Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026.

The most recent job was on November 13, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Denver H.
Denver H. Checked in
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Akron, OH 44306
Performed heating maintenance on two basement-installed gas furnaces (approximately 6 and 20 years old), including visual borescope inspection of the internal heat exchanger and flue passages, which revealed light scale and corrosion buildup around the opening rim. Inspected the gas supply piping and shutoff valve, noting minor discoloration on the threaded brass fitting, and verified the control module and system operation, with service tags updated on both units.
Performed heating maintenance on two basement-installed gas furnaces (approximately 6 and 20 years old), including visual borescope inspection of the internal heat exchanger and flue passages, which revealed light scale and corrosion buildup around the opening rim. Inspected the gas supply piping and shutoff valve, noting minor discoloration on the threaded brass fitting, and verified the control module and system operation, with service tags updated on both units.
Nick D.
Nick D. Checked in
Performed heating maintenance on two basement-installed gas furnaces (approximately 6 and 20 years old), including visual borescope inspection of the internal heat exchanger and flue passages, which revealed light scale and corrosion buildup around the opening rim. Inspected the gas supply piping and shutoff valve, noting minor discoloration on the threaded brass fitting, and verified the control module and system operation, with service tags updated on both units.
Akron, OH 44333
Akron, OH - Performed annual heating maintenance on a 2-year-old gas furnace located in the basement, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: Oâ‚‚ 5.9%, COâ‚‚ 8.4%, CO 44 ppm, stack temperature 87°F, and 98.5% efficiency. Furnace is operating properly, and the customer is due for maintenance plan renewal.
Maddex H.
Maddex H. Checked in
Performed annual heating maintenance on a 2-year-old gas furnace located in the basement, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: Oâ‚‚ 5.9%, COâ‚‚ 8.4%, CO 44 ppm, stack temperature 87°F, and 98.5% efficiency. Furnace is operating properly, and the customer is due for maintenance plan renewal.
Akron, OH 44321
Completed a full HVAC system installation, including a new outdoor condenser unit mounted on a wall bracket with a code-compliant electrical disconnect and conduit run. Insulated refrigerant lines were routed through the exterior wall, and a condensate drain line was installed and terminated away from the structure. Refrigerant line sets and electrical connections were secured and sealed, with the system commissioned and operating within specifications.
Completed a full HVAC system installation, including a new outdoor condenser unit mounted on a wall bracket with a code-compliant electrical disconnect and conduit run. Insulated refrigerant lines were routed through the exterior wall, and a condensate drain line was installed and terminated away from the structure. Refrigerant line sets and electrical connections were secured and sealed, with the system commissioned and operating within specifications.
Adam A.
Adam A. Checked in
Completed a full HVAC system installation, including a new outdoor condenser unit mounted on a wall bracket with a code-compliant electrical disconnect and conduit run. Insulated refrigerant lines were routed through the exterior wall, and a condensate drain line was installed and terminated away from the structure. Refrigerant line sets and electrical connections were secured and sealed, with the system commissioned and operating within specifications.
Akron, OH 44321
Akron, OH - Performed seasonal heating maintenance on a 17-year-old natural gas furnace, including inspection of the combustion system and operational check of the unit. Combustion analysis was recorded at 9.5% Oâ‚‚, 6.4% COâ‚‚, 6 ppm CO, 329°F stack temperature, and 81.2% efficiency, with CO within safe limits. The furnace was left operating normally at completion.
Maddex H.
Maddex H. Checked in
Performed seasonal heating maintenance on a 17-year-old natural gas furnace, including inspection of the combustion system and operational check of the unit. Combustion analysis was recorded at 9.5% Oâ‚‚, 6.4% COâ‚‚, 6 ppm CO, 329°F stack temperature, and 81.2% efficiency, with CO within safe limits. The furnace was left operating normally at completion.
Akron, OH 44319
Akron, OH - Performed seasonal heating system maintenance and combustion analysis on the natural gas furnace. Analyzer readings were within normal operating range: Oâ‚‚ 7.8%, CO 15 ppm, COâ‚‚ 7.4%, and stack temperature 91°F, confirming safe and proper combustion.
Maddex H.
Maddex H. Checked in
Performed seasonal heating system maintenance and combustion analysis on the natural gas furnace. Analyzer readings were within normal operating range: Oâ‚‚ 7.8%, CO 15 ppm, COâ‚‚ 7.4%, and stack temperature 91°F, confirming safe and proper combustion.
Akron, OH 44310
Performed an on-site estimate for installing a gas line to serve a fireplace. Inspected the masonry firebox, noting existing electrical cabling and soot buildup inside the enclosure, and evaluated the adjacent mechanical space, where existing black iron piping and a duct cabinet were identified as potential routing and tie-in points. Documented site conditions with photos to determine pipe routing, termination location, and material requirements for the new gas line.
