Black Friday Deals are Live! Click Here to Claim Your Offers!
Black Friday Deals are Live! Click Here to Claim Your Offers!

Heating, Cooling & Air Quality Services in Akron, OH

Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.

Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.

Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Air conditioning unit outside an Ohio home

Emergency HVAC Repair

When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:

  • Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
  • Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
  • Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
  • Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.

Comprehensive Heating Services

With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.

Thorough Cooling Installation & Maintenance

Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.

Professional Indoor Air Quality Services

Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.

Why Trust Lakes Heating & Air Conditioning?

We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.

Reach out to the Lakes Heating & Air Conditioning for your free estimate today!

 

Recent Jobs and Reviews in Akron, OH

Akron, OH at a glance

Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in November 2026.

The most recent job was on November 23, 2026.

Lakes Heating, Air Conditioning & Plumbing INC has completed 933 jobs in Akron, OH in the last 12 months.

Job Locations and Reviews

Akron, OH - Responded to a no-heat call on a 20-year-old gas furnace presenting with short-cycling, where the unit would run briefly and then shut down. Performed a combustion analysis with a Testo 310 analyzer, recording Oâ‚‚ at 8.7% and CO at 6 ppm, indicating CO levels within safe limits and a lean combustion profile.
Nick D.
Nick D. Checked in
Responded to a no-heat call on a 20-year-old gas furnace presenting with short-cycling, where the unit would run briefly and then shut down. Performed a combustion analysis with a Testo 310 analyzer, recording Oâ‚‚ at 8.7% and CO at 6 ppm, indicating CO levels within safe limits and a lean combustion profile.
Akron, OH 44319
Akron, OH - Performed annual heating tune-up on a 20-year-old Lennox natural gas furnace, including combustion analysis with a Bacharach analyzer. Flue gas readings recorded at O2 8.8%, CO 5 ppm, CO2 5.8%, with CO within safe limits.
Brynn L.
Brynn L. Checked in
Performed annual heating tune-up on a 20-year-old Lennox natural gas furnace, including combustion analysis with a Bacharach analyzer. Flue gas readings recorded at O2 8.8%, CO 5 ppm, CO2 5.8%, with CO within safe limits.
Akron, OH 44306
Akron, OH - Performed a seasonal tune-up and heating maintenance inspection on a 9-year-old gas furnace, which was operating properly at time of service. Conducted a combustion analysis with a Bacharach analyzer on natural gas, recording O2 at 5.3%, CO at 39 ppm, and CO2 at 8.8%, to verify safe and efficient burner operation prior to the heating season.
Maddex H.
Maddex H. Checked in
Performed a seasonal tune-up and heating maintenance inspection on a 9-year-old gas furnace, which was operating properly at time of service. Conducted a combustion analysis with a Bacharach analyzer on natural gas, recording O2 at 5.3%, CO at 39 ppm, and CO2 at 8.8%, to verify safe and efficient burner operation prior to the heating season.
Akron, OH 44319
Akron, OH - Inspected the power-vent gas water heater reported as leaking, including the PVC exhaust and blower assembly, supply and distribution piping, brass fittings and valves, and the expansion tank. No visible rust, frost, or damage was observed in the photographed installation.
Triston Y.
Triston Y. Checked in
Inspected the power-vent gas water heater reported as leaking, including the PVC exhaust and blower assembly, supply and distribution piping, brass fittings and valves, and the expansion tank. No visible rust, frost, or damage was observed in the photographed installation.
Akron, OH 44319
Installed a new 40-gallon short Bradford White natural gas water heater, connecting the copper water supply lines, expansion tank, and yellow flexible gas connector with black iron piping to the gas control valve. Vented the unit through a metal flue pipe into the existing galvanized vent ductwork, and confirmed all connections were secure.
Installed a new 40-gallon short Bradford White natural gas water heater, connecting the copper water supply lines, expansion tank, and yellow flexible gas connector with black iron piping to the gas control valve. Vented the unit through a metal flue pipe into the existing galvanized vent ductwork, and confirmed all connections were secure.
Triston Y.
Triston Y. Checked in
Installed a new 40-gallon short Bradford White natural gas water heater, connecting the copper water supply lines, expansion tank, and yellow flexible gas connector with black iron piping to the gas control valve. Vented the unit through a metal flue pipe into the existing galvanized vent ductwork, and confirmed all connections were secure.
Akron, OH 44313
Akron, OH - Performed scheduled heating maintenance on a gas-fired furnace and conducted a combustion analysis using a calibrated flue gas analyzer. Readings recorded were O2 at 9.06%, CO2 at 6.65%, and CO at 96 ppm, with the elevated CO level noted for follow-up evaluation of burner combustion and heat exchanger condition.
Jake T.
Jake T. Checked in
Performed scheduled heating maintenance on a gas-fired furnace and conducted a combustion analysis using a calibrated flue gas analyzer. Readings recorded were O2 at 9.06%, CO2 at 6.65%, and CO at 96 ppm, with the elevated CO level noted for follow-up evaluation of burner combustion and heat exchanger condition.
Akron, OH 44321
Akron, OH - Performed scheduled heating maintenance on an 11-year-old furnace, including a combustion analysis with a Testo 310 analyzer. Readings recorded Oâ‚‚ at 7.2% and CO at 8 ppm, confirming the unit is operating within safe CO limits.
Nick D.
Nick D. Checked in
Performed scheduled heating maintenance on an 11-year-old furnace, including a combustion analysis with a Testo 310 analyzer. Readings recorded Oâ‚‚ at 7.2% and CO at 8 ppm, confirming the unit is operating within safe CO limits.
Akron, OH 44310
