Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026. The most recent job was on November 13, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Completed a gas furnace retrofit, installing the new unit with connected supply and return ductwork, black iron gas piping with sediment trap and shutoff, and PVC venting and condensate drain. Relocated the existing gas water heater, reconnecting the gas supply, copper water lines, expansion tank, and flue vent to the chimney with proper clearances. Verified all connections and combustion venting were secure, and cleaned the work area upon completion.
Performed heating maintenance on two basement-installed gas furnaces (approximately 6 and 20 years old), including visual borescope inspection of the internal heat exchanger and flue passages, which revealed light scale and corrosion buildup around the opening rim. Inspected the gas supply piping and shutoff valve, noting minor discoloration on the threaded brass fitting, and verified the control module and system operation, with service tags updated on both units.
Performed annual heating maintenance on a 2-year-old gas furnace located in the basement, including a combustion analysis with a Bacharach analyzer. Readings were within normal operating range: Oâ‚‚ 5.9%, COâ‚‚ 8.4%, CO 44 ppm, stack temperature 87°F, and 98.5% efficiency. Furnace is operating properly, and the customer is due for maintenance plan renewal.
Completed a full HVAC system installation, including a new outdoor condenser unit mounted on a wall bracket with a code-compliant electrical disconnect and conduit run. Insulated refrigerant lines were routed through the exterior wall, and a condensate drain line was installed and terminated away from the structure. Refrigerant line sets and electrical connections were secured and sealed, with the system commissioned and operating within specifications.
Performed seasonal heating maintenance on a 17-year-old natural gas furnace, including inspection of the combustion system and operational check of the unit. Combustion analysis was recorded at 9.5% Oâ‚‚, 6.4% COâ‚‚, 6 ppm CO, 329°F stack temperature, and 81.2% efficiency, with CO within safe limits. The furnace was left operating normally at completion.
Performed seasonal heating system maintenance and combustion analysis on the natural gas furnace. Analyzer readings were within normal operating range: Oâ‚‚ 7.8%, CO 15 ppm, COâ‚‚ 7.4%, and stack temperature 91°F, confirming safe and proper combustion.
Performed an on-site estimate for installing a gas line to serve a fireplace. Inspected the masonry firebox, noting existing electrical cabling and soot buildup inside the enclosure, and evaluated the adjacent mechanical space, where existing black iron piping and a duct cabinet were identified as potential routing and tie-in points. Documented site conditions with photos to determine pipe routing, termination location, and material requirements for the new gas line.
Performed annual heating maintenance on a gas furnace, inspecting the blower assembly, burners, heat exchanger, gas valve, wiring, and control board with the cabinet panels removed. Burners ignited and operated with a stable blue flame, and the unit cycled properly through heating operation. Noted light rust on the burner components and dust and dirt buildup inside the cabinet, and checked the air filter condition.
Performed an on-site evaluation for replacement of an existing upflow gas furnace in a basement utility space. Removed the front access panel and inspected the inducer motor, control board, wiring, and flue connection, noting heavy dust accumulation, surface wear, and rust on the adjacent gas piping. Documented the unit's condition, flue configuration, and attached ductwork to determine replacement scope and compatibility.
Reconnected the sink to the countertop and re-secured the loose drain plumbing beneath the basin. Inspected the under-sink assembly, including the P-trap slip-joint fittings, garbage disposal connection, and flexible drain hose, and confirmed all connections were tight and properly aligned. Noted existing water staining on the cabinet back wall from prior moisture exposure.
Performed an on-site evaluation and replacement estimate for a furnace and air conditioning retrofit. Inspected the existing outdoor condenser unit, which shows corrosion on the fan guard and hub, along with its disconnect and electrical whip, and assessed the gas-fired upright furnace with its burner assembly, blower motor, control board, flue connection, supply plenum, and gas supply piping for replacement scope. No frost, rust, or visible damage was found on the furnace cabinet, and the condenser pad and surrounding area were noted for clearing of debris prior to installation.
Responded to a no-heat call on a 14-year-old gas furnace that would not start. Diagnosed and corrected the cause of the failure, restored the unit to operation, and verified safe performance with a combustion analyzer, which showed 7.0% Oâ‚‚ and 6 ppm CO. Heat is now functioning properly.
Performed fall heating maintenance on two natural gas furnaces, including combustion analysis with a calibrated flue gas analyzer to verify safe, efficient operation. Readings on both units were within normal parameters, with CO at 12–13 ppm, O2 at 6.9–7.3%, and CO2 at 7.6–7.8%, confirming proper combustion and venting.
Performed an on-site evaluation for a possible ductless mini split installation and system zoning in the basement mechanical and storage area. Inspected the existing insulated rectangular sheet-metal trunk ductwork, access panel, and adjacent copper and black piping, finding no visible corrosion, frost, or damage, and documented the available wall and ceiling space, clearances, and equipment locations for indoor head placement and line set routing. Findings were recorded with photos to support equipment sizing and zoning recommendations.
Responded to a no-heat call on a natural gas furnace and diagnosed a failed hot surface ignitor, which was preventing ignition. After restoring heat operation, performed a combustion analysis showing O2 at 5.4%, CO at 48 ppm, CO2 at 8.7%, and 98.4% efficiency, confirming the unit is operating within acceptable parameters.
Removed two existing 40-gallon water heaters and installed a new 50-gallon Bradford White gas water heater, reworking the copper water supply lines with soldered joints, a brass mixing valve, and isolation ball valves. Installed a thermal expansion tank, reconnected the gas supply with a shutoff valve, and reconfigured the flue with a draft hood and galvanized vent connector routed to the existing chimney. System inspected with no visible leaks or defects.
Performed scheduled maintenance on a ceiling-suspended Reznor unit heater serving a large indoor athletic facility, inspecting the cabinet, louvered discharge grille, electrical conduit, and flue venting; no frost, rust, or damage was observed on the unit or its mounting. Inspection also identified a visible crack in an insulated pipe or tubular component, along with minor surface rust on an adjacent pipe, which should be evaluated for repair or replacement to prevent further deterioration.
Performed a combustion analysis on the Knight modulating condensing boiler using a Bacharach Fyrite InTech analyzer, recording O2 at 6.9%, CO at 25 ppm, CO2 at 7.9%, and combustion efficiency of 90.6% on natural gas. Verified boiler operation at 99% modulation with a 10°F delta T, 125°F flue temperature, 12.8 µA flame signal, and approximately 6,996 RPM fan speed, confirming the unit is operating within normal parameters. Inspected and tested the furnace for proper operation as part of the system check.
Performed annual heating maintenance on a 15-year-old gas furnace, including a full system inspection and operational check. Removed the heavily soiled, dust-laden air filter and installed a clean replacement to restore proper airflow and protect the blower and heat exchanger.
Responded to a no-heat call and performed a diagnostic inspection of the furnace system, including the Nest thermostat and unit controls, with the filter condition noted as unknown and in need of inspection and replacement. During the service, heavy corrosion was documented at the bottom of the electrical panel enclosure, which presents a safety and reliability concern for the electrical supply and should be evaluated by a licensed electrician.