Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH between January 2026 and February 2026.

The most recent job was on February 2, 2026.

Job Locations and Reviews

Completed scheduled heating maintenance service. Performed combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings at 6.5% and CO levels at 10-19 ppm, which are within acceptable safety parameters. System is functioning efficiently with no issues detected.
Completed scheduled heating maintenance service. Performed combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings at 6.5% and CO levels at 10-19 ppm, which are within acceptable safety parameters. System is functioning efficiently with no issues detected.
Brynn L.
Brynn L. Checked in
Completed scheduled heating maintenance service. Performed combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings at 6.5% and CO levels at 10-19 ppm, which are within acceptable safety parameters. System is functioning efficiently with no issues detected.
Akron, OH 44303
Akron, OH - Performed annual heating maintenance on 8-year-old furnace. Conducted combustion analysis with Bacharach analyzer showing system operating at 82.0% efficiency with acceptable CO levels (5ppm), stack temperature of 322°F, and proper Oâ‚‚/COâ‚‚ readings (8.8%/6.8%). All parameters within normal operating range for natural gas system.
Joshua L.
Joshua L. Checked in
Performed annual heating maintenance on 8-year-old furnace. Conducted combustion analysis with Bacharach analyzer showing system operating at 82.0% efficiency with acceptable CO levels (5ppm), stack temperature of 322°F, and proper Oâ‚‚/COâ‚‚ readings (8.8%/6.8%). All parameters within normal operating range for natural gas system.
Akron, OH 44303
Akron, OH - Responded to no heat call. Diagnosed issue and obtained replacement motor from RSC Akron. Performed combustion analysis after repair with readings of O2 7.6%, CO 46ppm, CO2 7.5%, and efficiency at 82.5%, confirming proper system operation.
Nick D.
Nick D. Checked in
Responded to no heat call. Diagnosed issue and obtained replacement motor from RSC Akron. Performed combustion analysis after repair with readings of O2 7.6%, CO 46ppm, CO2 7.5%, and efficiency at 82.5%, confirming proper system operation.
Akron, OH 44301
Completed furnace replacement in basement utility area due to no-heat condition. Installed new furnace unit with proper connections to existing ductwork system. Ensured proper clearance from water heater and verified all connections were secure and operational before completion.
Completed furnace replacement in basement utility area due to no-heat condition. Installed new furnace unit with proper connections to existing ductwork system. Ensured proper clearance from water heater and verified all connections were secure and operational before completion.
Brad M.
Brad M. Checked in
Completed furnace replacement in basement utility area due to no-heat condition. Installed new furnace unit with proper connections to existing ductwork system. Ensured proper clearance from water heater and verified all connections were secure and operational before completion.
Akron, OH 44314
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, measuring O2 levels at 7.2-7.3% and CO at 6 ppm, confirming proper combustion efficiency and safe operation of heating system.
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, measuring O2 levels at 7.2-7.3% and CO at 6 ppm, confirming proper combustion efficiency and safe operation of heating system.
Brynn L.
Brynn L. Checked in
Performed scheduled furnace maintenance service. Conducted combustion analysis using Testo 310 analyzer, measuring O2 levels at 7.2-7.3% and CO at 6 ppm, confirming proper combustion efficiency and safe operation of heating system.
Akron, OH 44333
Akron, OH - Responded to customer call regarding furnace not heating and making high-pitched screeching noise. Customer had restarted unit prior to arrival. Performed combustion analysis on Amana furnace with Testo 327-1 analyzer, which indicated normal operating parameters (58.8% excess air, 9 ppm CO, 15 ppm CO air-free). Unit was functioning properly during inspection with no screeching noise detected.
Zack W.
Zack W. Checked in
Responded to customer call regarding furnace not heating and making high-pitched screeching noise. Customer had restarted unit prior to arrival. Performed combustion analysis on Amana furnace with Testo 327-1 analyzer, which indicated normal operating parameters (58.8% excess air, 9 ppm CO, 15 ppm CO air-free). Unit was functioning properly during inspection with no screeching noise detected.
Akron, OH 44321
Akron, OH - Performed annual preventative maintenance on natural gas furnace as part of MVP membership. Conducted combustion analysis using Sauermann gas analyzer, confirming system is operating at 88.5% efficiency (eta+) with acceptable oxygen levels at 11.11% and minimal carbon monoxide production (9 ppm). System efficiency parameters are within normal operating range.
Jake T.
Jake T. Checked in
Performed annual preventative maintenance on natural gas furnace as part of MVP membership. Conducted combustion analysis using Sauermann gas analyzer, confirming system is operating at 88.5% efficiency (eta+) with acceptable oxygen levels at 11.11% and minimal carbon monoxide production (9 ppm). System efficiency parameters are within normal operating range.
Akron, OH 44319
Akron, OH - Diagnosed and serviced 10+ year old HVAC system with no cooling issue. Inspection revealed failed condenser fan motor with visible wear and deteriorated wiring connections. Replaced motor, reconnected wiring to manufacturer specifications, and verified proper system operation with acceptable pressure readings on gauge.
