Massillon gets up to 22.76 inches of snow annually, it rains for 176.4 days out of the year, and humidity can reach 86% in February! Turn to the professionals to combat this added strain on your HVAC system.
Lakes Heating & Air Conditioning is locally-operated and has provided services to Massillon for over 50 years. We provide top-rated HVAC, new construction services, and indoor air quality solutions.
Schedule an HVAC service in Massillon, OH, by calling Lakes Heating at (330) 536-1276.

Heating & AC Repair
Lakes is committed to helping with all your heating and cooling issues, big or small! With comprehensive HVAC repair, installation, and maintenance services available, our team can help whether you have a faulty furnace, a leaking boiler, or a malfunctioning heat pump.
Some common issues that require professional help are:
- Frequent cycling
- Weird noises or odors
- No heat or air
- Sudden energy cost spikes
Top-Rated Heating Installation & Maintenance
Frigid Ohio winters can quickly dip to subzero temperatures, so an efficient heating system will keep energy costs low and your family toasty warm!
Our heating services include:
- Heating repair: With regular training, we expertly service furnaces, boilers, heat pumps, geothermal units, and radiant heating systems.
- Heating installation & replacement: Price a new heating unit, eliminate the need for repair work, and lower energy costs by 20% to 30%.
- Heating maintenance: With a multipoint inspection and repairs, your heating system will run more soundly, and you can enjoy improved air quality.
Request a heating repair quote in Massillon today by contacting Lakes Heating & Air Conditioning at (330) 536-1276.
Reliable Cooling Installation & Maintenance
Massillon can reach 82.4 degrees at a summer high, so you want your AC to keep your home cool and comfortable. However, let us know if your system is underperforming, leaking, or providing inconsistent temperatures.
Our AC services Include:
- AC installation & replacement: With zoned temperature settings, consider a space-saving and efficient ductless AC. We also install geothermal units.
- AC repair: Let our trusted team resolve your AC issues the first time you call.
- AC maintenance: Regular service can add years to your air conditioner and increase utility savings.
Contact Lakes at (330) 536-1276 to book an AC appointment in Massillon, OH.Â
Expert Indoor Air Quality Services
If you suffer from allergies or a respiratory illness, consider setting up an indoor air quality test. Let our helpful team examine your air and recommend the best filtration products for removing pollutants and irritants.
Our air quality services include:
- Air cleaners: Clean your air and trap pollutants like pet hair, smoke, and dust.
- Humidifiers: Add more moisture to your home and reduce allergy symptoms.
- Dehumidifiers:Remove excess moisture and prevent mildew or mold growth.
To set up an air quality test in your Massillon home, call Lakes at (330) 536-1276.
Choose Lakes Heating & Air Conditioning in Massillon, OH
Our NATE-certified technicians specialize in all brands and are background-checked, fully licensed, and insured. We also offer upfront pricing and flexible financing options to our Massillon customers.
Lakes Heating and Air Conditioning is a brand you can trust. Whether you want a new AC with a smart thermostat or want to correct a faulty heater installation, we are up to the task.
Schedule services with a licensed HVAC technician in Massillon by contacting Lakes Heating at (330) 536-1276.
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Massillon, OH between September 2026 and November 2026. The most recent job was on November 19, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 69 jobs in Massillon, OH in the last 12 months.Recent Jobs and Reviews in Massillon, OH
Massillon, OH at a glance
Job Locations and Reviews
Performed a seasonal tune-up on a 22-year-old basement-installed natural gas furnace, including a combustion analysis with a Bacharach analyzer. Final readings recorded: 9.0% O2, 14 ppm CO, 6.7% CO2, and 89.0% efficiency, indicating the unit is operating within normal combustion parameters.
Performed seasonal heating maintenance on two gas-fired systems (approximately 6 years old), including inspection of a Lennox high-efficiency furnace and its PVC intake/exhaust venting, condensate drain fitting, gas supply piping with shutoff valve, and supply plenum and ductwork. No evidence of frost, rust, or component damage was observed, and the unit was found in serviceable condition.
Performed scheduled preventive maintenance on a 17-year-old natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable parameters, with CO at 10 ppm, Oâ‚‚ at 8.3%, COâ‚‚ at 7.1%, stack temperature of 116°F, and combustion efficiency of 90.8%.
Rebuilt two Mansfield toilets by replacing the fill valves, flappers, and flush lever assemblies and removing the corroded tank hardware. Adjusted water levels and chain slack, then tested both units to confirm proper refill, a complete flush, and a leak-free seal.
Performed seasonal heating maintenance on a 19-year-old gas furnace, including a combustion analysis with a Testo 310 analyzer, which recorded Oâ‚‚ at 9.2% and CO at 5 ppm, indicating safe, within-range combustion and a stable blue flame. Equipment is operating normally with no safety concerns identified.