Performed an on-site estimate for installing a gas line to serve a fireplace. Inspected the masonry firebox, noting existing electrical cabling and soot buildup inside the enclosure, and evaluated the adjacent mechanical space, where existing black iron piping and a duct cabinet were identified as potential routing and tie-in points. Documented site conditions with photos to determine pipe routing, termination location, and material requirements for the new gas line.
Triston Y.
Triston Y. Checked in
Performed an on-site estimate for installing a gas line to serve a fireplace. Inspected the masonry firebox, noting existing electrical cabling and soot buildup inside the enclosure, and evaluated the adjacent mechanical space, where existing black iron piping and a duct cabinet were identified as potential routing and tie-in points. Documented site conditions with photos to determine pipe routing, termination location, and material requirements for the new gas line.
Akron, OH 44312
Performed annual heating maintenance on a gas furnace, inspecting the blower assembly, burners, heat exchanger, gas valve, wiring, and control board with the cabinet panels removed. Burners ignited and operated with a stable blue flame, and the unit cycled properly through heating operation. Noted light rust on the burner components and dust and dirt buildup inside the cabinet, and checked the air filter condition.
Performed annual heating maintenance on a gas furnace, inspecting the blower assembly, burners, heat exchanger, gas valve, wiring, and control board with the cabinet panels removed. Burners ignited and operated with a stable blue flame, and the unit cycled properly through heating operation. Noted light rust on the burner components and dust and dirt buildup inside the cabinet, and checked the air filter condition.
Zack W.
Zack W. Checked in
Performed annual heating maintenance on a gas furnace, inspecting the blower assembly, burners, heat exchanger, gas valve, wiring, and control board with the cabinet panels removed. Burners ignited and operated with a stable blue flame, and the unit cycled properly through heating operation. Noted light rust on the burner components and dust and dirt buildup inside the cabinet, and checked the air filter condition.
Akron, OH 44314
Akron, OH - Performed an on-site evaluation for replacement of an existing upflow gas furnace in a basement utility space. Removed the front access panel and inspected the inducer motor, control board, wiring, and flue connection, noting heavy dust accumulation, surface wear, and rust on the adjacent gas piping. Documented the unit's condition, flue configuration, and attached ductwork to determine replacement scope and compatibility.
Justin B.
Justin B. Checked in
Performed an on-site evaluation for replacement of an existing upflow gas furnace in a basement utility space. Removed the front access panel and inspected the inducer motor, control board, wiring, and flue connection, noting heavy dust accumulation, surface wear, and rust on the adjacent gas piping. Documented the unit's condition, flue configuration, and attached ductwork to determine replacement scope and compatibility.
Akron, OH 44301
Akron, OH - Reconnected the sink to the countertop and re-secured the loose drain plumbing beneath the basin. Inspected the under-sink assembly, including the P-trap slip-joint fittings, garbage disposal connection, and flexible drain hose, and confirmed all connections were tight and properly aligned. Noted existing water staining on the cabinet back wall from prior moisture exposure.
Triston Y.
Triston Y. Checked in
Reconnected the sink to the countertop and re-secured the loose drain plumbing beneath the basin. Inspected the under-sink assembly, including the P-trap slip-joint fittings, garbage disposal connection, and flexible drain hose, and confirmed all connections were tight and properly aligned. Noted existing water staining on the cabinet back wall from prior moisture exposure.
Akron, OH 44314
Performed an on-site evaluation and replacement estimate for a furnace and air conditioning retrofit. Inspected the existing outdoor condenser unit, which shows corrosion on the fan guard and hub, along with its disconnect and electrical whip, and assessed the gas-fired upright furnace with its burner assembly, blower motor, control board, flue connection, supply plenum, and gas supply piping for replacement scope. No frost, rust, or visible damage was found on the furnace cabinet, and the condenser pad and surrounding area were noted for clearing of debris prior to installation.
Performed an on-site evaluation and replacement estimate for a furnace and air conditioning retrofit. Inspected the existing outdoor condenser unit, which shows corrosion on the fan guard and hub, along with its disconnect and electrical whip, and assessed the gas-fired upright furnace with its burner assembly, blower motor, control board, flue connection, supply plenum, and gas supply piping for replacement scope. No frost, rust, or visible damage was found on the furnace cabinet, and the condenser pad and surrounding area were noted for clearing of debris prior to installation.
Justin B.
Justin B. Checked in
Performed an on-site evaluation and replacement estimate for a furnace and air conditioning retrofit. Inspected the existing outdoor condenser unit, which shows corrosion on the fan guard and hub, along with its disconnect and electrical whip, and assessed the gas-fired upright furnace with its burner assembly, blower motor, control board, flue connection, supply plenum, and gas supply piping for replacement scope. No frost, rust, or visible damage was found on the furnace cabinet, and the condenser pad and surrounding area were noted for clearing of debris prior to installation.
