Since 1974, Lakes Heating & Air Conditioning has been Canal Fulton, OH’s trusted choice for heating, cooling, and air quality services. Our neighbors in Canal Fulton rely on us for expert HVAC repair, replacement, maintenance, and air quality solutions.
Whether you’re working on a new construction project or need service for your existing home or business, Lakes is the go-to provider for reliable, high-quality HVAC services to keep your space comfortable.
Contact Lakes today for a free estimate or to schedule a service in Canal Fulton, OH.

Emergency Heating Replacement & Repair Services
When winter temperatures in Canal Fulton drop into the 20s, you need a heating system you can rely on. Lakes offers fast, expert heating services to keep you warm during the coldest months. Whether you need a new furnace, boiler, radiant heating, or even a snowmelt system, our team is here to help with installation, replacement, and ongoing maintenance.
We understand that heating emergencies can happen at any time, so our licensed technicians can provide quick repairs to get your system back up and running.
Dependable Air Conditioning Installation & Maintenance
When summer temperatures in Canal Fulton hit the high 80s, you need a cooling system that works. Lakes Heating & Air Conditioning is here to help with AC installation, replacement, and maintenance to keep your home cool even on the hottest days.
We offer various cooling options, including heat pumps and ductless AC systems, to match your needs. Whether replacing an old unit or needing routine maintenance to keep things running smoothly, our team is ready to provide the reliable service you need to stay comfortable all summer.
Commercial HVAC Services Offered
Lakes Heating & Air Conditioning knows how important it is for your business in Canal Fulton to stay comfortable for employees and customers. That’s why we provide reliable commercial HVAC services tailored to your needs. Whether installing a new heating or cooling system, repairing an existing unit, or scheduling regular maintenance, our team ensures your business stays at the perfect temperature year-round.
Geothermal Services in Canal Fulton
Lakes offers energy-efficient geothermal heating and cooling systems for homes and businesses in Canal Fulton. These systems use the Earth’s natural temperature to keep your space comfortable all year.
We provide complete services, including installation and repairs, to keep your geothermal system running smoothly.
Top-Rated Indoor Air Quality Services
At Lakes, we know how important it is to have clean, fresh air in your home or business. We offer indoor air quality services to help you breathe easier.
We provide and maintain air cleaners, scrubbers, and thermostats to keep your air clean and comfortable. We also offer carbon monoxide detectors for safety and humidifiers or dehumidifiers to balance the air’s moisture. Whether you’re dealing with dust, allergens, or dry air, our team has the right solutions to improve indoor air quality.
Choose Lakes Heating & Air Conditioning For Services in Canal Fulton
When you choose Lakes Heating & Air Conditioning, you choose a family-operated business trusted in Canal Fulton since 1974. We offer upfront pricing, so you’ll always know what to expect, and our licensed and insured technicians service all brands with care and professionalism. Let us provide you with the reliable service you deserve.
Contact Lakes Heating & Air Conditioning today to schedule heating, cooling, or indoor air quality services in Canal Fulton, OH.
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Canal Fulton, OH between September 2026 and November 2026. The most recent job was on November 20, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 62 jobs in Canal Fulton, OH in the last 12 months.Recent Jobs and Reviews in Canal Fulton, OH
Canal Fulton, OH at a glance
Job Locations and Reviews
Performed a scheduled maintenance inspection on a rooftop packaged HVAC unit, including the access panels, electrical disconnect, flexible conduit, insulated refrigerant lines, and condensate drain piping. Documented heavy corrosion on the access panel and cabinet, rusted pipe fittings at the refrigerant line entry, and residue at the condensate drain openings, along with weathered, stained roof membrane around the unit base.
Responded to a non-operational gas-fired furnace of undetermined age (estimated 10+ years) and performed a diagnostic evaluation, including combustion analysis with a handheld analyzer, which recorded an elevated Oâ‚‚ level of 8.4% indicating excess air in the combustion process. Further repair or adjustment is recommended to restore proper operation and ensure safe, efficient combustion.
Performed annual maintenance on a 3-year-old gas furnace located in the basement, including a combustion analysis that verified safe, proper operation on natural gas with O2 at 7.31%, CO2 at 7.63%, and CO at 13 ppm. All readings were within acceptable limits, and the system was left operating normally.
Completed a furnace retrofit in the basement, replacing the existing unit with a new upflow furnace set on the concrete slab and connected to the existing supply and return ductwork, including the mounted humidifier. Reconnected the black iron gas piping, secured the electrical connections, and cleared the work area of debris. Equipment is installed and ready for startup and operational verification.
Performed annual heating maintenance on a gas furnace at least 13 years old, including a combustion analysis on natural gas. Readings were within normal operating range: Oâ‚‚ 8.0%, COâ‚‚ 7.3%, CO 9 ppm, stack temperature 104°F, and combustion efficiency of 95.2%. Equipment is operating safely and efficiently.