Akron, OH - Performed a furnace clean and check, including a combustion analysis on the natural gas appliance during a run cycle. Readings recorded: Oâ‚‚ 7.5%, CO 54 ppm, COâ‚‚ 7.6%, and combustion efficiency of 81.4%.
Brynn L.
Brynn L. Checked in
Performed a furnace clean and check, including a combustion analysis on the natural gas appliance during a run cycle. Readings recorded: Oâ‚‚ 7.5%, CO 54 ppm, COâ‚‚ 7.6%, and combustion efficiency of 81.4%.
Akron, OH 44306
Akron, OH - Responded to a complaint of excessive heat in the basement during furnace operation and performed a combustion analysis on the natural gas furnace. Flue gas readings showed 5.7% O2, 33.3% excess air, 29 ppm CO, and 40 ppm CO air-free, confirming safe and efficient combustion. The unit's service history card was also reviewed, showing prior filter changes.
Zack W.
Zack W. Checked in
Responded to a complaint of excessive heat in the basement during furnace operation and performed a combustion analysis on the natural gas furnace. Flue gas readings showed 5.7% O2, 33.3% excess air, 29 ppm CO, and 40 ppm CO air-free, confirming safe and efficient combustion. The unit's service history card was also reviewed, showing prior filter changes.
Akron, OH 44319
Performed a tune-up on a 20+ year-old gas-fired heating system, including a combustion analysis of the flue gases with a Testo 327-1 analyzer. Readings showed 9.1% O2, 68.4% excess air, 32 ppm CO, and 57 ppm air-free CO, with the equipment in a confined mechanical space with galvanized ductwork and a gas supply line with shutoff valve.
Performed a tune-up on a 20+ year-old gas-fired heating system, including a combustion analysis of the flue gases with a Testo 327-1 analyzer. Readings showed 9.1% O2, 68.4% excess air, 32 ppm CO, and 57 ppm air-free CO, with the equipment in a confined mechanical space with galvanized ductwork and a gas supply line with shutoff valve.
Zack W.
Zack W. Checked in
Performed a tune-up on a 20+ year-old gas-fired heating system, including a combustion analysis of the flue gases with a Testo 327-1 analyzer. Readings showed 9.1% O2, 68.4% excess air, 32 ppm CO, and 57 ppm air-free CO, with the equipment in a confined mechanical space with galvanized ductwork and a gas supply line with shutoff valve.
Akron, OH 44319
Akron, OH - Responded to a no-heat call on a gas-fired boiler and performed a combustion analysis on the flue gases using a Testo 327-1 analyzer. Readings showed 82.6% efficiency, 10.4% excess air, 2.2% O2, and 87 PPM CO, with the unit's cabinet showing visible rust and peeling paint.
Zack W.
Zack W. Checked in
Responded to a no-heat call on a gas-fired boiler and performed a combustion analysis on the flue gases using a Testo 327-1 analyzer. Readings showed 82.6% efficiency, 10.4% excess air, 2.2% O2, and 87 PPM CO, with the unit's cabinet showing visible rust and peeling paint.
Akron, OH 44319
Performed heating maintenance on three 9-year-old units, including combustion analysis with a calibrated flue gas analyzer on natural gas. Readings recorded O2 at approximately 8.4–8.8%, CO2 at approximately 6.8–7.0%, and CO at 6 ppm, indicating clean combustion with carbon monoxide well within acceptable limits.
Performed heating maintenance on three 9-year-old units, including combustion analysis with a calibrated flue gas analyzer on natural gas. Readings recorded O2 at approximately 8.4–8.8%, CO2 at approximately 6.8–7.0%, and CO at 6 ppm, indicating clean combustion with carbon monoxide well within acceptable limits.
Jake T.
Jake T. Checked in
Performed heating maintenance on three 9-year-old units, including combustion analysis with a calibrated flue gas analyzer on natural gas. Readings recorded O2 at approximately 8.4–8.8%, CO2 at approximately 6.8–7.0%, and CO at 6 ppm, indicating clean combustion with carbon monoxide well within acceptable limits.
Akron, OH 44333
Akron, OH - Performed seasonal tune-up and cleaning on a 15-year-old natural gas furnace in preparation for the heating season. Conducted a combustion analysis at the unit, recording O2 at 7.3%, CO at 7 ppm, CO2 at 7.7%, and steady-state efficiency of 82.7%, with CO within safe limits.
Brynn L.
Brynn L. Checked in
Performed seasonal tune-up and cleaning on a 15-year-old natural gas furnace in preparation for the heating season. Conducted a combustion analysis at the unit, recording O2 at 7.3%, CO at 7 ppm, CO2 at 7.7%, and steady-state efficiency of 82.7%, with CO within safe limits.
Akron, OH 44319
Completed furnace retrofit, replacing the existing unit with a new gas furnace in the utility space and connecting it to the existing electrical disconnect. Installed PVC combustion air/vent piping with exterior termination through the wall, and routed the condensate drain and line set from the equipment to the outdoor condenser.
Completed furnace retrofit, replacing the existing unit with a new gas furnace in the utility space and connecting it to the existing electrical disconnect. Installed PVC combustion air/vent piping with exterior termination through the wall, and routed the condensate drain and line set from the equipment to the outdoor condenser.
Denver H.
Denver H. Checked in
Completed furnace retrofit, replacing the existing unit with a new gas furnace in the utility space and connecting it to the existing electrical disconnect. Installed PVC combustion air/vent piping with exterior termination through the wall, and routed the condensate drain and line set from the equipment to the outdoor condenser.
Akron, OH 44319
Installed customer-supplied Pioneer mini split outdoor condenser on wall-mounted metal brackets against a shipping container, with insulated refrigerant line set, flexible electrical conduit, and a wall-mounted disconnect box connected to the unit. Line set and conduit were secured with zip ties and routed along the wall with a cover, and the installation showed no visible damage.
Installed customer-supplied Pioneer mini split outdoor condenser on wall-mounted metal brackets against a shipping container, with insulated refrigerant line set, flexible electrical conduit, and a wall-mounted disconnect box connected to the unit. Line set and conduit were secured with zip ties and routed along the wall with a cover, and the installation showed no visible damage.
Denver H.
Denver H. Checked in