Performed scheduled heating system maintenance on natural gas-fired equipment, including inspection of primary components and a combustion efficiency test using a calibrated flue gas analyzer. Final readings were within normal operating range: Oâ‚‚ 9.5%, COâ‚‚ 6.5%, CO 5 ppm, stack temperature 103°F, and combustion efficiency 94.7%, confirming safe and efficient operation. The system was left operating properly, and the customer was advised the maintenance plan is due for renewal.
Performed annual tune-up on a three-year-old natural gas furnace, including inspection and cleaning of key heating components and verification of safe, proper operation. Combustion analysis confirmed efficient and safe performance, with readings of 93.4% efficiency, 6.1% Oâ‚‚, 8.4% COâ‚‚, 24 ppm CO, and a 113°F stack temperature. No issues were identified, and the system is operating within normal parameters.
Replaced the failed control board and installed a new Radiant Pro combination pressure/temperature gauge on the hydronic heating system, using thread sealant at the brass fitting. Verified proper gauge readings for system pressure and temperature, and confirmed the board powered up and operated correctly.
Performed an HVAC and indoor air quality assessment following a basement washing machine leak that exposed rust on the return air ductwork. Inspection and photo documentation revealed heavy corrosion and oxidation on the galvanized round elbow, the rectangular plenum seam, and adjacent flexible duct, consistent with prolonged moisture exposure. The compromised return components should be repaired or replaced and the duct system checked for moisture intrusion and contaminants to prevent reduced airflow, air leakage, and degraded indoor air quality.
Performed annual heating system maintenance, including a combustion analysis with a Testo 310 analyzer. Readings showed Oâ‚‚ at 6.9% and CO at 9 ppm, confirming safe, efficient combustion within normal operating parameters. System was left operating properly.
Performed annual maintenance and combustion analysis on an approximately 18-year-old natural gas furnace located in the basement. Flue gas analysis recorded Oâ‚‚ at 10.0%, CO at 12 ppm, COâ‚‚ at 6.2%, stack temperature of 374°F, and combustion efficiency of 79.3%, with CO within acceptable limits and the unit operating safely.
Performed fall heating maintenance on two furnaces, including combustion analysis of each unit using a calibrated flue gas analyzer on natural gas. One unit tested at 6.51% O2, 8.08% CO2, and 44 ppm CO, and the other at 10.82% O2, 5.67% CO2, and 7 ppm CO, with all CO levels within acceptable limits. Combustion readings were documented to verify safe, proper burner operation heading into the heating season.
Performed annual maintenance on a 20+ year-old gas-fired furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings on natural gas measured Oâ‚‚ at 5.2%, CO at 39 ppm, COâ‚‚ at 8.8%, and combustion efficiency at 96.1%, confirming the unit is operating within acceptable parameters.
Inspected the reported leaking pressure gauge at the plumbing manifold assembly and verified the brass pressure-reducing valve and inline fittings. Identified moisture at the gauge and adjacent brass fittings, with a hairline crack in the panel edge near the lower cutout. Documented the assembly, confirmed no active leaks, corrosion, or damage at the manifold, PEX lines, or filter housing, and recommended gauge replacement to restore proper pressure monitoring.
Performed a complete tune-up on an 8-year-old Lennox cooling system and furnace, including inspection and operational testing of both units. Conducted combustion analysis on the furnace using a calibrated flue gas analyzer, with readings recorded for O2 (11.45%), CO (21 ppm), and CO2 (5.32%) on natural gas, confirming safe combustion levels and proper operation.
Performed seasonal heating maintenance on a natural gas furnace of unknown age, including a combustion analysis. Readings recorded were 9.3% O2, 6.5% CO2, 81.4% efficiency, and 168 ppm CO, indicating a lean, elevated-excess-air burn with CO above the typical acceptable range. Findings documented for further evaluation of burner and heat exchanger condition.
Performed annual heating maintenance on a 20-year-old natural gas furnace, including inspection of the heat exchanger, burners, and ignition components, and cleaning as needed to ensure safe, reliable operation. Combustion analysis confirmed the unit is operating within normal parameters, with CO at 3 ppm, O2 at 6.9%, CO2 at 7.9%, and combustion efficiency of 96.0%. System tested and left in proper working order.
Completed annual heating maintenance on a 7-year-old residential furnace. Performed comprehensive system inspection, cleaned and tested all components, and verified combustion efficiency at 95.5% with CO levels reading 26 ppm and Oâ‚‚ at 7.6% using calibrated gas analyzer. All safety controls and operational parameters confirmed within manufacturer specifications; unit operating properly with no repairs required at this time.
Performed routine maintenance on an 8-year-old gas furnace. Conducted combustion analysis using Bacharach analyzer, which showed oxygen levels at 8.1%, carbon monoxide at 25 ppm, and carbon dioxide at 7.2%. All readings were within acceptable operating parameters for safe and efficient furnace operation.
Completed scheduled maintenance on an 8-year-old gas furnace system. Performed comprehensive inspection of all system components, including ductwork, air handler, and heating elements. Verified proper airflow through supply ductwork with reflective insulation and confirmed 16x25x1 filter specifications. Measured supply air temperature at 126.8°F, indicating normal heating operation and proper heat exchanger function.