analysis using Bacharach gas analyzer, confirming proper operation with readings showing 88.6% efficiency, CO at 5-9 ppm, and COâ‚‚ at 5.3%. System is operating within safe parameters with good air/fuel mixture (143.0% excess air).
Tom M.
Tom M. Checked in
Performed scheduled furnace maintenance service. Conducted combustion analysis using Bacharach gas analyzer, confirming proper operation with readings showing 88.6% efficiency, CO at 5-9 ppm, and COâ‚‚ at 5.3%. System is operating within safe parameters with good air/fuel mixture (143.0% excess air).
Akron, OH 44319
Akron, OH - Completed installation of Heil furnace unit in residential basement with proper ductwork connections and ventilation system. Installed metallic silver components including diagonal vent pipe connecting to main rectangular duct. Left replacement filters with size information noted on housing for future maintenance.
Brad M.
Brad M. Checked in
Completed installation of Heil furnace unit in residential basement with proper ductwork connections and ventilation system. Installed metallic silver components including diagonal vent pipe connecting to main rectangular duct. Left replacement filters with size information noted on housing for future maintenance.
Akron, OH 44301
Akron, OH - Replaced faulty blower motor pickup on customer's HVAC system. Performed post-repair combustion analysis with Sauermann device, confirming proper system operation with excellent efficiency readings (eta+ 89.6%, eta 98.9%) and safe CO levels (28 ppm).
Jake T.
Jake T. Checked in
Replaced faulty blower motor pickup on customer's HVAC system. Performed post-repair combustion analysis with Sauermann device, confirming proper system operation with excellent efficiency readings (eta+ 89.6%, eta 98.9%) and safe CO levels (28 ppm).
Akron, OH 44306
Akron, OH - Performed diagnostic service on furnace that was cycling without producing heat. Conducted combustion analysis using Sauermann gas analyzer, which revealed O2 at 10.69%, CO at 22 ppm, CO2 at 5.74%, with efficiency readings of 82.8% and 91.3%. Restored proper heating operation after adjustments.
Jake T.
Jake T. Checked in
Performed diagnostic service on furnace that was cycling without producing heat. Conducted combustion analysis using Sauermann gas analyzer, which revealed O2 at 10.69%, CO at 22 ppm, CO2 at 5.74%, with efficiency readings of 82.8% and 91.3%. Restored proper heating operation after adjustments.
Akron, OH 44305
Performed inspection of 45-year-old Conquest 80 furnace system to prepare estimate for replacement. Evaluated existing ductwork configuration, noting inadequate return air and missing bathroom supply. Documented current installation with photos showing outdated plenum design and suboptimal duct routing through floor joists. Customer requires comprehensive quote for new furnace, A/C unit, dehumidifier, and correction of existing ductwork deficiencies.
Performed inspection of 45-year-old Conquest 80 furnace system to prepare estimate for replacement. Evaluated existing ductwork configuration, noting inadequate return air and missing bathroom supply. Documented current installation with photos showing outdated plenum design and suboptimal duct routing through floor joists. Customer requires comprehensive quote for new furnace, A/C unit, dehumidifier, and correction of existing ductwork deficiencies.
Brad M.
Brad M. Checked in
Performed inspection of 45-year-old Conquest 80 furnace system to prepare estimate for replacement. Evaluated existing ductwork configuration, noting inadequate return air and missing bathroom supply. Documented current installation with photos showing outdated plenum design and suboptimal duct routing through floor joists. Customer requires comprehensive quote for new furnace, A/C unit, dehumidifier, and correction of existing ductwork deficiencies.
Akron, OH 44319
Akron, OH - Responded to no heat call for furnace of unknown age. Upon inspection, detected elevated carbon monoxide levels with readings of 47 ppm μCO and 70 ppm CO using gas analyzer. Recommended immediate safety inspection of heat exchanger and combustion process to address potentially dangerous CO production.
Brynn L.
Brynn L. Checked in
Responded to no heat call for furnace of unknown age. Upon inspection, detected elevated carbon monoxide levels with readings of 47 ppm μCO and 70 ppm CO using gas analyzer. Recommended immediate safety inspection of heat exchanger and combustion process to address potentially dangerous CO production.
Akron, OH 44320
Completed installation of a new Lennox HVAC system in basement utility area, including furnace unit with proper sheet metal ductwork connections and PVC venting pipes. System was integrated with existing plumbing infrastructure, with all components properly secured to concrete block walls and ceiling joists for optimal performance.
Completed installation of a new Lennox HVAC system in basement utility area, including furnace unit with proper sheet metal ductwork connections and PVC venting pipes. System was integrated with existing plumbing infrastructure, with all components properly secured to concrete block walls and ceiling joists for optimal performance.
Blake C.
Blake C. Checked in
Completed installation of a new Lennox HVAC system in basement utility area, including furnace unit with proper sheet metal ductwork connections and PVC venting pipes. System was integrated with existing plumbing infrastructure, with all components properly secured to concrete block walls and ceiling joists for optimal performance.
Akron, OH 44312
Akron, OH - Performed routine maintenance on customer's 3-year-old furnace. Conducted combustion analysis showing O2 at 8.29%, CO at 28 ppm, CO2 at 7.08%, with efficiency readings of 79.0% and 87.1%. System is operating within acceptable parameters, though efficiency could be improved. Customer will schedule AC maintenance separately when weather permits.
Jake T.
Jake T. Checked in
Performed routine maintenance on customer's 3-year-old furnace. Conducted combustion analysis showing O2 at 8.29%, CO at 28 ppm, CO2 at 7.08%, with efficiency readings of 79.0% and 87.1%. System is operating within acceptable parameters, though efficiency could be improved. Customer will schedule AC maintenance separately when weather permits.
Akron, OH 44305
Akron, OH - Completed fall maintenance on heating system. Performed combustion analysis using Bacharach Fyrite INSIGHT analyzer, confirming optimal operation with 96.9% efficiency, 8.2% O2, 7.2% CO2, and CO at 26 ppm - all within acceptable parameters for natural gas equipment.
Nick D.
Nick D. Checked in
Completed fall maintenance on heating system. Performed combustion analysis using Bacharach Fyrite INSIGHT analyzer, confirming optimal operation with 96.9% efficiency, 8.2% O2, 7.2% CO2, and CO at 26 ppm - all within acceptable parameters for natural gas equipment.
Akron, OH 44303

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.