Joshua L.
Joshua L. Checked in
Diagnosed and serviced 10+ year old HVAC system with no cooling issue. Inspection revealed failed condenser fan motor with visible wear and deteriorated wiring connections. Replaced motor, reconnected wiring to manufacturer specifications, and verified proper system operation with acceptable pressure readings on gauge.
Akron, OH 44314
Akron, OH - Performed combustion analysis on natural gas furnace using Bacharach analyzer, confirming optimal operation with 98.2% efficiency, acceptable O2 levels at 8.6%, CO at safe 14 ppm, CO2 at 6.9%, and normal stack temperature of 85°F.
Joshua L.
Joshua L. Checked in
Performed combustion analysis on natural gas furnace using Bacharach analyzer, confirming optimal operation with 98.2% efficiency, acceptable O2 levels at 8.6%, CO at safe 14 ppm, CO2 at 6.9%, and normal stack temperature of 85°F.
Akron, OH 44313
Akron, OH - Responded to emergency service call for non-operational furnace of unknown age. Performed combustion analysis using Bacharach gas analyzer, which revealed system operating at 81.0% efficiency with acceptable CO levels (13 ppm). Stack temperature measured at 295°F with 5.3% COâ‚‚ and 11.4% Oâ‚‚, indicating proper combustion parameters.
Joshua L.
Joshua L. Checked in
Responded to emergency service call for non-operational furnace of unknown age. Performed combustion analysis using Bacharach gas analyzer, which revealed system operating at 81.0% efficiency with acceptable CO levels (13 ppm). Stack temperature measured at 295°F with 5.3% COâ‚‚ and 11.4% Oâ‚‚, indicating proper combustion parameters.
Akron, OH 44313
Performed routine tune-up on 15-year-old gas furnace as requested. Conducted combustion analysis using Testo 310 analyzer to verify proper operation and safety parameters. Differential pressure measurements confirmed system is operating within manufacturer specifications.
Performed routine tune-up on 15-year-old gas furnace as requested. Conducted combustion analysis using Testo 310 analyzer to verify proper operation and safety parameters. Differential pressure measurements confirmed system is operating within manufacturer specifications.
Brynn L.
Brynn L. Checked in
Performed routine tune-up on 15-year-old gas furnace as requested. Conducted combustion analysis using Testo 310 analyzer to verify proper operation and safety parameters. Differential pressure measurements confirmed system is operating within manufacturer specifications.
Akron, OH 44319
Completed fall maintenance inspection on commercial HVAC system. Examined Honeywell control device showing signs of aging and weathering with adhesive tape around lower portion. Inspected terminal block connections and verified proper wiring configuration with all leads (green, white, red, yellow, and black) securely connected to appropriate terminals.
Completed fall maintenance inspection on commercial HVAC system. Examined Honeywell control device showing signs of aging and weathering with adhesive tape around lower portion. Inspected terminal block connections and verified proper wiring configuration with all leads (green, white, red, yellow, and black) securely connected to appropriate terminals.
Clay B.
Clay B. Checked in
Completed fall maintenance inspection on commercial HVAC system. Examined Honeywell control device showing signs of aging and weathering with adhesive tape around lower portion. Inspected terminal block connections and verified proper wiring configuration with all leads (green, white, red, yellow, and black) securely connected to appropriate terminals.
Akron, OH 44306
Responded to no heat call at elderly customer's residence. Performed combustion analysis on furnace using Sauermann gas analyzer, which revealed suboptimal efficiency readings between 74.5-76.7%. Adjusted gas-air mixture to restore proper heating function and improve system performance.
Responded to no heat call at elderly customer's residence. Performed combustion analysis on furnace using Sauermann gas analyzer, which revealed suboptimal efficiency readings between 74.5-76.7%. Adjusted gas-air mixture to restore proper heating function and improve system performance.
Jake T.
Jake T. Checked in
Responded to no heat call at elderly customer's residence. Performed combustion analysis on furnace using Sauermann gas analyzer, which revealed suboptimal efficiency readings between 74.5-76.7%. Adjusted gas-air mixture to restore proper heating function and improve system performance.
Akron, OH 44301
Completed retrofit installation of Lennox furnace with integrated AC system. Installed new ductwork through block wall with proper penetration and sealing. Connected all necessary drainage lines, electrical components, and verified system operation according to manufacturer specifications.
Completed retrofit installation of Lennox furnace with integrated AC system. Installed new ductwork through block wall with proper penetration and sealing. Connected all necessary drainage lines, electrical components, and verified system operation according to manufacturer specifications.
Denver H.
Denver H. Checked in
Completed retrofit installation of Lennox furnace with integrated AC system. Installed new ductwork through block wall with proper penetration and sealing. Connected all necessary drainage lines, electrical components, and verified system operation according to manufacturer specifications.