Performed annual heating maintenance on a 3-year-old gas furnace, inspecting the burner compartment, inducer motor, flue piping, and control wiring for proper operation. Removed and replaced the heavily soiled humidifier pad, clearing accumulated mineral buildup and debris from the humidifier area to restore proper function. Verified the system operated normally through a complete heating cycle.
Responded to install call back for a reported flue pipe leak and inspected the PVC flue and combustion air piping at the furnace, including all couplings, U-bend transitions, and the connection to the horizontal run. No visible cracks, separation, or damage were found at the joints or along the pipe lengths, and the system was left properly secured and in good working condition.
Completed new construction finish of the basement ductwork, installing and securing flexible duct runs to the drop-ceiling supply outlets and connecting the sheet-metal trunk, plenum, and transitions to the system. Installed and terminated the bathroom exhaust duct, completing all connections for proper airflow.
Performed an on-site evaluation for replacement of an existing Lennox upflow gas furnace, inspecting the exposed burner compartment, gas valve and piping, inducer/blower assembly, PVC intake/exhaust venting, and condensate drain. Documented rust staining and corrosion with residue pooling at the base of the cabinet near the burner and gas piping, as well as the existing duct, flexible conduit, and refrigerant line connections, to support the replacement recommendation.
Installed a new split system air handler with supply and return ductwork, including a return air plenum and sheet metal transitions connected to the unit. Completed condensate drainage with PVC piping, a trap and vent, a condensate pump, and a drain pan with a wet switch for overflow protection. Made the electrical and control connections and left the equipment in place and ready for startup.
Performed fall heating maintenance, including inspection of the humidifier assembly with the cover removed to check the evaporator pad, water supply connections, and low-voltage wiring. Conducted combustion analysis with a Testo 327-1 analyzer on natural gas flue gases, recording 5.9% O2, 24 ppm CO, 33 ppm CO air-free, and 34.9% excess air, confirming safe combustion within acceptable operating parameters.
Completed furnace retrofit, upgrading existing 80% efficiency unit to new 97% high-efficiency model in residential utility closet. Installed new condensate drainage system with white PVC piping, including proper pitch and trap configuration for high-efficiency operation. Routed intake and exhaust venting through PVC pipe system, ensuring proper termination and code compliance. Modified and reconnected supply and return ductwork to accommodate new equipment footprint, utilizing flexible duct connections where necessary. Mounted unit in confined space, verified proper clearances, and completed all electrical connections with appropriate disconnect. System tested and operational, achieving proper combustion efficiency and condensate removal.
Completed comprehensive heating maintenance on gas-powered furnace per MVP maintenance protocol. All system components inspected and verified operational, with equipment determined to be in satisfactory condition and not requiring replacement at this time. Service sticker applied to unit documenting maintenance completion.
Completed annual heating maintenance on gas-powered furnace system. Inspected and tested HVAC capacitor (Breeze33 model BZ33-CAPO-440-10, 10μF 440VAC) for proper operation and verified electrical connections. Measured ambient temperature at 72.8°F using calibrated digital thermometer to confirm system performance and thermostat accuracy. All components functioning within normal operating parameters; system ready for heating season.
Completed furnace retrofit installation in basement utility area. New gray metal cabinet furnace unit installed against wall with proper PVC condensate drainage system, white insulated supply ductwork, and black flexible exhaust piping secured with metal clamps. All components properly connected and positioned for optimal operation in accordance with manufacturer specifications.
Completed installation of fire damper and door assembly in new commercial construction space. Installed ceiling-mounted air vent with horizontal slat design and performed preventive maintenance inspection of equipment. All components installed per code requirements and manufacturer specifications, with system verified operational upon completion.
Completed comprehensive furnace tune-up and safety inspection. Performed combustion analysis using calibrated gas analyzer, confirming proper operation with readings of 6.5% O2, 13 PPM CO, and acceptable flue gas temperatures. Cleaned burner assembly, inspected heat exchanger, verified proper airflow, and confirmed all safety controls functioning within manufacturer specifications.
Responded to a continuously running toilet. Upon inspection, found faulty flapper valve and fill valve assembly causing water to flow constantly into the overflow tube. Replaced worn flapper and adjusted float mechanism to restore proper shut-off function, eliminating the running water issue.
Conducted new construction site visit to document installation of commercial rooftop HVAC package unit and associated indoor equipment. Photographed exterior rooftop unit mounted on curb adapter with proper elevation above roof membrane, confirmed unit positioning and clearances meet specifications. Inspected and documented interior air handling equipment mounted to ceiling structure with PVC condensate drainage system and electrical connections in place.
Completed furnace retrofit installation in residential basement utility area. Installed new furnace system with PVC venting and condensate drainage routed through exterior wall, terminating at foundation level with proper pitch and support. Integrated new equipment with existing ductwork system, electrical service panel, and plumbing infrastructure in basement mechanical room. All exhaust and intake venting installed per manufacturer specifications using appropriate PVC materials, penetrating brick exterior wall and secured with proper clearances from grade and building materials. System tested and operational upon completion.