Since 1974, Lakes Heating & Air Conditioning has been Northeast Ohio’s most trusted heating, cooling, and air quality specialists. Fairlawn residents rely on Lakes for top-quality HVAC repair, replacement, maintenance services, and leading geothermal and air quality services. Whether you need service for new construction or an existing home or business, Lakes is your one-stop shop for industry-leading HVAC services you can count on.
Schedule your free HVAC estimate in Fairlawn, OH, today!

Air Conditioning Installation & Maintenance
To keep you comfortable, Lakes Heating & Air Conditioning provides industry-best air conditioning services in Fairlawn, including:
- AC installation and replacement: Our seasoned AC technicians, who are licensed and insured and work with all brands, will help you choose the ideal type and size of AC for your home, whether you choose traditional, heat pump, or ductless AC.
- AC maintenance: Routine AC maintenance will help prevent unexpected breakdowns, keep your AC functioning at peak efficiency, and lower your energy bills.
- Commercial cooling services: Fairlawn businesses rely on Lakes for top-quality AC installation, repair, and maintenance services.
Top-Rated Heating Replacement & Repair Services
Lakes keeps Fairlawn homes and businesses warm all winter with high-quality heating services, including:
- Heating installation and replacement: We are expert installers for all types of heating systems, including furnaces, boilers, radiant heating, and snowmelt systems.
- Heating repair: From heat pumps to geothermal units, Lakes Heating expertly repairs all types and brands of heating systems.
- Heating maintenance: We recommend scheduling our maintenance services in the fall, before the winter season kicks in, to ensure your heater is ready to go.
- Commercial heating services: We proudly provide the industry’s best commercial heating installation, repair, and maintenance services for all heating systems.
Thorough Geothermal Services in Fairlawn
Lakes Heating & Cooling is proud to be a leader in Earth-friendly home comfort solutions by providing a one-stop shop for code-compliant geothermal services. Lakes Heating expertly provides:
- Geothermal installation: Our licensed technicians will install a ground loop of piping, ductwork (if needed), and the geothermal heat pump before making all the necessary connections and tests to ensure your system is functioning optimally.
- Geothermal repair: Though geothermal systems are known for their durability and longevity, we expertly repair any issues and provide emergency repairs if necessary.
Air Quality Services You Can Rely On
Lakes provides a full menu of leading indoor air quality services for Fairlawn homes and businesses, including professional installation of:
- Air cleaners and purifiers: Air cleaners dramatically reduce dust, pollen, pet dander, smoke, odors, and other harmful particles from the air.
- Air scrubbers: Air scrubbers remove allergens, germs, and viruses from the air and surfaces in your home or office.
- Thermostats: We expertly install and repair smart thermostats and other types. We ensure they are installed correctly and in the proper location for your space.
- CO detection: Proper installation and maintenance for your carbon monoxide detectors save lives!
- Humidifiers and dehumidifiers: Lakes expertly installs whole-home humidifiers and dehumidifiers to restore a healthy moisture balance to your indoor air.
Schedule Services With Lakes Heating & Air Conditioning in Fairlawn
Trusted and respected in your home and business since 1974, the Lakes Heating & Cooling team is eager to be your lifetime provider of heating, cooling, and air quality services in Fairlawn. You can count on Lakes because our ACCA-accredited company:
- Services all brands
- Provides free estimates on replacement quotes and service calls
- Delivers upfront pricing
- Offers financing options, special deals, and much more!
Get a heating or cooling technician in your Fairlawn home or business today by contacting Lakes now!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Fairlawn, OH between June 2026 and October 2026. The most recent job was on October 8, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 36 jobs in Fairlawn, OH in the last 12 months.Recent Jobs and Reviews in Fairlawn, OH
Fairlawn, OH at a glance
Job Locations and Reviews
# HVAC Service Report
Responded to service call for non-operational Trane rooftop unit G on commercial building. Upon arrival, conducted visual inspection of the packaged rooftop unit and accessed internal components to diagnose the failure. Investigation revealed issues with the gas valve assembly requiring attention. Inspected gas valve connections, wiring harness including orange, blue, red, and purple control wires, and associated gas piping. Verified proper wire terminations at gas valve and checked for secure mounting of all components. Examined condition of filter drier and associated refrigerant lines. Restored unit to operational status and verified proper system function before departure.
Completed maintenance on two heating systems, both 5-10 years old, as part of first-call MVP heat service. Performed combustion analysis on both units using Bacharach analyzer, with first system showing 85.5% efficiency, 9.9% O2, 3 ppm CO, and 6.2% CO2, while second system demonstrated improved performance at 96.3% efficiency, 8.0% O2, 11 ppm CO, and 7.3% CO2. All readings within acceptable parameters for natural gas equipment.
Responded to service call for Mitsubishi mini-split system displaying AE error code. Inspected both outdoor condenser unit located on flat roof and indoor air handler mounted in interior space. Diagnosed error code, performed necessary troubleshooting and system diagnostics, and resolved the fault condition. Verified proper operation of both indoor and outdoor units upon completion, with system returning to normal functionality.
Completed full HVAC system retrofit including furnace and air conditioning equipment. Installed new furnace unit with proper PVC venting configuration, established all electrical connections with dedicated circuit protection, and charged the AC system with R-454B refrigerant to manufacturer specifications. System testing confirmed proper pressures at 184 psig low side and 183 psig high side, with superheat and subcooling readings within acceptable parameters for optimal performance.