Installed customer-supplied Pioneer mini split outdoor condenser on wall-mounted metal brackets against a shipping container, with insulated refrigerant line set, flexible electrical conduit, and a wall-mounted disconnect box connected to the unit. Line set and conduit were secured with zip ties and routed along the wall with a cover, and the installation showed no visible damage.
Akron, OH 44319
Performed scheduled heating maintenance on a gas-fired boiler and conducted combustion analysis using a Testo 327-1 analyzer on natural gas flue gas. Initial readings showed 82.9% excess air, 10.1% O2, 27 ppm CO, and 52 ppm air-free CO; after adjustment, readings improved to 72.5% excess air, 9.4% O2, 13 ppm CO, and 24 ppm air-free CO, all within acceptable limits.
Performed scheduled heating maintenance on a gas-fired boiler and conducted combustion analysis using a Testo 327-1 analyzer on natural gas flue gas. Initial readings showed 82.9% excess air, 10.1% O2, 27 ppm CO, and 52 ppm air-free CO; after adjustment, readings improved to 72.5% excess air, 9.4% O2, 13 ppm CO, and 24 ppm air-free CO, all within acceptable limits.
Zack W.
Zack W. Checked in
Performed scheduled heating maintenance on a gas-fired boiler and conducted combustion analysis using a Testo 327-1 analyzer on natural gas flue gas. Initial readings showed 82.9% excess air, 10.1% O2, 27 ppm CO, and 52 ppm air-free CO; after adjustment, readings improved to 72.5% excess air, 9.4% O2, 13 ppm CO, and 24 ppm air-free CO, all within acceptable limits.
Akron, OH 44313
Inspected the water heater venting and found the vent piping corroded and rotted out at the original wall penetration, requiring replacement; an existing chimney liner was confirmed to be in place. Staged new stainless steel vent components, including elbow, straight sections, reducer, and wall thimble hardware, for installation per the manufacturer's horizontal venting and thimble installation procedures with proper slope and support.
Inspected the water heater venting and found the vent piping corroded and rotted out at the original wall penetration, requiring replacement; an existing chimney liner was confirmed to be in place. Staged new stainless steel vent components, including elbow, straight sections, reducer, and wall thimble hardware, for installation per the manufacturer's horizontal venting and thimble installation procedures with proper slope and support.
Nick D.
Nick D. Checked in
Inspected the water heater venting and found the vent piping corroded and rotted out at the original wall penetration, requiring replacement; an existing chimney liner was confirmed to be in place. Staged new stainless steel vent components, including elbow, straight sections, reducer, and wall thimble hardware, for installation per the manufacturer's horizontal venting and thimble installation procedures with proper slope and support.
Akron, OH 44313
Inspected the existing gas furnace installation and documented its current condition for replacement. With the access panel removed, the burner assembly, inducer motor, control board, pressure switch, and blower compartment were exposed and photographed, along with the PVC intake/exhaust piping, galvanized supply plenum and ductwork, and associated gas, electrical, and condensate connections. No evidence of frost, rust, or major damage was observed, and the unit's data and warning labels were documented to support equipment selection for the replacement estimate.
Inspected the existing gas furnace installation and documented its current condition for replacement. With the access panel removed, the burner assembly, inducer motor, control board, pressure switch, and blower compartment were exposed and photographed, along with the PVC intake/exhaust piping, galvanized supply plenum and ductwork, and associated gas, electrical, and condensate connections. No evidence of frost, rust, or major damage was observed, and the unit's data and warning labels were documented to support equipment selection for the replacement estimate.
Justin B.
Justin B. Checked in
Inspected the existing gas furnace installation and documented its current condition for replacement. With the access panel removed, the burner assembly, inducer motor, control board, pressure switch, and blower compartment were exposed and photographed, along with the PVC intake/exhaust piping, galvanized supply plenum and ductwork, and associated gas, electrical, and condensate connections. No evidence of frost, rust, or major damage was observed, and the unit's data and warning labels were documented to support equipment selection for the replacement estimate.
Akron, OH 44301
Replaced the existing furnace and hot water tank (HWT) as part of a weatherization assistance program upgrade, including associated venting and piping connections to the new equipment in the basement utility space. Installation was completed with the equipment secured and connected to the existing ductwork and water, gas, and electrical services.
Replaced the existing furnace and hot water tank (HWT) as part of a weatherization assistance program upgrade, including associated venting and piping connections to the new equipment in the basement utility space. Installation was completed with the equipment secured and connected to the existing ductwork and water, gas, and electrical services.
Denver H.
Denver H. Checked in
Replaced the existing furnace and hot water tank (HWT) as part of a weatherization assistance program upgrade, including associated venting and piping connections to the new equipment in the basement utility space. Installation was completed with the equipment secured and connected to the existing ductwork and water, gas, and electrical services.
Akron, OH 44320
AKRON, OH - Responded to a no-heat call on a gas-fired system over 10 years old and performed combustion analysis with a Testo 310 analyzer to evaluate flue gas readings and appliance operation. Documented analyzer results as part of the diagnostic process.
Nick D.
Nick D. Checked in
Responded to a no-heat call on a gas-fired system over 10 years old and performed combustion analysis with a Testo 310 analyzer to evaluate flue gas readings and appliance operation. Documented analyzer results as part of the diagnostic process.
AKRON, OH 44319

Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover the Lakes Heating & Air Conditioning Difference

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Trusted in Your Home & Business Since 1974

For nearly 50 years, Lakes has been trusted by Northeast Ohio home and business owners.

Fully Licensed & Insured

Our team of experts has the skill and training to deliver the highest quality services every time.

Honest Work Ethic

The Lakes Heating & Air Conditioning team is dedicated to ensuring honest and expert service every time.

Commitment to Integrity & Professionalism

Our technicians are committed to high-standard work, integrity, and professionalism with every service.

Satisfaction Guarantee

We are dedicated to ensuring customers 100% satisfaction with every heating and cooling service we perform.

Financing Available

We offer financing options to our customers to ensure that our services are always accessible and affordable.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Installed complete heating and cooling system in older house, Not an easy install. They did a fantastic job. Workers were polite and professional. I wish all contractors operated the way they do. Highly recommend them.

Mark F.

Mark F.

Love this family owned company. They take great care, offer real advice to keep heating and air running efficiently, fair pricing and great service from booking appointments to the techs that come to service your unit. Have used them for a long time and never been…

Kimberly R.

Kimberly R.

Best service, honest, fair prices! I called Lakes because of their reputation in the community, and I was not disappointed. My furnace went out during a cold snap of subzero temperatures, and Lakes got a new furnace in my home the very next day for a…

Michelle W.

Michelle W.

I am new to the area and shortly after moving into our new home, we learned the zone heating was not working. I received a couple of quotes. Lake's Heating was thorough and quoted us only for work that was required to repair the issue --…

Gina M.

Gina M.

Call the Lakes team; you will be very glad you did! Everyone I dealt with was professional in every aspect. They performed a major overhaul of our furnace at a significantly lower cost than a competitor quoted. In a service business that knows you have sought…

Scott R.

Scott R.