Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in February 2026.

The most recent job was on February 5, 2026.

Job Locations and Reviews

Akron, OH - Completed furnace inspection with combustion analysis using Sauermann gas analyzer. System testing showed furnace operating at 88.5% efficiency (eta+) with acceptable CO levels at 31ppm and CO2 at 7.85%. All readings within normal parameters, confirming proper combustion performance.
Jake T.
Jake T. Checked in
Completed furnace inspection with combustion analysis using Sauermann gas analyzer. System testing showed furnace operating at 88.5% efficiency (eta+) with acceptable CO levels at 31ppm and CO2 at 7.85%. All readings within normal parameters, confirming proper combustion performance.
Akron, OH 44321
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Deepak R.
Deepak R. Checked in
Responded to service call for RTU serving back half of building that was blowing cold air. Inspected system and found faulty pressure switch preventing ignition sequence. Also noted blower motor and assembly had significant dust buildup affecting airflow. Replaced pressure switch, cleaned blower wheel and motor components, restoring proper heating function.
Akron, OH 44305
Akron, OH - Diagnosed 30-year-old residential furnace exhibiting short cycling issue. Visual inspection revealed significant corrosion and wear on blower motor assembly with deteriorated wiring connections. Recommended replacement due to age and condition of equipment.
Tom M.
Tom M. Checked in
Diagnosed 30-year-old residential furnace exhibiting short cycling issue. Visual inspection revealed significant corrosion and wear on blower motor assembly with deteriorated wiring connections. Recommended replacement due to age and condition of equipment.
Akron, OH 44313
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Clay B.
Clay B. Checked in
Completed contract maintenance on 4 HVAC units. Performed electrical component inspection, testing capacitor parameters using digital multimeter, and verifying proper electrical connections. All units now operational with measurements within manufacturer specifications.
Akron, OH 44310
Akron, OH - Replaced defective blower motor under warranty (labor only). Performed gas combustion analysis with Sauermann analyzer, verifying proper system operation with readings showing 88.8% efficiency, O2 at 6.60%, CO at 5 ppm, and CO2 at 8.02%.
Jake T.
Jake T. Checked in
Replaced defective blower motor under warranty (labor only). Performed gas combustion analysis with Sauermann analyzer, verifying proper system operation with readings showing 88.8% efficiency, O2 at 6.60%, CO at 5 ppm, and CO2 at 8.02%.
Akron, OH 44312
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Nick D.
Nick D. Checked in
Responded to service call for furnace not heating properly. Performed combustion analysis on Goodman furnace (model G2D95BT100V20C-1) with Bacharach analyzer showing acceptable readings: 90.5% efficiency, 11ppm CO, 4.2% CO2, and 101°F stack temperature. System now operating within normal parameters.
Akron, OH 44333
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Brynn L.
Brynn L. Checked in
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, verifying CO readings between 8-14 ppm, which are within acceptable safety parameters. System is operating properly with no issues detected.
Akron, OH 44314
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Clay B.
Clay B. Checked in
Responded to commercial furnace service call for non-operational system. Inspected and replaced dirty air filter that was restricting airflow. Noted water staining on ceiling tile near air diffuser which may indicate previous condensate leak. System functioning properly after service.
Akron, OH 44312
Akron, OH - Successfully installed a new Lennox furnace unit in the basement utility room, connecting it to the existing ductwork system. Ensured proper ventilation with metal ductwork extending upward and horizontally across the ceiling area, and verified all connections were secure and functioning correctly.
Blake C.
Blake C. Checked in
Successfully installed a new Lennox furnace unit in the basement utility room, connecting it to the existing ductwork system. Ensured proper ventilation with metal ductwork extending upward and horizontally across the ceiling area, and verified all connections were secure and functioning correctly.
Akron, OH 44314
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Deepak R.
Deepak R. Checked in
Responded to service call for non-operational furnace in evidence room. Diagnosed issue with ductless mini-split system. Inspected outdoor condenser unit which showed signs of weathering and was placed directly on snow-covered ground. Restored heating functionality to ensure proper climate control for evidence storage area.
Akron, OH 44319
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Brynn L.
