The key to comfort is having a reliable HVAC system. For the Hudson community, you don’t have to worry about low-quality HVAC units because the Lakes Heating & Air Conditioning team is here for you.
With heating, cooling, and indoor air quality options, we can cover every HVAC need. Additionally, we offer HVAC services for new construction projects in Hudson.
Looking for top-rated HVAC services in Hudson, OH? Call (330) 644-7811 and schedule an appointment with Lakes today.

24/7 Emergency HVAC Repair
Some HVAC issues can’t wait for an appointment. Due to this, we offer 24/7 emergency repair for residents in the Hudson community. This helps save on costly damages from prolonged issues.
Signs that you need emergency services include the following:
- Smell of rotten eggs if you have a gas unit
- No hot air from your heating system or no cool air from your cooling system
- Low airflow from your HVAC
- Infrequent cycling from your unit
Quality Heating Installation & Maintenance
With the importance of heat for your Hudson home, we have a wide range of heating services. Our heating installation and maintenance services apply to the following systems:
- Furnaces: With gas and electric furnaces, our services cover any furnace in Hudson.
- Boilers: Due to the Hudson weather, boilers are a reliable heating option for your home.
- Heat pumps: Used year-round, heat pumps are an excellent option for your HVAC needs in Hudson.
- Geothermal units: Designed to be the most efficient option, geothermal units are a great way to keep your energy bill down.
- Radiant heating: Our team offers installation and repair services for radiant space heating units in Hudson.
Call (330) 644-7811 to discuss how Lakes’ heating services can improve your Hudson, OH home.
Exceptional Cooling Installation & Maintenance
The last thing you want is to be stuck in a Hudson summer with no cooling. Our comprehensive cooling services are here for you to ensure you don’t have to sit through sweltering heat with no escape.
Our cooling services include the following:
- Installation and replacement: When it’s time to install a new system, our team will handle the entire process from start to finish. This includes selecting a new system, removing your old one, and installing your new unit.
- Maintenance: To extend the life span of your system, we recommend annual maintenance for your cooling unit.
In addition to traditional cooling, we have ventured out to other areas within cooling. We also offer installation, replacement, and repair services for Hudson residents for alternative systems such as ductless AC and geothermal units.
To receive a free estimate on cooling replacement for your Hudson, OH home, call (330) 644-7811 and schedule an appointment with Lakes today.
Top-Rated Indoor Air Quality Services
One of the most critical parts of your home is the indoor air quality. If your indoor air quality is left unchecked, it can result in higher illness rates, more difficulty breathing, and mold growth. However, our indoor air quality services ensure this doesn’t happen.
Since indoor air quality encompasses a wide range, we have a variety of services designed to help your home. To help with moisture balance, we offer both humidifier and dehumidifier services. On the air side, we have air cleaners that can be installed to increase your air quality.
Call (330) 644-7811 to explore indoor air quality services for your Hudson home with Lakes.
Choose Lakes Heating & Air Conditioning in Hudson, OH
Since 1974, Lakes has been a trusted HVAC expert in the Hudson area. Our background-checked technicians treat every home as their own, guaranteeing unmatched comfort and care. Along with stellar service, we have upfront pricing and financing options to relieve pressure off every job.
For HVAC services in Hudson, OH, contact the Lakes team at (330) 644-7811 and schedule an appointment with Lakes.
Recent Jobs and Reviews in Hudson, OH
Job Locations and Reviews
Completed rough-in installation of bathroom exhaust fans and connected return air pan in basement area of new construction project. Installed flexible ductwork routing through ceiling joists and framed cavities, integrating HVAC components with existing structural framework and coordinating with electrical rough-in. All ventilation connections secured and positioned for final trim-out phase.
Completed new construction HVAC system startup in basement mechanical room after addressing refrigerant line installation issues. Verified proper refrigerant line routing and connections for gray furnace unit, ensured all ductwork connections were secure, and confirmed PVC drainage piping was properly installed. Successfully started up the system, tested all components for proper operation, and verified adequate airflow through the metallic ductwork running throughout the space.
Responded to no-cooling call on 5-year-old AC system. Upon arrival, confirmed unit would not power on. Performed diagnostic inspection of air handler and evaporator coil assembly. Identified tripped breaker at electrical panel as root cause. Reset breaker and verified proper voltage supply to unit. Tested system operation through complete cooling cycle. Confirmed evaporator coil condition, refrigerant line connections, and condensate drain functionality. Unit restored to normal operation with proper airflow and cooling output.
# HVAC Install - A/C & Coil
Completed full air conditioning system replacement including new condenser unit and evaporator coil installation. Removed existing equipment and installed new A/C system with proper refrigerant line connections, condensate drainage integration with existing PVC piping system, and electrical connections. Installed new evaporator coil in the air handler with proper ductwork connections to existing supply and return plenum. Verified all connections were secure, tested system operation, and confirmed proper airflow through the ductwork. System is fully operational and cooling efficiently.
Completed annual cooling system maintenance on five residential HVAC units located in exterior side yard area. Performed comprehensive tune-up procedures on all condensing units, including inspection of fan assemblies, electrical connections, refrigerant levels, and overall system operation. All units, including multiple Lennox branded condensers, were serviced and found to be operating within normal parameters for continued cooling season performance.