Akron, OH 44319
Performed routine furnace maintenance under existing service plan for 10-year-old unit. Conducted combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings of 8.2% and safe CO levels of 7-12 ppm. All systems functioning within normal parameters; unit is properly maintained with service plan valid through 2026.
Performed routine furnace maintenance under existing service plan for 10-year-old unit. Conducted combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings of 8.2% and safe CO levels of 7-12 ppm. All systems functioning within normal parameters; unit is properly maintained with service plan valid through 2026.
Brynn L.
Brynn L. Checked in
Performed routine furnace maintenance under existing service plan for 10-year-old unit. Conducted combustion analysis using Testo 310 analyzer, confirming proper operation with Oâ‚‚ readings of 8.2% and safe CO levels of 7-12 ppm. All systems functioning within normal parameters; unit is properly maintained with service plan valid through 2026.
Akron, OH 44333
Performed diagnostic assessment on 16-year-old zoning gas furnace system where master bedroom thermostat was not maintaining set temperature (climbing from 69°F to 73°F). Inspected ductwork connections, wiring, and zone control components. Identified and corrected improper damper operation causing excess heat delivery to master zone.
Performed diagnostic assessment on 16-year-old zoning gas furnace system where master bedroom thermostat was not maintaining set temperature (climbing from 69°F to 73°F). Inspected ductwork connections, wiring, and zone control components. Identified and corrected improper damper operation causing excess heat delivery to master zone.
Jake T.
Jake T. Checked in
Performed diagnostic assessment on 16-year-old zoning gas furnace system where master bedroom thermostat was not maintaining set temperature (climbing from 69°F to 73°F). Inspected ductwork connections, wiring, and zone control components. Identified and corrected improper damper operation causing excess heat delivery to master zone.
Akron, OH 44333
Responded to service call for non-operational furnace. Upon inspection, accessed internal components of residential HVAC system by removing front panel. Diagnosed issue with furnace, performed necessary repairs, and verified proper operation before closing access panels. System now functioning correctly.
Responded to service call for non-operational furnace. Upon inspection, accessed internal components of residential HVAC system by removing front panel. Diagnosed issue with furnace, performed necessary repairs, and verified proper operation before closing access panels. System now functioning correctly.
Jake T.
Jake T. Checked in
Responded to service call for non-operational furnace. Upon inspection, accessed internal components of residential HVAC system by removing front panel. Diagnosed issue with furnace, performed necessary repairs, and verified proper operation before closing access panels. System now functioning correctly.
Akron, OH 44303
Akron, OH - Performed standard furnace clean and check service. Conducted combustion analysis using Bacharach analyzer, confirming proper operation with 96.3% efficiency, 6.1% COâ‚‚, and safe CO levels at 7ppm. System is operating within manufacturer specifications.
Joshua L.
Joshua L. Checked in
Performed standard furnace clean and check service. Conducted combustion analysis using Bacharach analyzer, confirming proper operation with 96.3% efficiency, 6.1% COâ‚‚, and safe CO levels at 7ppm. System is operating within manufacturer specifications.
Akron, OH 44319
Performed thermostat battery replacement and conducted comprehensive furnace operational check. Analysis with Bacharach gas analyzer showed natural gas combustion readings with Oâ‚‚ at 8.6%, CO at 26 ppm, efficiency at 80.5%, COâ‚‚ at 7.0%, and stack temperature at 349°F, confirming system is operating within acceptable parameters.
Performed thermostat battery replacement and conducted comprehensive furnace operational check. Analysis with Bacharach gas analyzer showed natural gas combustion readings with Oâ‚‚ at 8.6%, CO at 26 ppm, efficiency at 80.5%, COâ‚‚ at 7.0%, and stack temperature at 349°F, confirming system is operating within acceptable parameters.
Joshua L.
Joshua L. Checked in
Performed thermostat battery replacement and conducted comprehensive furnace operational check. Analysis with Bacharach gas analyzer showed natural gas combustion readings with Oâ‚‚ at 8.6%, CO at 26 ppm, efficiency at 80.5%, COâ‚‚ at 7.0%, and stack temperature at 349°F, confirming system is operating within acceptable parameters.
Akron, OH 44319
Responded to service call for commercial furnace not heating above 65°F. Inspected system and found dirty air filters restricting airflow. Replaced multiple KOCH filters in both main housing and ceiling/wall mounted air handling units. System now operating properly with improved airflow and heating capacity.
Responded to service call for commercial furnace not heating above 65°F. Inspected system and found dirty air filters restricting airflow. Replaced multiple KOCH filters in both main housing and ceiling/wall mounted air handling units. System now operating properly with improved airflow and heating capacity.
Deepak R.
Deepak R. Checked in
Responded to service call for commercial furnace not heating above 65°F. Inspected system and found dirty air filters restricting airflow. Replaced multiple KOCH filters in both main housing and ceiling/wall mounted air handling units. System now operating properly with improved airflow and heating capacity.
Akron, OH 44303

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.