Akron, OH 44319
Akron, OH - Responded to a no-heat call on a 14-year-old gas furnace that would not start. Diagnosed and corrected the cause of the failure, restored the unit to operation, and verified safe performance with a combustion analyzer, which showed 7.0% Oâ‚‚ and 6 ppm CO. Heat is now functioning properly.
Nick D.
Nick D. Checked in
Responded to a no-heat call on a 14-year-old gas furnace that would not start. Diagnosed and corrected the cause of the failure, restored the unit to operation, and verified safe performance with a combustion analyzer, which showed 7.0% Oâ‚‚ and 6 ppm CO. Heat is now functioning properly.
Akron, OH 44319
Performed fall heating maintenance on two natural gas furnaces, including combustion analysis with a calibrated flue gas analyzer to verify safe, efficient operation. Readings on both units were within normal parameters, with CO at 12–13 ppm, O2 at 6.9–7.3%, and CO2 at 7.6–7.8%, confirming proper combustion and venting.
Performed fall heating maintenance on two natural gas furnaces, including combustion analysis with a calibrated flue gas analyzer to verify safe, efficient operation. Readings on both units were within normal parameters, with CO at 12–13 ppm, O2 at 6.9–7.3%, and CO2 at 7.6–7.8%, confirming proper combustion and venting.
Jake T.
Jake T. Checked in
Performed fall heating maintenance on two natural gas furnaces, including combustion analysis with a calibrated flue gas analyzer to verify safe, efficient operation. Readings on both units were within normal parameters, with CO at 12–13 ppm, O2 at 6.9–7.3%, and CO2 at 7.6–7.8%, confirming proper combustion and venting.
Akron, OH 44319
Performed an on-site evaluation for a possible ductless mini split installation and system zoning in the basement mechanical and storage area. Inspected the existing insulated rectangular sheet-metal trunk ductwork, access panel, and adjacent copper and black piping, finding no visible corrosion, frost, or damage, and documented the available wall and ceiling space, clearances, and equipment locations for indoor head placement and line set routing. Findings were recorded with photos to support equipment sizing and zoning recommendations.
Performed an on-site evaluation for a possible ductless mini split installation and system zoning in the basement mechanical and storage area. Inspected the existing insulated rectangular sheet-metal trunk ductwork, access panel, and adjacent copper and black piping, finding no visible corrosion, frost, or damage, and documented the available wall and ceiling space, clearances, and equipment locations for indoor head placement and line set routing. Findings were recorded with photos to support equipment sizing and zoning recommendations.
Justin B.
Justin B. Checked in
Performed an on-site evaluation for a possible ductless mini split installation and system zoning in the basement mechanical and storage area. Inspected the existing insulated rectangular sheet-metal trunk ductwork, access panel, and adjacent copper and black piping, finding no visible corrosion, frost, or damage, and documented the available wall and ceiling space, clearances, and equipment locations for indoor head placement and line set routing. Findings were recorded with photos to support equipment sizing and zoning recommendations.
Akron, OH 44333
Akron, OH - Responded to a no-heat call on a natural gas furnace and diagnosed a failed hot surface ignitor, which was preventing ignition. After restoring heat operation, performed a combustion analysis showing O2 at 5.4%, CO at 48 ppm, CO2 at 8.7%, and 98.4% efficiency, confirming the unit is operating within acceptable parameters.
Zack W.
Zack W. Checked in
Responded to a no-heat call on a natural gas furnace and diagnosed a failed hot surface ignitor, which was preventing ignition. After restoring heat operation, performed a combustion analysis showing O2 at 5.4%, CO at 48 ppm, CO2 at 8.7%, and 98.4% efficiency, confirming the unit is operating within acceptable parameters.
Akron, OH 44333
Removed two existing 40-gallon water heaters and installed a new 50-gallon Bradford White gas water heater, reworking the copper water supply lines with soldered joints, a brass mixing valve, and isolation ball valves. Installed a thermal expansion tank, reconnected the gas supply with a shutoff valve, and reconfigured the flue with a draft hood and galvanized vent connector routed to the existing chimney. System inspected with no visible leaks or defects.
Removed two existing 40-gallon water heaters and installed a new 50-gallon Bradford White gas water heater, reworking the copper water supply lines with soldered joints, a brass mixing valve, and isolation ball valves. Installed a thermal expansion tank, reconnected the gas supply with a shutoff valve, and reconfigured the flue with a draft hood and galvanized vent connector routed to the existing chimney. System inspected with no visible leaks or defects.
Triston Y.
