Midwestern weather can be extreme and unpredictable. Whether your broken air conditioner is running up your bill or your aging furnace is banging at night, Lakes Heating & Air Conditioning has the expertise to keep your heating, cooling, and air quality systems working reliably.
Our licensed and insured technicians service all brands if your system needs repair, and we provide free estimates when you’re ready to install a replacement. Our new construction installations guarantee builders control from the design stage to the finished home. Offering solutions for Akron homes since 1974, you can trust both our experience and our upfront pricing.
Take control of your home comfort! Contact us to schedule installation and repair services in Akron today!

Emergency HVAC Repair
When minor problems become big, they cost more time and money. If you notice these signs, it’s time for immediate repair:
- Foul smells: Odors can indicate that you need a technician to clean and sanitize your air ducts.
- Reduced airflow: Lack of or no airflow may mean blocked air ducts or other ventilation problems.
- Leaks and water damage: A clogged drain line or uneven installation can lead to leaks from your cooling system.
- Loud knocking sounds: Odd noises often indicate that your system is nearing the end of its functionality.
Comprehensive Heating Services
With an average January low of around 20 degrees in Akron, you don’t want your heating system to break down on a freezing night. Whether you are installing a geothermal unit or radiant heating, or need repair work for your furnace, boiler, or heat pump, the Lakes Heating & Air Conditioning technicians have what you need to keep your home warm all winter. An efficient system also means lower energy bills, so you don’t have to choose between affordability and comfort.
Thorough Cooling Installation & Maintenance
Our team can promptly service your system so you can get back to your summer plans. Lakes Heating & Air Conditioning is here to repair your current system or replace it with a more energy-efficient one. Not every home has the exact cooling needs, and our ductless AC offers flexibility for your home’s unique layout. Our geothermal units work with renewable energy to significantly reduce your monthly bill.
Professional Indoor Air Quality Services
Is the tree pollen forecast high in Akron today? Even with the filters of an excellent heating and cooling system, your home is susceptible to mold, bacteria, and other particles that can impact your health and allergies. Air cleaners from Lakes Heating & Air Conditioning improve your air quality and peace of mind so you can breathe easier. Our humidifiers and dehumidifiers give you total control of your home’s comfort no matter what the weather’s like outside.
Why Trust Lakes Heating & Air Conditioning?
We know our community. Whether it’s meeting your heating, cooling, and air quality needs or sponsoring local scholarships and sports teams, Lakes Heating & Air Conditioning is a reputable family-operated part of Akron. Trust AACA-accredited service from our background-checked team. We’re here for our military, veteran, and senior neighbors with special discounts. Our technicians keep your HVAC system running while our upfront pricing and financing options keep your budget in mind.
Reach out to the Lakes Heating & Air Conditioning for your free estimate today!
Lakes Heating, Air Conditioning & Plumbing INC has completed 20 jobs in Akron, OH in October 2026. The most recent job was on October 23, 2026. Lakes Heating, Air Conditioning & Plumbing INC has completed 788 jobs in Akron, OH in the last 12 months.Recent Jobs and Reviews in Akron, OH
Akron, OH at a glance
Job Locations and Reviews
Responded to a leaking tanked gas water heater complaint and inspected the Rheem Performance unit, including the supply connections, T&P discharge piping, vent connector, and burner compartment. Noted rust residue and debris at the base of the unit and documented the condition with photos for further evaluation and recommendations.
Performed a scheduled heating maintenance visit and conducted a flue gas combustion analysis on the natural gas-fired appliance using a Testo digital analyzer. Readings recorded 7.2% O2, 46.7% excess air, 34 ppm CO, and 52 ppm air-free CO, confirming combustion performance and flue gas safety levels were within acceptable operating range. Equipment age was undetermined, and the customer was advised that the maintenance plan is due for renewal.
Retrofitted the existing gas furnace with a new AC system, installing the evaporator coil on the supply plenum and connecting it to the condensing unit with refrigerant lines. Sealed and secured the supply duct transitions and plenum connections, and verified gas line connections, venting, and condensate drainage. Commissioned the complete system, confirming proper airflow, refrigerant charge, and heating and cooling operation.
Installed a new gas-fired boiler with a stainless steel vent connection to the ceiling, along with new soldered copper supply and return piping, isolation ball valves, a pressure gauge, and a circulator pump with digital display. Mounted an expansion tank and added drain fittings and flexible conduit for electrical connections. The completed installation is clean, properly supported, and free of visible leaks, rust, or damage.
Responded to a no-heat call on a 2-year-old gas furnace and performed a full system inspection, including the control board, wiring harness, gas valve, and burner assembly. Noted soot and carbon residue on the burner compartment and gas piping, and verified the control board status indicator for diagnostic fault codes. Cleaned the burner area and checked all connections to restore proper furnace operation.