Completed new construction HVAC finish installation in residential basement, including Lennox furnace and water heater setup with full ductwork connections and PVC venting system. Performed system commissioning and vacuum testing of refrigerant lines to verify proper evacuation levels, ensuring all equipment met manufacturer specifications and operational standards. All mechanical systems tested and confirmed operational with proper airflow distribution throughout the space.
Completed full HVAC system replacement including outdoor condensing unit and indoor air handler. Installed new Lennox condensing unit on existing concrete pad in side yard with proper clearances from fence and structure. Mounted electrical disconnect box on exterior siding with appropriate conduit routing. Connected refrigerant lines from outdoor unit through exterior wall penetration to indoor air handler located in basement utility area. Installed new air handler with insulated refrigerant line sets, PVC condensate drain piping with proper trap and termination, and integrated flexible ductwork connections to existing distribution system. Verified all electrical connections, refrigerant line integrity, and drainage functionality. System tested and operational.
Performed pre-sale inspection of HVAC system as required by home inspector. Completed comprehensive evaluation of humidifier, furnace, and air conditioning unit. Documented existing conditions including rust and corrosion on ductwork connections and metal components. Provided assessment and repair quote for identified issues to facilitate property transfer requirements.
Responded to no-heat call for commercial furnace unit serving apartment 3A, located in third-floor hallway adjacent to elevator. Upon arrival, inspected electrical disconnect box mounted on exterior brick wall and found deteriorated wiring connections with visible corrosion inside junction box. Documented existing conditions showing compromised wire nuts, exposed conductors including green grounding wires, and weathered enclosure with rust damage affecting electrical integrity. The unit's failure to operate was attributed to faulty electrical supply connections requiring immediate attention to restore power and functionality to the heating system.
Completed callback to install bathroom exhaust fan that was missed during initial new construction installation. Unit was properly mounted between ceiling joists in attic space, connected to flexible metallic ductwork for ventilation, and wired with appropriate electrical connections to complete the installation per building specifications.
Completed installation of range hood venting system for new construction project. Performed preventive maintenance inspection on residential HVAC equipment per manufacturer specifications, verified all systems operating within normal parameters.
Completed HVAC modifications including removal of existing wine chiller unit and reconfiguration of ductwork system. Installed new flexible aluminum ventilation ducting in attic space to accommodate dryer vent and bathroom exhaust fan, routing through existing framing with proper support and clearances. Modified main trunk line with insulated plenum connections and secured all ductwork with appropriate strapping per code requirements. Performed preventive maintenance inspection on heating and cooling equipment, verifying all components are operating within manufacturer specifications.
Conducted new construction site visit to inspect range venting installation and assess remaining work required for completion. Documented ceiling-mounted ventilation components including circular vent fixture installed in framed ceiling area, and verified proper positioning of ductwork routing through structural framing. Coordinated with project contacts regarding final installation requirements and provided photographic documentation of current installation status for review.
Responded to service call for non-operational garage heater and upstairs AC unit. Inspected wall-mounted electric heating unit in garage, verified electrical connections and thermostat operation, and restored proper functionality. Accessed rooftop AC unit via ladder, performed diagnostic evaluation, and completed necessary repairs to return system to normal operation.
Completed comprehensive MVP air conditioning tune-up on 8-year-old outdoor unit. Performed standard maintenance procedures including inspection of refrigerant lines, condensate drain system, and all mechanical components to ensure optimal cooling performance. Unit operating within normal parameters upon completion of service.
Completed spring/summer preventive maintenance on commercial cooling system. Performed comprehensive inspection of heat exchanger coil assembly, refrigerant lines, and blower components. During inspection, identified significant rust and corrosion at base of heat exchanger unit, particularly at tube connection points and lower platform areas. Corrosion exhibits orange-brown deposits with areas of darker discoloration, indicating prolonged moisture exposure affecting critical connection points. Additional rust damage observed along bottom edge of coil assembly spanning width of unit. Documented conditions with photographic evidence. Verified refrigerant line integrity and blower fan housing condition. Advised customer of corrosion findings and recommended monitoring for potential replacement needs to prevent system failure. Unit operational at time of service completion.
Responded to no-heat call for commercial Amana furnace unit. Upon arrival, inspected furnace system and identified issue preventing unit from initiating heating cycle. Examined gas valve assembly, ignition components, and motor controls to diagnose failure to start. Verified proper operation of all safety controls and restored unit to normal heating operation.
Conducted heating system maintenance service and performed combustion analysis using Sauermann analyzer. Readings showed optimal combustion parameters with O2 at 6.69%, CO at 12 ppm, CO2 at 7.97%, and efficiency ratings of 88.8% (eta+) and 98.0% (eta), confirming the unit is operating within manufacturer specifications.
Responded to service call for non-functional thermostat after a power outage. Upon arrival, found White-Rodgers digital thermostat with blank display. Restored power to the thermostat, confirmed proper operation with display showing 70° temperature reading and "AUTO" mode functioning correctly.
Successfully replaced non-functional display control board on wall-mounted mini-split system. Accessed internal components, disconnected existing wiring, and installed new control board with proper wire connections. System tested after installation and verified proper operation of display and all control functions.