Triston Y. Checked in
Removed two existing 40-gallon water heaters and installed a new 50-gallon Bradford White gas water heater, reworking the copper water supply lines with soldered joints, a brass mixing valve, and isolation ball valves. Installed a thermal expansion tank, reconnected the gas supply with a shutoff valve, and reconfigured the flue with a draft hood and galvanized vent connector routed to the existing chimney. System inspected with no visible leaks or defects.
Akron, OH 44321
Performed scheduled maintenance on a ceiling-suspended Reznor unit heater serving a large indoor athletic facility, inspecting the cabinet, louvered discharge grille, electrical conduit, and flue venting; no frost, rust, or damage was observed on the unit or its mounting. Inspection also identified a visible crack in an insulated pipe or tubular component, along with minor surface rust on an adjacent pipe, which should be evaluated for repair or replacement to prevent further deterioration.
Performed scheduled maintenance on a ceiling-suspended Reznor unit heater serving a large indoor athletic facility, inspecting the cabinet, louvered discharge grille, electrical conduit, and flue venting; no frost, rust, or damage was observed on the unit or its mounting. Inspection also identified a visible crack in an insulated pipe or tubular component, along with minor surface rust on an adjacent pipe, which should be evaluated for repair or replacement to prevent further deterioration.
Roderick H.
Roderick H. Checked in
Performed scheduled maintenance on a ceiling-suspended Reznor unit heater serving a large indoor athletic facility, inspecting the cabinet, louvered discharge grille, electrical conduit, and flue venting; no frost, rust, or damage was observed on the unit or its mounting. Inspection also identified a visible crack in an insulated pipe or tubular component, along with minor surface rust on an adjacent pipe, which should be evaluated for repair or replacement to prevent further deterioration.
Akron, OH 44313
Performed a combustion analysis on the Knight modulating condensing boiler using a Bacharach Fyrite InTech analyzer, recording O2 at 6.9%, CO at 25 ppm, CO2 at 7.9%, and combustion efficiency of 90.6% on natural gas. Verified boiler operation at 99% modulation with a 10°F delta T, 125°F flue temperature, 12.8 µA flame signal, and approximately 6,996 RPM fan speed, confirming the unit is operating within normal parameters. Inspected and tested the furnace for proper operation as part of the system check.
Performed a combustion analysis on the Knight modulating condensing boiler using a Bacharach Fyrite InTech analyzer, recording O2 at 6.9%, CO at 25 ppm, CO2 at 7.9%, and combustion efficiency of 90.6% on natural gas. Verified boiler operation at 99% modulation with a 10°F delta T, 125°F flue temperature, 12.8 µA flame signal, and approximately 6,996 RPM fan speed, confirming the unit is operating within normal parameters. Inspected and tested the furnace for proper operation as part of the system check.
Zack W.
Zack W. Checked in
Performed a combustion analysis on the Knight modulating condensing boiler using a Bacharach Fyrite InTech analyzer, recording O2 at 6.9%, CO at 25 ppm, CO2 at 7.9%, and combustion efficiency of 90.6% on natural gas. Verified boiler operation at 99% modulation with a 10°F delta T, 125°F flue temperature, 12.8 µA flame signal, and approximately 6,996 RPM fan speed, confirming the unit is operating within normal parameters. Inspected and tested the furnace for proper operation as part of the system check.
Akron, OH 44303
Akron, OH - Performed annual heating maintenance on a 15-year-old gas furnace, including a full system inspection and operational check. Removed the heavily soiled, dust-laden air filter and installed a clean replacement to restore proper airflow and protect the blower and heat exchanger.
Maddex H.
Maddex H. Checked in
Performed annual heating maintenance on a 15-year-old gas furnace, including a full system inspection and operational check. Removed the heavily soiled, dust-laden air filter and installed a clean replacement to restore proper airflow and protect the blower and heat exchanger.
Akron, OH 44314
Responded to a no-heat call and performed a diagnostic inspection of the furnace system, including the Nest thermostat and unit controls, with the filter condition noted as unknown and in need of inspection and replacement. During the service, heavy corrosion was documented at the bottom of the electrical panel enclosure, which presents a safety and reliability concern for the electrical supply and should be evaluated by a licensed electrician.
Responded to a no-heat call and performed a diagnostic inspection of the furnace system, including the Nest thermostat and unit controls, with the filter condition noted as unknown and in need of inspection and replacement. During the service, heavy corrosion was documented at the bottom of the electrical panel enclosure, which presents a safety and reliability concern for the electrical supply and should be evaluated by a licensed electrician.
Tom M.
Tom M. Checked in
Responded to a no-heat call and performed a diagnostic inspection of the furnace system, including the Nest thermostat and unit controls, with the filter condition noted as unknown and in need of inspection and replacement. During the service, heavy corrosion was documented at the bottom of the electrical panel enclosure, which presents a safety and reliability concern for the electrical supply and should be evaluated by a licensed electrician.
Akron, OH 44301

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.