Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026. The most recent job was on November 10, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 938 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Removed the existing furnace and installed a new gas-fired upflow furnace, connecting it to the existing galvanized supply plenum and ductwork with foil-taped seams. Installed PVC combustion air intake and exhaust venting with a condensate drain line, reconnected the gas supply with a flexible line and shutoff valve, and completed the electrical connections. Sealed pipe penetrations and labeled the unit, with all connections secure and no visible leaks or damage.
Responded to a no-heat call on a gas-fired system and performed a combustion analysis, which returned O2 8.9%, CO2 6.8%, CO 19 ppm, and 80.6% efficiency on natural gas. Inspected the hydronic components and noted heavy corrosion and mineral deposits on the cast iron air separator, along with verdigris at copper pipe fittings and rust staining on the adjacent wall, indicating possible past or active leakage. Recommend further evaluation of the corroded hydronic components and monitoring for leaks.
Installed a new 40-gallon Bradford White natural gas tank water heater with a power anode rod to extend tank life and reduce corrosion. Connected the gas supply, venting, and copper water lines, and installed an expansion tank to manage thermal expansion within the system.
Performed annual heating maintenance on an 11-year-old basement-installed gas furnace, including inspection of the combustion system and operating components. Verified safe, efficient operation with a combustion analysis on natural gas showing 94.3% efficiency, 6 ppm CO, 11.4% Oâ‚‚, 5.4% COâ‚‚, and a 100°F stack temperature.
Performed a routine tune-up on the approximately 10-year-old basement furnace, which was operating normally with no reported issues. Conducted a combustion analysis on natural gas, with readings of 9.06% O2, 6.65% CO2, and 5 ppm CO, confirming safe and proper combustion within acceptable limits. Furnace was left in good working order.
Performed a complete furnace cleaning and safety inspection, including cleaning of burners and heat exchanger access points and verifying proper ignition and operation. Conducted a combustion analysis with a calibrated flue gas analyzer, recording Oâ‚‚ at 8.8% and CO at 20 ppm, confirming combustion within acceptable operating parameters. System operating normally at completion.
Performed seasonal heating maintenance on an 8-year-old gas furnace, including inspection of the burner assembly, heat exchanger, and combustion components. Conducted a combustion analysis on natural gas, with readings of 93.1% efficiency, 8.3% Oâ‚‚, 7.1% COâ‚‚, 16 ppm CO, and a 110°F stack temperature, confirming safe and efficient operation within acceptable parameters.
Performed scheduled heating maintenance on a 5-year-old gas furnace located in the garage, including inspection of key components and operational checks. Conducted a combustion analysis using a flue gas analyzer, recording O2 at 6.73%, CO at 16 ppm, and CO2 at 7.95%, confirming the unit is burning cleanly with CO levels within acceptable range.
Completed new construction installation of two Lennox gas furnaces with matching evaporator coil cabinets, including PVC combustion venting and condensate drainage, flexible gas line connections, and insulated refrigerant line sets routed through the structure. Installed and connected sheet-metal supply and return ductwork with AprilAire accessory components, set both units on a level concrete pad, and secured all electrical conduit and control wiring. Systems are ready for startup and commissioning.
Performed seasonal fall heating maintenance on the natural gas furnace, including a combustion analysis with a calibrated flue gas analyzer to verify safe and efficient operation. Readings showed O2 at 12.8%, CO at 12 ppm, CO2 at 4.57%, and steady-state efficiency of 85.2%, confirming CO levels within acceptable limits and the unit operating properly for the heating season.
Responded to a reported condensation line leak and possible gas leak at the furnace, inspecting the furnace area and the surrounding ductwork, drain/vent piping, and black iron gas piping. Sealed the gas pipe penetration and framing seams with foam, and no visible signs of corrosion, frost, or ice were found at the inspected components.
Performed a complete furnace tune-up, including cleaning and inspection of the unit and its components. Conducted a combustion analysis on the natural gas appliance, with readings of 6.40% O2, 12 ppm CO, and 8.13% CO2, confirming safe, within-range combustion and proper operation.
Performed seasonal heating maintenance on a 5-year-old natural gas furnace, including a combustion analysis with a Bacharach Fyrite InTech analyzer. Results showed O2 at 7.0%, CO2 at 7.9%, CO at 16 ppm, and steady-state efficiency of 93.8%, indicating safe, efficient combustion within normal operating parameters. No visible rust, frost, or damage observed at the unit.
Responded to a reported gas leak with service shut off by the utility. Inspected the exterior meter assembly and identified a heavily corroded black iron gas line at the foundation wall with moisture and staining at its base, indicating the likely leak source. Documented conditions with photos, noting overgrown vegetation obstructing meter access that should be cleared.
Performed scheduled preventive maintenance on a 2-year-old gas furnace, including a combustion analysis on natural gas to verify safe and efficient operation. Flue gas readings were within acceptable range at 10.26% O2, 13 ppm CO, and 5.98% CO2, confirming clean combustion and no carbon monoxide concerns. The system was left operating normally.
Performed seasonal heating maintenance on a 15-year-old natural gas furnace, including inspection of the burner assembly, heat exchanger, and combustion components for proper operation. Conducted a combustion analysis with a calibrated analyzer, recording O2 at 7.85%, CO at 20 ppm, CO2 at 7.33%, and net efficiency of 91.4%, confirming safe CO levels and stable, efficient combustion within acceptable operating parameters.
Re-plumbed the humidifier drain line at the air handler and relocated several 90-degree elbows to eliminate restrictions causing poor drainage. Reconfigured the PVC drain assembly with a trap, tee, and properly supported vertical and horizontal runs to the floor drain, securing the piping with brackets and clips to ensure positive slope and unobstructed flow.
Performed annual heating maintenance on the gas furnace, including inspection of the burner assembly, heat exchanger, and venting, along with cleaning of key components and verification of safe operation. Conducted a combustion analysis on natural gas, recording O2 at 10.05%, CO at 5 ppm, and CO2 at 6.10%, with CO levels well within acceptable limits and combustion confirmed to be clean and safe at system startup.
Installed a new 40-gallon Bradford White gas water heater, connecting the gas supply, cold and hot water lines with shutoff valves, and the flue venting to the existing system. Verified the thermal expansion tank installation, checked all connections for leaks, and tested burner ignition and thermostat operation to confirm proper function.
Performed annual heating maintenance on a 6-year-old furnace, including inspection of the combustion system and operating components. Combustion analysis was performed with CO readings of 50–51 ppm and O2 levels of 4.5–5.4%, indicating safe, efficient operation within acceptable limits.