Brynn L. Checked in
Conducted annual heating maintenance on 5-year-old LK system. Performed combustion analysis with Testo 310 analyzer, confirming acceptable readings (Oâ‚‚: 7.9%, CO: 3-6 ppm, COâ‚‚: 3%). System operating within manufacturer specifications with no safety concerns detected.
Akron, OH 44319
Akron, OH - Responded to service call for furnace with startup issues. Performed combustion analysis with digital analyzer, confirming readings of 8 PPM CO, 12 PPM CO-CF, at 489% excess air and 79% efficiency. System now operating correctly after adjustment.
Zack W.
Zack W. Checked in
Responded to service call for furnace with startup issues. Performed combustion analysis with digital analyzer, confirming readings of 8 PPM CO, 12 PPM CO-CF, at 489% excess air and 79% efficiency. System now operating correctly after adjustment.
Akron, OH 44319
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Brad M.
Brad M. Checked in
Completed retrofit installation of a residential HVAC system, replacing the existing equipment with a new Lennox furnace unit and outdoor air conditioning condenser. Multiple quotes were provided to customer before proceeding with the installation, which included proper connection of all ductwork, electrical components, and PVC venting.
Akron, OH 44312
Akron, OH - Performed scheduled heating maintenance service and conducted combustion analysis using Bacharach analyzer. System tested with readings of 8.7% oxygen and 5ppm carbon monoxide, indicating proper combustion within acceptable safety parameters.
Joshua L.
Joshua L. Checked in
Performed scheduled heating maintenance service and conducted combustion analysis using Bacharach analyzer. System tested with readings of 8.7% oxygen and 5ppm carbon monoxide, indicating proper combustion within acceptable safety parameters.
Akron, OH 44333
Akron, OH - Conducted comprehensive evaluation of 6 RTUs as requested. During inspection, documented belt drive system on one unit showing signs of wear with visible dust accumulation and slight corrosion on the pulley mechanism. Visual assessment indicates routine maintenance may be required to address potential belt system deterioration.
Deepak R.
Deepak R. Checked in
Conducted comprehensive evaluation of 6 RTUs as requested. During inspection, documented belt drive system on one unit showing signs of wear with visible dust accumulation and slight corrosion on the pulley mechanism. Visual assessment indicates routine maintenance may be required to address potential belt system deterioration.
Akron, OH 44310
Akron, OH - Performed annual maintenance on 12-year-old furnace. Conducted combustion analysis with Testo 310 gas analyzer, confirming CO levels at 1.5 ppm and 0 ppm, which are within safe operating parameters.
Brynn L.
Brynn L. Checked in
Performed annual maintenance on 12-year-old furnace. Conducted combustion analysis with Testo 310 gas analyzer, confirming CO levels at 1.5 ppm and 0 ppm, which are within safe operating parameters.
Akron, OH 44312
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Brynn L.
Brynn L. Checked in
Performed standard heating maintenance service on residential system. Conducted combustion analysis using Testo 310 gas analyzer, which recorded oxygen (Oâ‚‚) level at 7.5% and carbon monoxide (CO) readings between 26-41 ppm, indicating proper combustion efficiency within acceptable safety parameters.
Akron, OH 44319
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Brynn L.
Brynn L. Checked in
Performed routine furnace maintenance, including combustion analysis with Testo 310 analyzer. Initial readings showed Oâ‚‚ at 10.1% and CO at 0 ppm, with follow-up readings indicating CO levels of 10-19 ppm. All combustion parameters within acceptable ranges, confirming safe and efficient operation of heating system.
Akron, OH 44301
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Brynn L.
Brynn L. Checked in
Performed tune-up on 15-year-old furnace that was cycling on/off. Conducted combustion analysis using Testo 310, which showed acceptable CO readings between 6-7 ppm and Oâ‚‚ levels at 8.4%. System is now operating within normal parameters under existing service agreement.
Akron, OH 44319
Akron, OH - Performed scheduled residential heating maintenance service. Conducted combustion analysis using Bacharach analyzer, confirming system is operating at 96.4% efficiency with acceptable CO levels (11 ppm), proper Oâ‚‚ (7.5%) and COâ‚‚ (7.6%) readings, and normal stack temperature (100°F).
Joshua L.
Joshua L. Checked in
Performed scheduled residential heating maintenance service. Conducted combustion analysis using Bacharach analyzer, confirming system is operating at 96.4% efficiency with acceptable CO levels (11 ppm), proper Oâ‚‚ (7.5%) and COâ‚‚ (7.6%) readings, and normal stack temperature (100°F).
Akron, OH 44303

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.