Replaced flexible ductwork with rigid hard pipe on all return air runs in the framed ceiling and wall cavities to improve airflow performance and system durability. Secured and sealed all transitions and connections to boots and collars to ensure proper return air delivery under the new construction warranty.
Performed an on-site assessment for a commercial multi-zone mini split system installation consisting of three outdoor units and nine indoor units. Inspected the existing rooftop mounting area and Mitsubishi Electric condensing units, and evaluated the available electrical service, including a GE A Series panelboard with labeled circuits for the 2nd floor commons and rooftop AC unit, to determine breaker capacity and circuit requirements. Documented existing equipment placement, support blocking, and refrigerant line routing conditions to support system sizing and installation planning.
Responded to a no-heat call on a 6-year-old furnace that failed to start when the thermostat called for heat. Performed diagnostics on the system, including inspection of the integrated furnace control board and low-voltage thermostat wiring connections, and documented the unit's model and serial numbers along with the replacement part information. The control board showed no visible burns, corrosion, or physical damage.
Performed annual heating maintenance on a 3-year-old natural gas furnace, including combustion analysis with a calibrated flue gas analyzer. Readings showed O2 at 8.43%, CO2 at 7.00%, and CO at 37 ppm, indicating safe combustion levels and proper burner operation. System was left operating normally.
Performed annual gas furnace maintenance, including inspection of the inducer/collector assembly, gas piping and valve, wiring harness, PVC vent and condensate drain connections, and interior cabinet components, with no breakage, rust, or leaks observed. Conducted a combustion analysis on natural gas, with flue gas readings of 8.1% O2, 4 ppm CO, and 7 ppm air-free CO confirming safe, efficient combustion within normal operating parameters.
Performed fall heating maintenance on the natural gas furnace, including a flue gas combustion analysis showing 6.9% O2, 43.8% excess air, and 11 ppm CO (16 ppm air-free), all within acceptable operating limits. Inspected and serviced the return air filter, which showed moderate dust loading, to maintain proper airflow and system efficiency. Unit operation verified with no visible rust, frost, or damage observed.
Responded to a no-heat call on a Comfort-Aire gas furnace reported to have a buzzing noise and failure to cycle, with a suspected blower motor or control board fault. Inspected the inducer assembly, pressure switch, gas valve, and burner compartment, then restored operation with stable burner flame established. Verified performance with a combustion analysis on natural gas, recording 5.6% O2, 32.5% excess air, 27 ppm CO, and 37 ppm air-free CO, all within acceptable limits.
Responded to a no-cool call on a 16-year-old gas furnace and performed a combustion analysis on the flue gas using a Testo 327-1 analyzer. Readings showed 6.0% O2, 35.8% excess air, 7 ppm CO, and 10 ppm air-free CO, all within acceptable operating limits for natural gas combustion.
Performed fall heating maintenance on a natural gas furnace, including a combustion analysis to verify safe and efficient operation. Flue gas readings were within acceptable range, with O2 at 8.2%, CO2 at 7.1%, CO at 9 ppm, and steady-state efficiency of 88.1%. System operating normally at completion of service.
Performed scheduled heating maintenance on a gas-fired furnace, including inspection of the unit and verification of proper operation. Conducted a combustion analysis using a digital analyzer on natural gas, recording O2 at 7.32%, CO at 7 ppm, and CO2 at 7.62%, with CO levels well within safe limits and indicating clean, stable combustion. No deficiencies were noted and the system was left operating normally.
Performed a descale service on the power-vented Rheem tank water heater, flushing mineral and sediment buildup from the tank and discharging the flush water to the adjacent floor drain. Following the service, the unit, venting, and electrical connections were inspected, and no leaks, corrosion, or visible damage were found.
Installed shutoff valves on the gas piping serving a multi-meter manifold in the basement utility area, connecting flexible gas lines with brass fittings and red-handled isolation valves to each meter. Verified secure connections and proper valve operation at each meter location, with piping routed overhead to the meter bank.
Performed a scheduled commercial heating maintenance visit, inspecting the return air ductwork and verifying the 16x25x1 filter installation, which was found to be dated 10/19/21 and in need of replacement. Measured duct surface temperature at 126.3°F with a digital pocket thermometer to confirm heating operation, and checked the foil-taped duct seams, with no damage, frost, or rust observed.
Performed seasonal fall heating maintenance on a natural gas furnace, including a combustion analysis using a Bacharach analyzer to verify safe and efficient operation. Flue gas readings were within acceptable parameters, with O2 at 10.5%, CO at 14 ppm, CO2 at 5.9%, and steady-state efficiency of 96.8%, confirming proper combustion and heat exchanger performance.
Performed seasonal heating maintenance on a 22-year-old basement-installed natural gas furnace. Completed a flue gas combustion analysis with a Testo 327-1, recording 9.2% O2, 69.7% excess air, 2 ppm CO, and 4 ppm air-free CO, all within safe operating limits and confirming proper combustion performance. The unit is operating normally, and the customer is due for maintenance plan renewal.