Completed recurring commercial heating maintenance visit on residential HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of all components, and examined air filter condition. Filter showed moderate dirt accumulation and discoloration from use but remained serviceable. Inspected ductwork connections, water heater integration, and associated mechanical systems to ensure all equipment operating within normal parameters.
Performed scheduled commercial heating maintenance on rooftop packaged HVAC unit. Conducted comprehensive inspection of refrigerant lines, electrical connections, and evaporator coil assembly, documenting equipment condition with interior and exterior photography. Unit operational with minor dust accumulation noted in air handler compartment.
Completed fall preventative maintenance on commercial Trane rooftop unit per contract agreement. Performed comprehensive system inspection, checked refrigerant temperatures reading 20.2°F, verified filter condition, and documented equipment nameplate information. All components operating within normal parameters with no deficiencies noted at time of service.
Completed new construction HVAC installation including furnace and ductwork system in crawl space. Installed main trunk line with galvanized metal ductwork properly supported from floor joists, along with flexible branch connections for distribution throughout the structure. Applied vapor barrier ground cover for moisture control and installed reflective insulation on foundation walls per code requirements. Exterior work included installation of PVC condensate drain system with proper trap configuration mounted to building exterior, ensuring adequate drainage away from foundation. All ductwork sealed and secured, system ready for startup and commissioning.
Responded to a water leak located under the kitchen sink. Upon inspection, identified the garbage disposal unit as the source of the leak. The existing disposal showed signs of failure at connection points and required replacement. Documented the faulty unit and surrounding plumbing configuration, including the dishwasher drain connection via corrugated hose, PVC discharge piping, and water supply lines. Provided photographic documentation of the defective disposal and cabinet interior for service records.
Completed rough-in installation for new construction HVAC system, including furnace and air conditioning unit placement and ductwork distribution throughout the structure. All equipment was positioned according to specifications and duct runs were installed to ensure proper airflow and system efficiency.
Responded to commercial callback for inoperative condenser fan. Replaced failed condenser fan motor on rooftop HVAC unit and restored system to normal operation. Unit tested and confirmed proper airflow and cooling function upon completion.
Completed spring maintenance on three commercial rooftop units (100, 200, 300) per contract agreement. Performed comprehensive preventive maintenance including filter inspection, coil cleaning, refrigerant line assessment, and electrical connection verification. Units 100 and 200 exhibited heavy debris accumulation on condenser coils and filter screens requiring thorough cleaning to restore proper airflow and heat transfer efficiency. Removed dirt, pollen, and organic matter buildup from mesh panels and top surfaces. Inspected refrigerant lines for proper insulation and secure mounting, noting some algae growth on exterior piping requiring attention. Verified fan operation and checked all mounting hardware for security. All three units tested operational upon completion with improved airflow and no refrigerant leaks detected.
Responded to no cooling complaint on residential HVAC system. Upon arrival, inspected unit and PCB components in basement mechanical area. Diagnosed issue with printed circuit board causing system failure. Replaced defective PCB, verified proper electrical connections, and tested system operation. Unit restored to full cooling capacity with all safety controls functioning properly.
Completed comprehensive spring maintenance on residential HVAC system including Ultra 80 furnace and associated cooling equipment. Performed full system inspection of mechanical components, ductwork, and auxiliary equipment including humidifier and water treatment devices. All units tested and verified operational for upcoming cooling season.
Responded to no cooling complaint in patient room on 3rd floor with thermostat set at 67°F but reading 71°F. Inspected HVAC unit, verified temperature readings with digital thermometer, and examined internal components including blower assembly, wiring connections, and control board. System was found to have operational issues that were addressed, restoring proper cooling function to the space.
Responded to water leak complaint at diffuser. Upon inspection, found evidence of significant condensation and moisture accumulation on blower assembly and surrounding components. Documented conditions with photos showing water droplets on blower housing and moisture staining on ductwork. System appears to have drainage or insulation issue causing condensate to reach diffuser instead of draining properly through designated drain lines.
Completed full HVAC system retrofit installation including new furnace and air conditioning condenser unit. Positioned outdoor AC unit against exterior brick and wood siding with proper clearances, installed refrigerant line set, established electrical disconnect, and mounted unit on stable pad. System installed per manufacturer specifications with all components operational and ready for use pending completion of financing documentation.
Responded to no cooling complaint on rooftop unit. Found system low on refrigerant charge. Recovered remaining refrigerant using recovery cylinder and electronic scale, then performed leak detection with electronic leak detector. Identified leak source, completed necessary repairs, evacuated system, and recharged unit to manufacturer specifications.
Performed concrete floor excavation in basement to provide access for new sewer line installation. Created rectangular opening in concrete foundation, exposing existing underground piping system that required replacement. Removed soil and debris to establish proper depth and clearance for new sewer line routing into the residence, with work area prepared for subsequent pipe installation and connection to main system.
# HVAC Maintenance - Contract Visit - Commercial
Completed scheduled spring preventive maintenance on commercial HVAC unit. Upon inspection, discovered heavy accumulation of dust, dirt, and debris throughout heat exchanger coils and condenser fins, significantly restricting airflow and reducing system efficiency. The buildup was particularly concentrated in the upper coil sections, with substantial particulate matter lodged between the metallic fins.
Performed thorough cleaning of all accessible coil surfaces to restore proper airflow channels and optimize heat transfer capability. Removed accumulated debris from fin structures and mounting components. Documented pre-maintenance conditions showing the extent of contamination and post-cleaning results. System inspected and confirmed operational following maintenance procedures. Unit returned to normal service with improved airflow and heat exchange performance.